dt-bindings: watchdog: gpio: Convert bindings to YAML

PATCH Superseded Marek Vasut 2 participants 2 messages Nov 2, 2022 – Nov 4, 2022

Subsystems (2)

v2 of 3 Superseded Latest is v3 →

lore
Share & tools
lore
#0 lore raw

PATCH v2 1/1 dt-bindings: watchdog: gpio: Convert bindings to YAML

Convert the gpio-wdt bindings from text to YAML ones, to permit DT validation.

---
Cc: Guenter Roeck <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: Wim Van Sebroeck <[email protected]>
Cc: [email protected]
To: [email protected]
---
V2: - Add missing required: properties
- Drop quotes around ref: referenced schema file name
---
NOTE: The Maintainer entry should likely be changed, although it seems
like this driver and its matching bindings are now unmaintained.

---
 .../devicetree/bindings/watchdog/gpio-wdt.txt | 28 -----------
 .../bindings/watchdog/linux,wdt-gpio.yaml     | 47 +++++++++++++++++++
 2 files changed, 47 insertions(+), 28 deletions(-)
 delete mode 100644 Documentation/devicetree/bindings/watchdog/gpio-wdt.txt
 create mode 100644 Documentation/devicetree/bindings/watchdog/linux,wdt-gpio.yaml
Documentation/devicetree/bindings/watchdog/gpio-wdt.txt deleted +0 -28
deleted file mode 100644
index 198794963786b..0000000000000
@@ -1,28 +0,0 @@
-* GPIO-controlled Watchdog
-
-Required Properties:
-- compatible: Should contain "linux,wdt-gpio".
-- gpios: From common gpio binding; gpio connection to WDT reset pin.
-- hw_algo: The algorithm used by the driver. Should be one of the
-  following values:
-  - toggle: Either a high-to-low or a low-to-high transition clears
-    the WDT counter. The watchdog timer is disabled when GPIO is
-    left floating or connected to a three-state buffer.
-  - level: Low or high level starts counting WDT timeout,
-    the opposite level disables the WDT. Active level is determined
-    by the GPIO flags.
-- hw_margin_ms: Maximum time to reset watchdog circuit (milliseconds).
-
-Optional Properties:
-- always-running: If the watchdog timer cannot be disabled, add this flag to
-  have the driver keep toggling the signal without a client. It will only cease
-  to toggle the signal when the device is open and the timeout elapsed.
-
-Example:
-	watchdog: watchdog {
-		/* ADM706 */
-		compatible = "linux,wdt-gpio";
-		gpios = <&gpio3 9 GPIO_ACTIVE_LOW>;
-		hw_algo = "toggle";
-		hw_margin_ms = <1600>;
-	};
Documentation/devicetree/bindings/watchdog/linux,wdt-gpio.yaml new file +47 -0

47 lines not on this page · raw message

Signature · 1 line
2.35.1
maintainer Reviewed-by on v2 1/1
#1 lore raw
Quoted 15 lines · Marek Vasut

Convert the gpio-wdt bindings from text to YAML ones, to permit DT validation.

---
Cc: Guenter Roeck <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: Wim Van Sebroeck <[email protected]>
Cc: [email protected]
To: [email protected]
---
V2: - Add missing required: properties
- Drop quotes around ref: referenced schema file name
---
NOTE: The Maintainer entry should likely be changed, although it seems
like this driver and its matching bindings are now unmaintained.

Quoted 7 lines
---
 .../devicetree/bindings/watchdog/gpio-wdt.txt | 28 -----------
 .../bindings/watchdog/linux,wdt-gpio.yaml     | 47 +++++++++++++++++++
 2 files changed, 47 insertions(+), 28 deletions(-)
 delete mode 100644 Documentation/devicetree/bindings/watchdog/gpio-wdt.txt
 create mode 100644 Documentation/devicetree/bindings/watchdog/linux,wdt-gpio.yaml