hwmon: (aquacomputer_d5next) Add support for Aquacomputer High Flow Next
Aleksa Savic
maintainerPATCH v2 1/1 hwmon: (aquacomputer_d5next) Add support for Aquacomputer High Flow Next
Extend aquacomputer_d5next driver to expose various hardware sensors of the Aquacomputer High Flow Next flow sensor, which communicates through a proprietary USB HID protocol.
The High Flow Next exposes +5V voltages, water quality, conductivity and flow readings. A temperature sensor can be connected to it, in which case it provides its reading and an estimation of the dissipated/absorbed power in the liquid cooling loop.
Additionally, serial number and firmware version are exposed through debugfs.
Registry offsets were discovered and tested by users on Github [1] [2].
[1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/issues/8
[2] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/34
---
Changes in v2:
- Rebased code and docs properly
--- Documentation/hwmon/aquacomputer_d5next.rst | 5 ++ drivers/hwmon/Kconfig | 6 +- drivers/hwmon/aquacomputer_d5next.c | 91 ++++++++++++++++++++- 3 files changed, 96 insertions(+), 6 deletions(-)
Documentation/hwmon/aquacomputer_d5next.rst +5 -0
@@ -10,6 +10,7 @@ Supported devices: * Aquacomputer Farbwerk 360 RGB controller * Aquacomputer Octo fan controller * Aquacomputer Quadro fan controller +* Aquacomputer High Flow Next sensor Author: Aleksa Savic
@@ -43,6 +44,10 @@ voltage and current. The Farbwerk and Farbwerk 360 expose four temperature sensors. Additionally, sixteen virtual temperature sensors of the Farbwerk 360 are exposed. +The High Flow Next exposes +5V voltages, water quality, conductivity and flow readings. +A temperature sensor can be connected to it, in which case it provides its reading +and an estimation of the dissipated/absorbed power in the liquid cooling loop. + Depending on the device, not all sysfs and debugfs entries will be available. Writing to virtual temperature sensors is not currently supported.
drivers/hwmon/Kconfig +3 -3
@@ -257,14 +257,14 @@ config SENSORS_AHT10 will be called aht10. config SENSORS_AQUACOMPUTER_D5NEXT - tristate "Aquacomputer D5 Next, Octo, Quadro, Farbwerk, and Farbwerk 360" + tristate "Aquacomputer D5 Next, Octo, Quadro, Farbwerk, Farbwerk 360, High Flow Next" depends on USB_HID select CRC16 help If you say yes here you get support for sensors and fans of the Aquacomputer D5 Next watercooling pump, Octo and Quadro fan - controllers, Farbwerk and Farbwerk 360 RGB controllers, where - available. + controllers, Farbwerk and Farbwerk 360 RGB controllers, High Flow + Next sensor, where available. This driver can also be built as a module. If so, the module will be called aquacomputer_d5next.
drivers/hwmon/aquacomputer_d5next.c +88 -3
158 lines not on this page · raw message
Signature · 1 line
2.37.3
Quoted 12 lines · Aleksa Savic
Extend
aquacomputer_d5nextdriver to expose various hardware sensors of the Aquacomputer High Flow Next flow sensor, which communicates through a proprietary USB HID protocol.The High Flow Next exposes +5V voltages, water quality, conductivity and flow readings. A temperature sensor can be connected to it, in which case it provides its reading and an estimation of the dissipated/absorbed power in the liquid cooling loop.
Additionally, serial number and firmware version are exposed through debugfs.
Quoted 6 lines
Registry offsets were discovered and tested by users on Github [1] [2].
[1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/issues/8
[2] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/34Signed-off-by Aleksa Savic <[email protected]>
Applied to hwmon-next.
