drivers: thermal: tsens: respect thermal_device_mode in threshold irq reporting
Subsystems (3)
PATCH 1/1 drivers: thermal: tsens: respect thermal_device_mode in threshold irq reporting
'echo disabled > .../thermal_zoneX/mode' will disable the thermal core's polling mechanism to check for threshold trips. However, tsens supports an interrupt mechanism to receive notification of trips, implemented in commit 634e11d5b450 ("drivers: thermal: tsens: Add interrupt support"). This is used sometimes to run performance test cases.
Currently the thermal zone mode that's set by userspace is not checked before propagating threshold trip events from IRQs. Let's fix this to restore the abilty to disable thermal throttling at runtime.
====================
Tested on MSM8939 running 5.16.0. This platform has 8 cores; the first four thermal zones control cpu0-3 and the last zone is for the other four CPUs together.
for f in /sys/class/thermal/thermal_zone*; do
echo "disabled" > $f/mode
echo $f | paste - $f/type $f/mode
done
/sys/class/thermal/thermal_zone0 cpu0-thermal disabled/sys/class/thermal/thermal_zone1 cpu1-thermal disabled/sys/class/thermal/thermal_zone2 cpu2-thermal disabled/sys/class/thermal/thermal_zone3 cpu3-thermal disabled/sys/class/thermal/thermal_zone4 cpu4567-thermal disabled
With mitigation thresholds at 75 degC and load running, we can now cruise past temp=75000 without CPU throttling kicking in.
watch -n 1 "grep '' /sys/class/thermal/*/temp
/sys/class/thermal/*/cur_state /sys/bus/cpu/devices/cpu*/cpufreq/cpuinfo_cur_freq"
/sys/class/thermal/thermal_zone0/temp:82000 /sys/class/thermal/thermal_zone1/temp:84000 /sys/class/thermal/thermal_zone2/temp:87000 /sys/class/thermal/thermal_zone3/temp:84000 /sys/class/thermal/thermal_zone4/temp:84000 /sys/class/thermal/cooling_device0/cur_state:0 /sys/class/thermal/cooling_device1/cur_state:0 /sys/bus/cpu/devices/cpu0/cpufreq/cpuinfo_cur_freq:1113600 /sys/bus/cpu/devices/cpu1/cpufreq/cpuinfo_cur_freq:1113600 /sys/bus/cpu/devices/cpu2/cpufreq/cpuinfo_cur_freq:1113600 /sys/bus/cpu/devices/cpu3/cpufreq/cpuinfo_cur_freq:1113600 /sys/bus/cpu/devices/cpu4/cpufreq/cpuinfo_cur_freq:800000 /sys/bus/cpu/devices/cpu5/cpufreq/cpuinfo_cur_freq:800000 /sys/bus/cpu/devices/cpu6/cpufreq/cpuinfo_cur_freq:800000 /sys/bus/cpu/devices/cpu7/cpufreq/cpuinfo_cur_freq:800000
--- drivers/thermal/qcom/tsens.c | 15 +++++++++------ 1 file changed, 9 insertions(+), 6 deletions(-)
drivers/thermal/qcom/tsens.c +9 -6
@@ -509,13 +509,16 @@ static irqreturn_t tsens_irq_thread(int irq, void *data)spin_unlock_irqrestore (&priv->ul_lock, flags);if (trigger) { -dev_dbg (priv->dev,"[%u] %s: TZ update trigger (%d mC)\n" , - hw_id, __func__, temp); -thermal_zone_device_update (s->tzd, -THERMAL_EVENT_UNSPECIFIED ); +if (s->tzd->mode ==THERMAL_DEVICE_ENABLED ) { +dev_dbg (priv->dev,"[%u] %s: TZ update trigger (%d mC)\n" , + hw_id, __func__, temp); +thermal_zone_device_update (s->tzd,THERMAL_EVENT_UNSPECIFIED ); + }else { +dev_dbg (priv->dev,"[%u] %s: TZ update trigger (%d mC) skipped as zone disabled\n" , + hw_id, __func__, temp); + } }else { -dev_dbg (priv->dev,"[%u] %s: no violation: %d\n" , - hw_id, __func__, temp); +dev_dbg (priv->dev,"[%u] %s: no violation: %d\n" , hw_id, __func__, temp); }if (tsens_version (priv) <VER_0_1 ) {
Signature · 1 line
2.17.1
Quoted 50 lines · Benjamin Li
'echo disabled > .../thermal_zoneX/mode' will disable the thermal core's polling mechanism to check for threshold trips. However, tsens supports an interrupt mechanism to receive notification of trips, implemented in commit
634e11d5b450("drivers: thermal: tsens: Add interrupt support"). This is used sometimes to run performance test cases.Currently the thermal zone mode that's set by userspace is not checked before propagating threshold trip events from IRQs. Let's fix this to restore the abilty to disable thermal throttling at runtime.
