Allow lower values for the flush parameter
Samuel Thibault
maintainerPATCH 1/1 Allow lower values for the flush parameter
Users needing it with the dectlk synth report that a 100ms flush delay is still noticeable and prefer to set it to e.g. 10ms. This leaves the default to 4000ms (since hitting it is a sign that the cable is faulty and should be replaced), but allows to set it as short as 10ms.
Signed-off-by Samuel Thibault <[email protected]>
drivers/accessibility/speakup/synth.c +1 -1
@@ -348,7 +348,7 @@ struct var_t synth_time_vars[] = { { TRIGGER, .u.n = {NULL, 20, 10, 2000, 0, 0, NULL } }, { JIFFY, .u.n = {NULL, 50, 20, 200, 0, 0, NULL } }, { FULL, .u.n = {NULL, 400, 200, 60000, 0, 0, NULL } }, - { FLUSH, .u.n = {NULL, 4000, 100, 4000, 0, 0, NULL } }, + { FLUSH, .u.n = {NULL, 4000, 10, 4000, 0, 0, NULL } },V_LAST_VAR };