thermal: devfreq_cooling: use local ops instead of global ops
PATCH 1/1 thermal: devfreq_cooling: use local ops instead of global ops
Fix access illegal address problem in following condition:
There are muti devfreq cooling devices in system, some of them has em model but other does not, energy model ops such as state2power will append to global devfreq_cooling_ops when the cooling device with em model register. It makes the cooling device without em model also use devfreq_cooling_ops after appending when register later by of_devfreq_cooling_register_power() or of_devfreq_cooling_register().
IPA governor regards the cooling devices without em model as a power actor because they also have energy model ops, and will access illegal address at dfc->em_pd when execute cdev->ops->get_requested_power, cdev->ops->state2power or cdev->ops->power2state.
--- drivers/thermal/devfreq_cooling.c | 25 ++++++++++++++++++------- 1 file changed, 18 insertions(+), 7 deletions(-)
drivers/thermal/devfreq_cooling.c +18 -7
@@ -358,21 +358,28 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df,struct thermal_cooling_device *cdev;struct device *dev = df->dev.parent;struct devfreq_cooling_device *dfc; +struct thermal_cooling_device_ops *ops;char *name;int err, num_opps; - dfc =kzalloc (sizeof (*dfc),GFP_KERNEL ); -if (!dfc) + ops =kmemdup (&devfreq_cooling_ops,sizeof (*ops),GFP_KERNEL ); +if (!ops)return ERR_PTR (-ENOMEM ); + dfc =kzalloc (sizeof (*dfc),GFP_KERNEL ); +if (!dfc) { + err = -ENOMEM ; + goto free_ops; + } + dfc->devfreq = df; dfc->em_pd =em_pd_get (dev);if (dfc->em_pd) { - devfreq_cooling_ops.get_requested_power = + ops->get_requested_power = devfreq_cooling_get_requested_power; - devfreq_cooling_ops.state2power = devfreq_cooling_state2power; - devfreq_cooling_ops.power2state = devfreq_cooling_power2state; + ops->state2power = devfreq_cooling_state2power; + ops->power2state = devfreq_cooling_power2state; dfc->power_ops = dfc_power;
@@ -407,8 +414,7 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df,if (!name) goto remove_qos_req; - cdev =thermal_of_cooling_device_register (np, name, dfc, - &devfreq_cooling_ops); + cdev =thermal_of_cooling_device_register (np, name, dfc, ops);kfree (name);if (IS_ERR (cdev)) {
@@ -429,6 +435,8 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df,kfree (dfc->freq_table); free_dfc:kfree (dfc); +free_ops: +kfree (ops);return ERR_PTR (err); }
@@ -510,11 +518,13 @@ EXPORT_SYMBOL_GPL(devfreq_cooling_em_register);void devfreq_cooling_unregister (struct thermal_cooling_device *cdev) {struct devfreq_cooling_device *dfc; +const struct thermal_cooling_device_ops *ops;struct device *dev;if (IS_ERR_OR_NULL (cdev))return ; + ops = cdev->ops; dfc = cdev->devdata; dev = dfc->devfreq->dev.parent;
@@ -525,5 +535,6 @@ void devfreq_cooling_unregister(struct thermal_cooling_device *cdev)kfree (dfc->freq_table);kfree (dfc); +kfree (ops); }EXPORT_SYMBOL_GPL (devfreq_cooling_unregister);
Signature · 1 line
2.29.0
Lukasz Luba
reviewerHi Kant,
Quoted 8 lines · Kant Fan
Fix access illegal address problem in following condition:
There are muti devfreq cooling devices in system, some of them has em model but other does not, energy model ops such as state2power will append to globaldevfreq_cooling_opswhen the cooling device with em model register. It makes the cooling device without em model also usedevfreq_cooling_opsafter appending when register later byof_devfreq_cooling_register_power()orof_devfreq_cooling_register().
Quoted 6 lines
IPA governor regards the cooling devices without em model as a power actor because they also have energy model ops, and will access illegal address at
dfc->em_pdwhen executecdev->ops->get_requested_power,cdev->ops->state2powerorcdev->ops->power2state.Signed-off-by Kant Fan <[email protected]>
Thank you for finding this issue. This was also an issue since the beginning of that code. The modified global ops after first registration which went through, was also previously there. Thus, we would need two different patches for stable kernels.
For this one, please add the tag:
This patch would also go via stable tree for kernels v5.11+ Please read the process how to send a patch which will be merged to the stable tree.