====================
Tested on MSM8939 running 5.16.0. This platform has 8 cores; the first four thermal zones control cpu0-3 and the last zone is for the other four CPUs together.
for f in
/sys/class/thermal/thermal_zone*; do
echo "disabled" > $f/mode
echo $f | paste - $f/type $f/mode
done
/sys/class/thermal/thermal_zone0cpu0-thermal disabled/sys/class/thermal/thermal_zone1cpu1-thermal disabled/sys/class/thermal/thermal_zone2cpu2-thermal disabled/sys/class/thermal/thermal_zone3cpu3-thermal disabled/sys/class/thermal/thermal_zone4cpu4567-thermal disabledWith mitigation thresholds at 75 degC and load running, we can now cruise past temp=75000 without CPU throttling kicking in.
watch -n 1 "grep ''
/sys/class/thermal/*/temp
/sys/class/thermal/*/cur_state/sys/bus/cpu/devices/cpu*/cpufreq/cpuinfo_cur_freq"
/sys/class/thermal/thermal_zone0/temp:82000/sys/class/thermal/thermal_zone1/temp:84000/sys/class/thermal/thermal_zone2/temp:87000/sys/class/thermal/thermal_zone3/temp:84000/sys/class/thermal/thermal_zone4/temp:84000/sys/class/thermal/cooling_device0/cur_state:0/sys/class/thermal/cooling_device1/cur_state:0/sys/bus/cpu/devices/cpu0/cpufreq/cpuinfo_cur_freq:1113600/sys/bus/cpu/devices/cpu1/cpufreq/cpuinfo_cur_freq:1113600/sys/bus/cpu/devices/cpu2/cpufreq/cpuinfo_cur_freq:1113600/sys/bus/cpu/devices/cpu3/cpufreq/cpuinfo_cur_freq:1113600/sys/bus/cpu/devices/cpu4/cpufreq/cpuinfo_cur_freq:800000/sys/bus/cpu/devices/cpu5/cpufreq/cpuinfo_cur_freq:800000/sys/bus/cpu/devices/cpu6/cpufreq/cpuinfo_cur_freq:800000/sys/bus/cpu/devices/cpu7/cpufreq/cpuinfo_cur_freq:800000
Quoted 2 lines
Reported-by Zac Crosby <[email protected]>Signed-off-by Benjamin Li <[email protected]>
Regards,
Bjorn
Quoted 34 lines
--- drivers/thermal/qcom/tsens.c | 15 +++++++++------ 1 file changed, 9 insertions(+), 6 deletions(-)drivers/thermal/qcom/tsens.c +9
-6@@ -509,13 +509,16 @@ static irqreturn_t tsens_irq_thread(int irq, void *data)spin_unlock_irqrestore (&priv->ul_lock, flags);if (trigger) { -dev_dbg (priv->dev,"[%u] %s: TZ update trigger (%d mC)\n" , - hw_id, __func__, temp); -thermal_zone_device_update (s->tzd, -THERMAL_EVENT_UNSPECIFIED ); +if (s->tzd->mode ==THERMAL_DEVICE_ENABLED ) { +dev_dbg (priv->dev,"[%u] %s: TZ update trigger (%d mC)\n" , + hw_id, __func__, temp); +thermal_zone_device_update (s->tzd,THERMAL_EVENT_UNSPECIFIED ); + }else { +dev_dbg (priv->dev,"[%u] %s: TZ update trigger (%d mC) skipped as zone disabled\n" , + hw_id, __func__, temp); + } }else { -dev_dbg (priv->dev,"[%u] %s: no violation: %d\n" , - hw_id, __func__, temp); +dev_dbg (priv->dev,"[%u] %s: no violation: %d\n" , hw_id, __func__, temp); }if (tsens_version (priv) <VER_0_1 ) {Signature · 1 line
2.17.1