Skip to contentSkip to conversation

dt-bindings: mailbox: qcom: set correct #clock-cells

PATCH Applied Robert Marko 2 participants 5 messages Aug 18, 2022 – Oct 18, 2022

Subsystems (4)
lore
Share & tools
lore
#0 lore raw

PATCH v9 1/4 dt-bindings: mailbox: qcom: set correct #clock-cells

IPQ6018 and IPQ8074 require #clock-cells to be set to 1 as their APSS clock driver provides multiple clock outputs.

So allow setting 1 as #clock-cells and check that its set to 1 for IPQ6018 and IPQ8074, check others for 0 as its currently.

---
Changes in v3:
* Drop not needed blank line

Changes in v2:
* Correct subject name

---
 .../bindings/mailbox/qcom,apcs-kpss-global.yaml | 17 ++++++++++++++++-
 1 file changed, 16 insertions(+), 1 deletion(-)
Documentation/devicetree/bindings/mailbox/qcom,apcs-kpss-global.yaml +16 -1
index f504652fc0ea..982bcdebba4c 100644
@@ -54,7 +54,7 @@ properties:
     const: 1
 
   '#clock-cells':
-    const: 0
+    enum: [0, 1]
 
   clock-names:
     minItems: 2
@@ -100,6 +100,21 @@ allOf:
       properties:
         clocks:
           maxItems: 3
+  - if:
+      properties:
+        compatible:
+          enum:
+            - qcom,ipq6018-apcs-apps-global
+            - qcom,ipq8074-apcs-apps-global
+    then:
+      properties:
+        '#clock-cells':
+          const: 1
+    else:
+      properties:
+        '#clock-cells':
+          const: 0
+
 examples:
 
   # Example apcs with msm8996
Signature · 1 line
2.37.2
#1 lore raw

PATCH v9 2/4 dt-bindings: mailbox: qcom: correct clocks for IPQ6018 and IPQ8074

IPQ6018 APSS driver is registered by APCS as they share the same register space, and it uses "pll" and "xo" as inputs.

Correct the allowed clocks for IPQ6018 and IPQ8074 as they share the same driver to allow "pll" and "xo" as clock-names.

---
Changes in v8:
* Add maxItems to clocks and clock-names

---
 .../mailbox/qcom,apcs-kpss-global.yaml        | 46 ++++++++++++++-----
 1 file changed, 34 insertions(+), 12 deletions(-)
Documentation/devicetree/bindings/mailbox/qcom,apcs-kpss-global.yaml +34 -12
index 982bcdebba4c..f24fd84b4b05 100644
@@ -45,10 +45,7 @@ properties:
   clocks:
     description: phandles to the parent clocks of the clock driver
     minItems: 2
-    items:
-      - description: primary pll parent of the clock driver
-      - description: auxiliary parent
-      - description: reference clock
+    maxItems: 3
 
   '#mbox-cells':
     const: 1
@@ -58,10 +55,7 @@ properties:
 
   clock-names:
     minItems: 2
-    items:
-      - const: pll
-      - const: aux
-      - const: ref
+    maxItems: 3
 
 required:
   - compatible
@@ -75,8 +69,6 @@ allOf:
       properties:
         compatible:
           enum:
-            - qcom,ipq6018-apcs-apps-global
-            - qcom,ipq8074-apcs-apps-global
             - qcom,msm8916-apcs-kpss-global
             - qcom,msm8994-apcs-kpss-global
             - qcom,msm8996-apcs-hmss-global
@@ -90,7 +82,13 @@ allOf:
     then:
       properties:
         clocks:
-          maxItems: 2
+          items:
+            - description: primary pll parent of the clock driver
+            - description: auxiliary parent
+        clock-names:
+          items:
+            - const: pll
+            - const: aux
   - if:
       properties:
         compatible:
@@ -99,7 +97,31 @@ allOf:
     then:
       properties:
         clocks:
-          maxItems: 3
+          items:
+            - description: primary pll parent of the clock driver
+            - description: auxiliary parent
+            - description: reference clock
+        clock-names:
+          items:
+            - const: pll
+            - const: aux
+            - const: ref
+  - if:
+      properties:
+        compatible:
+          enum:
+            - qcom,ipq6018-apcs-apps-global
+            - qcom,ipq8074-apcs-apps-global
+    then:
+      properties:
+        clocks:
+          items:
+            - description: primary pll parent of the clock driver
+            - description: XO clock
+        clock-names:
+          items:
+            - const: pll
+            - const: xo
   - if:
       properties:
         compatible:
Signature · 1 line
2.37.2
#2 lore raw