There will be a need to create another patch(es) for stable kernels with
In those kernels also the global ops is modified and might not support properly many cooling devices. It's present in other stable kernels:
v5.10 and older
Quoted 76 lines
--- drivers/thermal/devfreq_cooling.c | 25 ++++++++++++++++++------- 1 file changed, 18 insertions(+), 7 deletions(-)drivers/thermal/devfreq_cooling.c +17
-7@@ -358,21 +358,28 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df,struct thermal_cooling_device *cdev;struct device *dev = df->dev.parent;struct devfreq_cooling_device *dfc; +struct thermal_cooling_device_ops *ops;char *name;int err, num_opps; - dfc =kzalloc (sizeof (*dfc),GFP_KERNEL ); -if (!dfc) + ops =kmemdup (&devfreq_cooling_ops,sizeof (*ops),GFP_KERNEL ); +if (!ops)return ERR_PTR (-ENOMEM ); + dfc =kzalloc (sizeof (*dfc),GFP_KERNEL ); +if (!dfc) { + err = -ENOMEM ; + goto free_ops; + } + dfc->devfreq = df; dfc->em_pd =em_pd_get (dev);if (dfc->em_pd) { - devfreq_cooling_ops.get_requested_power = + ops->get_requested_power = devfreq_cooling_get_requested_power; - devfreq_cooling_ops.state2power = devfreq_cooling_state2power; - devfreq_cooling_ops.power2state = devfreq_cooling_power2state; + ops->state2power = devfreq_cooling_state2power; + ops->power2state = devfreq_cooling_power2state; dfc->power_ops = dfc_power;@@ -407,8 +414,7 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df,if (!name) goto remove_qos_req; - cdev =thermal_of_cooling_device_register (np, name, dfc, - &devfreq_cooling_ops); + cdev =thermal_of_cooling_device_register (np, name, dfc, ops);kfree (name);if (IS_ERR (cdev)) {@@ -429,6 +435,8 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df,kfree (dfc->freq_table); free_dfc:kfree (dfc); +free_ops: +kfree (ops);return ERR_PTR (err); }@@ -510,11 +518,13 @@ EXPORT_SYMBOL_GPL(devfreq_cooling_em_register);void devfreq_cooling_unregister (struct thermal_cooling_device *cdev) {struct devfreq_cooling_device *dfc; +const struct thermal_cooling_device_ops *ops;struct device *dev;if (IS_ERR_OR_NULL (cdev))return ; + ops = cdev->ops; dfc = cdev->devdata; dev = dfc->devfreq->dev.parent;
drivers/thermal/devfreq_cooling.c void devfreq_cooling_unregister(struct thermal_cooling_device *cdev) · line 540
Quoted 6 lines
drivers/thermal/devfreq_cooling.c +1
-0@@ -525,5 +535,6 @@ void devfreq_cooling_unregister(struct thermal_cooling_device *cdev)kfree (dfc->freq_table);kfree (dfc); +kfree (ops); }EXPORT_SYMBOL_GPL (devfreq_cooling_unregister);
The fix looks good.
Quoted 104 lines · Lukasz Luba
Hi Kant,
Quoted 8 lines · Kant Fan
Fix access illegal address problem in following condition:
There are muti devfreq cooling devices in system, some of them has em model but other does not, energy model ops such as state2power will append to globaldevfreq_cooling_opswhen the cooling device with em model register. It makes the cooling device without em model also usedevfreq_cooling_opsafter appending when register later byof_devfreq_cooling_register_power()orof_devfreq_cooling_register().Quoted 6 lines
IPA governor regards the cooling devices without em model as a power actor because they also have energy model ops, and will access illegal address at
dfc->em_pdwhen executecdev->ops->get_requested_power,cdev->ops->state2powerorcdev->ops->power2state.Signed-off-by Kant Fan <[email protected]>Thank you for finding this issue. This was also an issue since the beginning of that code. The modified global ops after first registration which went through, was also previously there. Thus, we would need two different patches for stable kernels.
For this one, please add the tag:
Fixes 615510fe13bd2 ("thermal: devfreq_cooling: remove old power model and use EM")This patch would also go via stable tree for kernels v5.11+ Please read the process how to send a patch which will be merged to the stable tree.