Thanks,
Guenter
Quoted 226 lines
---
Changes in v2:
- Rebased code and docs properly--- Documentation/hwmon/aquacomputer_d5next.rst | 5 ++ drivers/hwmon/Kconfig | 6 +- drivers/hwmon/aquacomputer_d5next.c | 91 ++++++++++++++++++++- 3 files changed, 96 insertions(+), 6 deletions(-)Documentation/hwmon/aquacomputer_d5next.rst +5
-0@@ -10,6 +10,7 @@ Supported devices: * Aquacomputer Farbwerk 360 RGB controller * Aquacomputer Octo fan controller * Aquacomputer Quadro fan controller +* Aquacomputer High Flow Next sensor Author: Aleksa Savic@@ -43,6 +44,10 @@ voltage and current. The Farbwerk and Farbwerk 360 expose four temperature sensors. Additionally, sixteen virtual temperature sensors of the Farbwerk 360 are exposed. +The High Flow Next exposes +5V voltages, water quality, conductivity and flow readings. +A temperature sensor can be connected to it, in which case it provides its reading +and an estimation of the dissipated/absorbed power in the liquid cooling loop. + Depending on the device, not all sysfs and debugfs entries will be available. Writing to virtual temperature sensors is not currently supported.drivers/hwmon/Kconfig +3
-3@@ -257,14 +257,14 @@ config SENSORS_AHT10 will be called aht10. config SENSORS_AQUACOMPUTER_D5NEXT - tristate "Aquacomputer D5 Next, Octo, Quadro, Farbwerk, and Farbwerk 360" + tristate "Aquacomputer D5 Next, Octo, Quadro, Farbwerk, Farbwerk 360, High Flow Next" depends on USB_HID select CRC16 help If you say yes here you get support for sensors and fans of the Aquacomputer D5 Next watercooling pump, Octo and Quadro fan - controllers, Farbwerk and Farbwerk 360 RGB controllers, where - available. + controllers, Farbwerk and Farbwerk 360 RGB controllers, High Flow + Next sensor, where available. This driver can also be built as a module. If so, the module will be called aquacomputer_d5next.drivers/hwmon/aquacomputer_d5next.c +88
-3@@ -1,7 +1,7 @@// SPDX-License-Identifier: GPL-2.0+ /* * hwmon driver for Aquacomputer devices (D5 Next, Farbwerk, Farbwerk 360, Octo, -* Quadro) +* Quadro, High Flow Next) * * Aquacomputer devices send HID reports (with ID 0x01) every second to report * sensor values. @@ -26,15 +26,17 @@#define USB_PRODUCT_ID_D5NEXT 0xf00e#define USB_PRODUCT_ID_FARBWERK360 0xf010#define USB_PRODUCT_ID_OCTO 0xf011 +#define USB_PRODUCT_ID_HIGHFLOWNEXT 0xf012 -enum kinds { d5next, farbwerk, farbwerk360, octo, quadro }; +enum kinds { d5next, farbwerk, farbwerk360, octo, quadro, highflownext };static const char *const aqc_device_names[] = { [d5next] ="d5next" , [farbwerk] ="farbwerk" , [farbwerk360] ="farbwerk360" , [octo] ="octo" , - [quadro] ="quadro" + [quadro] ="quadro" , + [highflownext] ="highflownext" };#define DRIVER_NAME "aquacomputer_d5next"@@ -120,6 +122,16 @@ static u8 quadro_sensor_fan_offsets[] = { 0x70, 0x7D, 0x8A, 0x97 };/* Fan speed registers in Quadro control report (from 0-100%) */ static u16 quadro_ctrl_fan_offsets[] = {0x36 ,0x8b ,0xe0 ,0x135 }; +/* Register offsets for the High Flow Next */ +#define HIGHFLOWNEXT_NUM_SENSORS 2 +#define HIGHFLOWNEXT_SENSOR_START 85 +#define HIGHFLOWNEXT_FLOW 81 +#define HIGHFLOWNEXT_WATER_QUALITY 89 +#define HIGHFLOWNEXT_POWER 91 +#define HIGHFLOWNEXT_CONDUCTIVITY 95 +#define HIGHFLOWNEXT_5V_VOLTAGE 97 +#define HIGHFLOWNEXT_5V_VOLTAGE_USB 99 +/* Labels for D5 Next */ static const char *const label_d5next_temp[] = {"Coolant temp" @@ -228,6 +240,27 @@ static const char *const label_quadro_speeds[] = {"Flow speed [dL/h]" }; +/* Labels for High Flow Next */ +static const char *const label_highflownext_temp_sensors[] = { +"Coolant temp" , +"External sensor" +}; + +static const char *const label_highflownext_fan_speed[] = { +"Flow [dL/h]" , +"Water quality [%]" , +"Conductivity [nS/cm]" , +}; + +static const char *const label_highflownext_power[] = { +"Dissipated power" , +}; + +static const char *const label_highflownext_voltage[] = { +"+5V voltage" , +"+5V USB voltage" +}; +struct aqc_data {struct hid_device *hdev;struct device *hwmon_dev;@@ -390,6 +423,11 @@ static umode_t aqc_is_visible(const void *data, enum hwmon_sensor_types type, u3break ;case hwmon_fan:switch (priv->kind) { +case highflownext: +/* Special case to support flow sensor, water quality and conductivity */ +if (channel <3 ) +return 0444 ; +break ;case quadro:/* Special case to support flow sensor */ if (channel < priv->num_fans +1 )@@ -402,6 +440,18 @@ static umode_t aqc_is_visible(const void *data, enum hwmon_sensor_types type, u3 }break ;case hwmon_power: +switch (priv->kind) { +case highflownext: +/* Special case to support one power sensor */ +if (channel ==0 ) +return 0444 ; +break ; +default : +if (channel < priv->num_fans) +return 0444 ; +break ; + } +break ;case hwmon_curr:if (channel < priv->num_fans)return 0444 ;@@ -413,6 +463,11 @@ static umode_t aqc_is_visible(const void *data, enum hwmon_sensor_types type, u3if (channel < priv->num_fans +2 )return 0444 ;break ; +case highflownext: +/* Special case to support two voltage sensors */ +if (channel <2 ) +return 0444 ; +break ;default :if (channel < priv->num_fans)return 0444 ;@@ -679,6 +734,22 @@ static int aqc_raw_event(struct hid_device *hdev, struct hid_report *report, u8case quadro: priv->speed_input[4 ] =get_unaligned_be16 (data + priv->flow_sensor_offset);break ; +case highflownext: +/* If external temp sensor is not connected, its power reading is also N/A */ +if (priv->temp_input[1 ] == -ENODATA ) + priv->power_input[0 ] = -ENODATA ; +else + priv->power_input[0 ] = +get_unaligned_be16 (data +HIGHFLOWNEXT_POWER ) *1000000 ; + + priv->voltage_input[0 ] =get_unaligned_be16 (data +HIGHFLOWNEXT_5V_VOLTAGE ) *10 ; + priv->voltage_input[1 ] = +get_unaligned_be16 (data +HIGHFLOWNEXT_5V_VOLTAGE_USB ) *10 ; + + priv->speed_input[0 ] =get_unaligned_be16 (data +HIGHFLOWNEXT_FLOW ); + priv->speed_input[1 ] =get_unaligned_be16 (data +HIGHFLOWNEXT_WATER_QUALITY ); + priv->speed_input[2 ] =get_unaligned_be16 (data +HIGHFLOWNEXT_CONDUCTIVITY ); +break ;default :break ; }@@ -851,6 +922,19 @@ static int aqc_probe(struct hid_device *hdev, const struct hid_device_id *id) priv->voltage_label = label_fan_voltage; priv->current_label = label_fan_current;break ; +case USB_PRODUCT_ID_HIGHFLOWNEXT : + priv->kind = highflownext; + + priv->num_fans =0 ; + priv->num_temp_sensors =HIGHFLOWNEXT_NUM_SENSORS ; + priv->temp_sensor_start_offset =HIGHFLOWNEXT_SENSOR_START ; + priv->power_cycle_count_offset =QUADRO_POWER_CYCLES ; + + priv->temp_label = label_highflownext_temp_sensors; + priv->speed_label = label_highflownext_fan_speed; + priv->power_label = label_highflownext_power; + priv->voltage_label = label_highflownext_voltage; +break ;default :break ; }@@ -907,6 +991,7 @@ static const struct hid_device_id aqc_table[] = { { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_FARBWERK360) }, { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_OCTO) }, { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_QUADRO) }, + { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_HIGHFLOWNEXT) }, { } };