timer: add SP804 DM_TIMER driver (and use it)
cover timer: add SP804 DM_TIMER driver (and use it)
Some boards were using an ARM SP804 timer IP, but were driving that using hardcoded addresses and input frequencies, using the CONFIG_SYS_TIMER_* macros. This is deprecated and scheduled for removal.
This series adds a DM_TIMER compliant SP804 driver in patch 1, and lets the Highbank board use that (patch 3).
Since the Highbank DT somewhat hides the timer base fixed-clock inside a subnode, we need some simple-bus like driver in patch 2 to help the driver find the timer frequency.
The SP804 driver should be usable by other SoCs using the SP804 timer, but I don't have any to test it there.
Cheers,
Andre
Andre Przywara (3):
timer: add SP804 UCLASS timer driver
highbank: scan into hb_sregs DT subnodes
highbank: switch to use the Arm SP804 DM_TIMER driver
arch/arm/Kconfig | 2 + board/highbank/Makefile | 2 +- board/highbank/hb_sregs.c | 45 +++++++++++++++ drivers/timer/Kconfig | 6 ++ drivers/timer/Makefile | 1 + drivers/timer/sp804_timer.c | 108 ++++++++++++++++++++++++++++++++++++ include/configs/highbank.h | 4 -- 7 files changed, 163 insertions(+), 5 deletions(-) create mode 100644 board/highbank/hb_sregs.c create mode 100644 drivers/timer/sp804_timer.c
Signature · 1 line
2.25.1
PATCH 1/3 timer: add SP804 UCLASS timer driver
The "Arm Ltd. Dual-Timer Module (SP804)" is a simple 32-bit count-down timer IP with interrupt functionality, and is used in some SoCs from various vendors.
Add a simple DM compliant timer driver, to allow users of the SP804 to switch to DM_TIMER.
This relies on the input clock to be accessible via the DM clock framework, which should be fine as we probably look at fixed-clock's here anyway.
We re-program the control register in the probe() function, but keep the divider in place, in case this has been set to something on purpose before.
The TRM for the timer IP can be found here:
https://developer.arm.com/documentation/ddi0271/latest
--- drivers/timer/Kconfig | 6 ++ drivers/timer/Makefile | 1 + drivers/timer/sp804_timer.c | 108 ++++++++++++++++++++++++++++++++++++ 3 files changed, 115 insertions(+) create mode 100644 drivers/timer/sp804_timer.c
drivers/timer/Kconfig +6 -0
@@ -230,6 +230,12 @@ config SANDBOX_TIMER Select this to enable an emulated timer for sandbox. It gets time from host os. +config SP804_TIMER + bool "ARM SP804 timer support" + depends on TIMER + help + ARM SP804 dual timer IP support + config STI_TIMER bool "STi timer support" depends on TIMER
drivers/timer/Makefile +1 -0
@@ -23,6 +23,7 @@ obj-$(CONFIG_RENESAS_OSTM_TIMER) += ostm_timer.o obj-$(CONFIG_RISCV_TIMER) += riscv_timer.o obj-$(CONFIG_ROCKCHIP_TIMER) += rockchip_timer.o obj-$(CONFIG_SANDBOX_TIMER) += sandbox_timer.o +obj-$(CONFIG_SP804_TIMER) += sp804_timer.o obj-$(CONFIG_$(SPL_)SIFIVE_CLINT) += sifive_clint_timer.o obj-$(CONFIG_STI_TIMER) += sti-timer.o obj-$(CONFIG_STM32_TIMER) += stm32_timer.o
drivers/timer/sp804_timer.c new file +108 -0
108 lines not on this page · raw message
Signature · 1 line
2.25.1
Re: [PATCH 1/3] timer: add SP804 UCLASS timer driver
Quoted 14 lines · Andre Przywara
The "Arm Ltd. Dual-Timer Module (SP804)" is a simple 32-bit count-down timer IP with interrupt functionality, and is used in some SoCs from various vendors.
Add a simple DM compliant timer driver, to allow users of the SP804 to switch to
DM_TIMER.This relies on the input clock to be accessible via the DM clock framework, which should be fine as we probably look at fixed-clock's here anyway.
We re-program the control register in theprobe()function, but keep the divider in place, in case this has been set to something on purpose before.
Quoted 4 lines
The TRM for the timer IP can be found here:
https://developer.arm.com/documentation/ddi0271/latestSigned-off-by Andre Przywara <[email protected]>
Applied to u-boot/master, thanks!
Signature · 1 line
Tom
PATCH 2/3 highbank: scan into hb_sregs DT subnodes
In reply to Andre PrzywaraThe DT used for Calxeda Highbank and Midway systems exposes a "system registers" block, modeled as a DT subnode.
This includes several clocks, including the two fixed clocks for the main oscillator and timer.