There will be a need to create another patch(es) for stable kernels with
Fixes a76caf55e5b35 ("thermal: Add devfreq cooling")In those kernels also the global ops is modified and might not support properly many cooling devices. It's present in other stable kernels:
v5.10 and olderQuoted 68 lines
---
drivers/thermal/devfreq_cooling.c| 25 ++++++++++++++++++-------1 file changed, 18 insertions(+), 7 deletions(-)drivers/thermal/devfreq_cooling.c +13
-7@@ -358,21 +358,28 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df, struct thermal_cooling_device *cdev; struct device *dev = df->dev.parent; struct devfreq_cooling_device *dfc; + struct thermal_cooling_device_ops *ops; char *name; int err, num_opps; - dfc = kzalloc(sizeof(*dfc), GFP_KERNEL); - if (!dfc) + ops = kmemdup(&devfreq_cooling_ops, sizeof(*ops), GFP_KERNEL); + if (!ops) return ERR_PTR(-ENOMEM); + dfc = kzalloc(sizeof(*dfc), GFP_KERNEL); + if (!dfc) { + err = -ENOMEM; + goto free_ops; + } + dfc->devfreq = df; dfc->em_pd = em_pd_get(dev); if (dfc->em_pd) { - devfreq_cooling_ops.get_requested_power = + ops->get_requested_power = devfreq_cooling_get_requested_power; - devfreq_cooling_ops.state2power = devfreq_cooling_state2power; - devfreq_cooling_ops.power2state = devfreq_cooling_power2state; + ops->state2power = devfreq_cooling_state2power; + ops->power2state = devfreq_cooling_power2state; dfc->power_ops = dfc_power;@@ -407,8 +414,7 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df, if (!name) goto remove_qos_req; - cdev = thermal_of_cooling_device_register(np, name, dfc, - &devfreq_cooling_ops); + cdev = thermal_of_cooling_device_register(np, name, dfc, ops); kfree(name); if (IS_ERR(cdev)) {@@ -429,6 +435,8 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df, kfree(dfc->freq_table);
free_dfc:
kfree(dfc);
+free_ops:
+ kfree(ops);
returnERR_PTR(err);
}drivers/thermal/devfreq_cooling.c +2
-0@@ -510,11 +518,13 @@ EXPORT_SYMBOL_GPL(devfreq_cooling_em_register); void devfreq_cooling_unregister(struct thermal_cooling_device *cdev) { struct devfreq_cooling_device *dfc; + const struct thermal_cooling_device_ops *ops; struct device *dev; if (IS_ERR_OR_NULL(cdev)) return; + ops = cdev->ops; dfc = cdev->devdata; dev = dfc->devfreq->dev.parent;@@ -525,5 +535,6 @@ void devfreq_cooling_unregister(struct
Quoted 8 lines
drivers/thermal/devfreq_cooling.c void devfreq_cooling_unregister(struct thermal_cooling_device *cdev) · line 540
Quoted 6 lines
drivers/thermal/devfreq_cooling.c +1
-0thermal_cooling_device *cdev) kfree(dfc->freq_table); kfree(dfc); + kfree(ops); } EXPORT_SYMBOL_GPL(devfreq_cooling_unregister);The fix looks good.
Hi Lukasz,
Thanks for your advice. According to that, I made two separate patches for mainline and the stable trees:
The first patch (patchwork.kernel.org: Message ID: [email protected]) is for mainline. I added the 'fix' tag and 'Cc: [email protected] # 5.13+' to remind which stable trees should be back-ported.
The second patch (patchwork.kernel.org: Message ID: [email protected]) is for stable tree v5.10 and older. I added an upstream commit ID to indicate where the patch comes from. I also added 'Cc: [email protected] # 4.4+' to remind which stable trees should be back-ported. Please check if they are correct. Thank you.
Kant Fan
Lukasz Luba
reviewerQuoted 114 lines · Kant Fan
Quoted 104 lines · Lukasz Luba
Hi Kant,
Quoted 8 lines · Kant Fan
Fix access illegal address problem in following condition:
There are muti devfreq cooling devices in system, some of them has em model but other does not, energy model ops such as state2power will append to globaldevfreq_cooling_opswhen the cooling device with em model register. It makes the cooling device without em model also usedevfreq_cooling_opsafter appending when register later byof_devfreq_cooling_register_power()orof_devfreq_cooling_register().Quoted 6 lines
IPA governor regards the cooling devices without em model as a power actor because they also have energy model ops, and will access illegal address at
dfc->em_pdwhen executecdev->ops->get_requested_power,cdev->ops->state2powerorcdev->ops->power2state.Signed-off-by Kant Fan <[email protected]>Thank you for finding this issue. This was also an issue since the beginning of that code. The modified global ops after first registration which went through, was also previously there. Thus, we would need two different patches for stable kernels.
