s390: ipl: fix physical-virtual confusion for diag308
v2 cover s390: ipl: fix physical-virtual confusion for diag308
v2:
---
* add special handling for addr NULL (thanks Alexander)
Nico Boehr (1):
s390: ipl: fix physical-virtual confusion for diag308
arch/s390/kernel/ipl.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
Signature · 1 line
2.39.1
PATCH v2 1/1 s390: ipl: fix physical-virtual confusion for diag308
Diag 308 subcodes expect a physical address as their parameter.
This currently is not a bug, but in the future physical and virtual addresses might differ.
Fix the confusion by doing a virtual-to-physical conversion in the exported diag308() and leave the assembly wrapper __diag308() alone.
Note that several callers pass NULL as addr, this is _currently_ fine since virt_to_phys(0) == 0. But in the future, lowcore addresses might no longer be special, so make sure we pass 0 to hardware in case addr is NULL.
--- arch/s390/kernel/ipl.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
arch/s390/kernel/ipl.c +2 -2
@@ -176,7 +176,7 @@ static bool reipl_fcp_clear;static bool reipl_ccw_clear;static bool reipl_eckd_clear; -static inline int __diag308 (unsigned long subcode,void *addr) +static inline int __diag308 (unsigned long subcode,u64 addr) {union register_pair r1;
@@ -195,7 +195,7 @@ static inline int __diag308(unsigned long subcode, void *addr)int diag308 (unsigned long subcode,void *addr) {diag_stat_inc (DIAG_STAT_X308 ); -return __diag308 (subcode, addr); +return __diag308 (subcode, addr ?virt_to_phys (addr) :0 ); }EXPORT_SYMBOL_GPL (diag308);
Signature · 1 line
2.39.1
Alexander Gordeev
maintainerQuoted 7 lines · Nico Boehr
Diag 308 subcodes expect a physical address as their parameter.
This currently is not a bug, but in the future physical and virtual addresses might differ.
Fix the confusion by doing a virtual-to-physical conversion in the exported
diag308()and leave the assembly wrapper__diag308()alone.
You change the prototype though ;)
Quoted 4 lines
Note that several callers pass NULL as addr, this is _currently_ fine since
virt_to_phys(0)== 0. But in the future, lowcore addresses might no longer be special, so make sure we pass 0 to hardware in case addr is NULL.
This paragraph seems to me is extra or not precise at least. The reason for explicit NULL check is not virt_to_phys(NULL) might return non-0 in the future, but rather virt_to_phys(NULL) is not expected returning 0 on any architecture.
Quoted 11 lines
Suggested-by Marc Hartmayer <[email protected]>Signed-off-by Nico Boehr <[email protected]>--- arch/s390/kernel/ipl.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)arch/s390/kernel/ipl.c +0
-0
arch/s390/kernel/ipl.c static bool reipl_fcp_clear; · line 179
Quoted 5 lines
arch/s390/kernel/ipl.c +1
-1@@ -176,7 +176,7 @@ static bool reipl_fcp_clear;static bool reipl_ccw_clear;static bool reipl_eckd_clear; -static inline int __diag308 (unsigned long subcode,void *addr) +static inline int __diag308 (unsigned long subcode,u64 addr)
Physical addresses are unsigned longs. Why u64 then? Also the cast to unsigned long (not seen here) becomes redundant.
Quoted 2 lines
arch/s390/kernel/ipl.c +0
-0{union register_pair r1;