So far U-Boot was ignorant of this special construct (a "clocks" node within the "hb-sregs" node), as it didn't need the PLL clocks in there. But that also meant we lost the fixed clocks, which form the base for the UART baudrate generator and also the SP804 timer.
To allow the generic PL011 and SP804 driver to read the clock rate, add a simple bus driver, which triggers the DT node discovery inside this special node. As we only care about the fixed clocks (we don't have drivers for the PLLs anyway), just ignore the address translation (for now).
The binding is described in bindings/arm/calxeda/hb-sregs.yaml, the DT snippet in question looks like:
=======================
sregs@fff3c000 {
compatible = "calxeda,hb-sregs";
reg = <0xfff3c000 0x1000>;
clocks {
#address-cells = <1>;
#size-cells = <0>;
osc: oscillator {
#clock-cells = <0>;
compatible = "fixed-clock";
clock-frequency = <33333000>;
};
....
};
};=======================
--- board/highbank/Makefile | 2 +- board/highbank/hb_sregs.c | 45 +++++++++++++++++++++++++++++++++++++++ 2 files changed, 46 insertions(+), 1 deletion(-) create mode 100644 board/highbank/hb_sregs.c
board/highbank/Makefile +1 -1
@@ -3,4 +3,4 @@ # (C) Copyright 2000-2006 # Wolfgang Denk, DENX Software Engineering, [email protected]. -obj-y := highbank.o ahci.o +obj-y := highbank.o ahci.o hb_sregs.o
board/highbank/hb_sregs.c new file +45 -0
45 lines not on this page · raw message
Signature · 1 line
2.25.1
Re: [PATCH 2/3] highbank: scan into hb_sregs DT subnodes
Quoted 36 lines · Andre Przywara
The DT used for Calxeda Highbank and Midway systems exposes a "system registers" block, modeled as a DT subnode.
This includes several clocks, including the two fixed clocks for the main oscillator and timer.So far U-Boot was ignorant of this special construct (a "clocks" node within the "hb-sregs" node), as it didn't need the PLL clocks in there. But that also meant we lost the fixed clocks, which form the base for the UART baudrate generator and also the SP804 timer.
To allow the generic PL011 and SP804 driver to read the clock rate, add a simple bus driver, which triggers the DT node discovery inside this special node. As we only care about the fixed clocks (we don't have drivers for the PLLs anyway), just ignore the address translation (for now).
The binding is described in
bindings/arm/calxeda/hb-sregs.yaml, the DT snippet in question looks like:=======================
sregs@fff3c000 { compatible = "calxeda,hb-sregs"; reg = <0xfff3c000 0x1000>; clocks { #address-cells = <1>; #size-cells = <0>; osc: oscillator { #clock-cells = <0>; compatible = "fixed-clock"; clock-frequency = <33333000>; }; .... }; };
Quoted 3 lines
=======================
Signed-off-by Andre Przywara <[email protected]>
Applied to u-boot/master, thanks!
Signature · 1 line
Tom
PATCH 3/3 highbank: switch to use the Arm SP804 DM_TIMER driver
In reply to Andre PrzywaraSo far the Calxeda machines were using the CONFIG_SYS_TIMER_* macros to simply hardcode the address of the counter register of the SP804 timer. This method is deprecated and scheduled for removal.
Use the newly introduced SP804 DM_TIMER driver to provide timer functionality on Highbank and Midway machines. The base address and base frequency are taken from the devicetree.
--- arch/arm/Kconfig | 2 ++ include/configs/highbank.h | 4 ---- 2 files changed, 2 insertions(+), 4 deletions(-)
arch/arm/Kconfig +2 -0
@@ -793,6 +793,8 @@ config ARCH_HIGHBANK select AHCI select DM_ETH select PHYS_64BIT + select TIMER + select SP804_TIMER imply OF_HAS_PRIOR_STAGE config ARCH_INTEGRATOR
include/configs/highbank.h +0 -4
@@ -8,10 +8,6 @@#define CONFIG_SYS_BOOTMAPSZ (16 << 20) -#define CONFIG_SYS_TIMER_RATE (150000000/256) -#define CONFIG_SYS_TIMER_COUNTER (0xFFF34000 + 0x4) -#define CONFIG_SYS_TIMER_COUNTS_DOWN -#define CONFIG_PL011_CLOCK 150000000/*
Signature · 1 line
2.25.1
Re: [PATCH 3/3] highbank: switch to use the Arm SP804 DM_TIMER driver
Quoted 9 lines · Andre Przywara
So far the Calxeda machines were using the CONFIG_SYS_TIMER_* macros to simply hardcode the address of the counter register of the SP804 timer. This method is deprecated and scheduled for removal.
Use the newly introduced SP804
DM_TIMERdriver to provide timer functionality on Highbank and Midway machines. The base address and base frequency are taken from the devicetree.Signed-off-by Andre Przywara <[email protected]>
Applied to u-boot/master, thanks!
Signature · 1 line
Tom