PATCH v9 3/4 mailbox: qcom-apcs-ipc: add IPQ8074 APSS clock support

In reply to Robert Marko

IPQ8074 has the APSS clock controller utilizing the same register space as the APCS, so provide access to the APSS utilizing a child device like IPQ6018.

IPQ6018 and IPQ8074 use the same controller and driver, so just utilize IPQ6018 match data for IPQ8074.

---
Changes in v7:
* Dont max_register modifications
* Drop custom IPQ8074 match data and use IPQ6018 one as they share the controller and driver

Changes in v5:
* Use lower case hex for max_register
* Update the APSS clock name to match the new one without commas

---
 drivers/mailbox/qcom-apcs-ipc-mailbox.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/mailbox/qcom-apcs-ipc-mailbox.c +1 -1
index 80a54d81412e..f1f0e87a79e6 100644
@@ -142,7 +142,7 @@ static int qcom_apcs_ipc_remove(struct platform_device *pdev)
 /* .data is the offset of the ipc register within the global block */
 static const struct of_device_id qcom_apcs_ipc_of_match[] = {
 	{ .compatible = "qcom,ipq6018-apcs-apps-global", .data = &ipq6018_apcs_data },
-	{ .compatible = "qcom,ipq8074-apcs-apps-global", .data = &msm8994_apcs_data },
+	{ .compatible = "qcom,ipq8074-apcs-apps-global", .data = &ipq6018_apcs_data },
 	{ .compatible = "qcom,msm8916-apcs-kpss-global", .data = &msm8916_apcs_data },
 	{ .compatible = "qcom,msm8939-apcs-kpss-global", .data = &msm8916_apcs_data },
 	{ .compatible = "qcom,msm8953-apcs-kpss-global", .data = &msm8994_apcs_data },
Signature · 1 line
2.37.2
#3 lore raw

PATCH v9 4/4 arm64: dts: qcom: ipq8074: add clocks to APCS

In reply to Robert Marko

APCS now has support for providing the APSS clocks as the child device for IPQ8074.

So, add the A53 PLL and XO clocks in order to use APCS as the CPU clocksource for APSS scaling.

---
 arch/arm64/boot/dts/qcom/ipq8074.dtsi | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)
arch/arm64/boot/dts/qcom/ipq8074.dtsi +2 -1
index bace14b742a1..7d4ff7d8a239 100644
@@ -704,8 +704,9 @@ watchdog: watchdog@b017000 {
 		apcs_glb: mailbox@b111000 {
 			compatible = "qcom,ipq8074-apcs-apps-global";
 			reg = <0x0b111000 0x1000>;
-
 			#clock-cells = <1>;
+			clocks = <&a53pll>, <&xo>;
+			clock-names = "pll", "xo";
 			#mbox-cells = <1>;
 		};
 
Signature · 1 line
2.37.2
maintainer Applied
#4 lore raw

Re: (subset) [PATCH v9 1/4] dt-bindings: mailbox: qcom: set correct #clock-cells

In reply to Robert Marko
Quoted 8 lines · Robert Marko

IPQ6018 and IPQ8074 require #clock-cells to be set to 1 as their APSS clock driver provides multiple clock outputs.

So allow setting 1 as #clock-cells and check that its set to 1 for IPQ6018 and IPQ8074, check others for 0 as its currently.

[...]

Applied, thanks!

[4/4] arm64: dts: qcom: ipq8074: add clocks to APCS

      commit: fd8bdb451c6541b40e5977defcfebfe51713a538

Best regards,

Signature · 1 line
Bjorn Andersson <[email protected]>