For this one, please add the tag:
Fixes 615510fe13bd2 ("thermal: devfreq_cooling: remove old power model and use EM")This patch would also go via stable tree for kernels v5.11+ Please read the process how to send a patch which will be merged to the stable tree.
There will be a need to create another patch(es) for stable kernels with
Fixes a76caf55e5b35 ("thermal: Add devfreq cooling")In those kernels also the global ops is modified and might not support properly many cooling devices. It's present in other stable kernels:
v5.10 and olderQuoted 68 lines
---
drivers/thermal/devfreq_cooling.c| 25 ++++++++++++++++++-------1 file changed, 18 insertions(+), 7 deletions(-)drivers/thermal/devfreq_cooling.c +13
-7@@ -358,21 +358,28 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df, struct thermal_cooling_device *cdev; struct device *dev = df->dev.parent; struct devfreq_cooling_device *dfc; + struct thermal_cooling_device_ops *ops; char *name; int err, num_opps; - dfc = kzalloc(sizeof(*dfc), GFP_KERNEL); - if (!dfc) + ops = kmemdup(&devfreq_cooling_ops, sizeof(*ops), GFP_KERNEL); + if (!ops) return ERR_PTR(-ENOMEM); + dfc = kzalloc(sizeof(*dfc), GFP_KERNEL); + if (!dfc) { + err = -ENOMEM; + goto free_ops; + } + dfc->devfreq = df; dfc->em_pd = em_pd_get(dev); if (dfc->em_pd) { - devfreq_cooling_ops.get_requested_power = + ops->get_requested_power = devfreq_cooling_get_requested_power; - devfreq_cooling_ops.state2power = devfreq_cooling_state2power; - devfreq_cooling_ops.power2state = devfreq_cooling_power2state; + ops->state2power = devfreq_cooling_state2power; + ops->power2state = devfreq_cooling_power2state; dfc->power_ops = dfc_power;@@ -407,8 +414,7 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df, if (!name) goto remove_qos_req; - cdev = thermal_of_cooling_device_register(np, name, dfc, - &devfreq_cooling_ops); + cdev = thermal_of_cooling_device_register(np, name, dfc, ops); kfree(name); if (IS_ERR(cdev)) {@@ -429,6 +435,8 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df, kfree(dfc->freq_table);
free_dfc:
kfree(dfc);
+free_ops:
+ kfree(ops);
returnERR_PTR(err);
}drivers/thermal/devfreq_cooling.c +2
-0@@ -510,11 +518,13 @@ EXPORT_SYMBOL_GPL(devfreq_cooling_em_register); void devfreq_cooling_unregister(struct thermal_cooling_device *cdev) { struct devfreq_cooling_device *dfc; + const struct thermal_cooling_device_ops *ops; struct device *dev; if (IS_ERR_OR_NULL(cdev)) return; + ops = cdev->ops; dfc = cdev->devdata; dev = dfc->devfreq->dev.parent;@@ -525,5 +535,6 @@ void devfreq_cooling_unregister(structQuoted 8 lines
drivers/thermal/devfreq_cooling.c void devfreq_cooling_unregister(struct thermal_cooling_device *cdev) · line 540
Quoted 6 lines
drivers/thermal/devfreq_cooling.c +1
-0thermal_cooling_device *cdev) kfree(dfc->freq_table); kfree(dfc); + kfree(ops); } EXPORT_SYMBOL_GPL(devfreq_cooling_unregister);The fix looks good.
Quoted 5 lines
Hi Lukasz,
Thanks for your advice. According to that, I made two separate patches for mainline and the stable trees:
The first patch (patchwork.kernel.org: Message ID: [email protected]) is for mainline. I added the 'fix' tag and 'Cc: [email protected] # 5.13+' to remind which stable trees should be back-ported.
The second patch (patchwork.kernel.org: Message ID: [email protected]) is for stable tree v5.10 and older. I added an upstream commit ID to indicate where the patch comes from. I also added 'Cc: [email protected] # 4.4+' to remind which stable trees should be back-ported. Please check if they are correct. Thank you.
Thank you for sending them. Let me have a look.