cmd: bcb: fix bcb struct alignment issue

PATCH In review Gary Bisson 3 participants 3 messages Jan 11, 2022 – Feb 5, 2022

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 cmd: bcb: fix bcb struct alignment issue

Without this patch the bcb struct could be located at an odd address which resulted in data not being copied to the buffer.

Here was the repro steps (from Mattijs):
=> mmc dev 1
=> bcb load 1 misc
=> bcb dump command
00000000: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00000010: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 => part start mmc 1 misc misc_start
=> mmc read ${loadaddr} ${misc_start} 4
=> bcb load 1 misc
=> bcb dump command
00000000: 62 6f 6f 74 6f 6e 63 65 2d 62 6f 6f 74 6c 6f 61 00000010: 64 65 72 00 00 00 00 00 00 00 00 00 00 00 00 00

This behavior was observed on an Amlogic A311D (ARM64) platform with a recent GCC toolchain (11.2.0) but is most likely affecting other platforms.

To avoid issues the structure is aligned on DMA minimum alignment value as it is passed directly to the read function.

---
 cmd/bcb.c | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)
cmd/bcb.c +2 -1
index 6b6f1e9a2f1..92f4d27990d 100644
@@ -12,6 +12,7 @@
 #include <log.h>
 #include <part.h>
 #include <malloc.h>
+#include <memalign.h>
 
 enum bcb_cmd {
 	BCB_CMD_LOAD,
@@ -24,7 +25,7 @@ enum bcb_cmd {
 
 static int bcb_dev = -1;
 static int bcb_part = -1;
-static struct bootloader_message bcb = { { 0 } };
+static struct bootloader_message bcb __aligned(ARCH_DMA_MINALIGN) = { { 0 } };
 
 static int bcb_cmd_get(char *cmd)
 {
Signature · 1 line
2.34.1
Tested-by on v1 1/1
#1 lore raw

Hi Gary,

Thank you for your patch.

Quoted 20 lines · Gary Bisson

Without this patch the bcb struct could be located at an odd address which resulted in data not being copied to the buffer.

Here was the repro steps (from Mattijs):
=> mmc dev 1
=> bcb load 1 misc
=> bcb dump command
00000000: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00000010: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 => part start mmc 1 misc misc_start
=> mmc read ${loadaddr} ${misc_start} 4
=> bcb load 1 misc
=> bcb dump command
00000000: 62 6f 6f 74 6f 6e 63 65 2d 62 6f 6f 74 6c 6f 61 00000010: 64 65 72 00 00 00 00 00 00 00 00 00 00 00 00 00

This behavior was observed on an Amlogic A311D (ARM64) platform with a recent GCC toolchain (11.2.0) but is most likely affecting other platforms.

Quoted 7 lines

To avoid issues the structure is aligned on DMA minimum alignment value as it is passed directly to the read function.

---
 cmd/bcb.c | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)
Quoted 24 lines
cmd/bcb.c +2 -1
index 6b6f1e9a2f1..92f4d27990d 100644
@@ -12,6 +12,7 @@
 #include <log.h>
 #include <part.h>
 #include <malloc.h>
+#include <memalign.h>
 
 enum bcb_cmd {
 	BCB_CMD_LOAD,
@@ -24,7 +25,7 @@ enum bcb_cmd {
 
 static int bcb_dev = -1;
 static int bcb_part = -1;
-static struct bootloader_message bcb = { { 0 } };
+static struct bootloader_message bcb __aligned(ARCH_DMA_MINALIGN) = { { 0 } };
 
 static int bcb_cmd_get(char *cmd)
 {
Signature · 1 line
2.34.1
#2 lore raw

PATCH 1/1 cmd: bcb: fix bcb struct alignment issue

In reply to Gary Bisson
Quoted 19 lines

Without this patch the bcb struct could be located at an odd address which resulted in data not being copied to the buffer.
Here was the repro steps (from Mattijs):
=> mmc dev 1
=> bcb load 1 misc
=> bcb dump command
00000000: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00000010: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
=> part start mmc 1 misc misc_start
=> mmc read ${loadaddr} ${misc_start} 4
=> bcb load 1 misc
=> bcb dump command
00000000: 62 6f 6f 74 6f 6e 63 65 2d 62 6f 6f 74 6c 6f 61 00000010: 64 65 72 00 00 00 00 00 00 00 00 00 00 00 00 00 This behavior was observed on an Amlogic A311D (ARM64) platform with a recent GCC toolchain (11.2.0) but is most likely affecting other platforms.
To avoid issues the structure is aligned on DMA minimum alignment value as it is passed directly to the read function.

Quoted 2 lines

Applied to u-boot-imx, master, thanks !

Best regards,
Stefano Babic