mips: Use of_property_read_bool() for boolean properties
PATCH 1/1 mips: Use of_property_read_bool() for boolean properties
It is preferred to use typed property access functions (i.e. of_property_read_<type> functions) rather than low-level of_get_property/of_find_property functions for reading properties. Convert reading boolean properties to to of_property_read_bool().
--- arch/mips/pci/pci-lantiq.c | 2 +- arch/mips/pci/pci-rt3883.c | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-)
arch/mips/pci/pci-lantiq.c +1 -1
@@ -118,7 +118,7 @@ static int ltq_pci_startup(struct platform_device *pdev)/* and enable the clocks */ clk_enable (clk_pci); -if (of_find_property (node,"lantiq,external-clock" ,NULL )) +if (of_property_read_bool (node,"lantiq,external-clock" ))clk_enable (clk_external);else clk_disable (clk_external);
arch/mips/pci/pci-rt3883.c +1 -1
@@ -419,7 +419,7 @@ static int rt3883_pci_probe(struct platform_device *pdev)/* find the interrupt controller child node */ for_each_child_of_node (np, child) { -if (of_get_property (child,"interrupt-controller" ,NULL )) { +if (of_property_read_bool (child,"interrupt-controller" )) { rpc->intc_of_node = child;break ; }
Signature · 1 line
2.39.2
Hi Rob,
Quoted 16 lines · Rob Herring
It is preferred to use typed property access functions (i.e. of_property_read_<type> functions) rather than low-level of_get_property/of_find_property functions for reading properties. Convert reading boolean properties to to
of_property_read_bool().Signed-off-by Rob Herring <[email protected]>--- arch/mips/pci/pci-lantiq.c | 2 +- arch/mips/pci/pci-rt3883.c | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-)arch/mips/pci/pci-lantiq.c +0
-0
arch/mips/pci/pci-lantiq.c static int ltq_pci_startup(struct platform_device *pdev) · line 121
Quoted 5 lines
arch/mips/pci/pci-lantiq.c +1
-1@@ -118,7 +118,7 @@ static int ltq_pci_startup(struct platform_device *pdev)/* and enable the clocks */ clk_enable (clk_pci); -if (of_find_property (node,"lantiq,external-clock" ,NULL )) +if (of_property_read_bool (node,"lantiq,external-clock" ))
Just curious, is this property correct? I can't find it and wonder if this is dead code (always disabling the clock)... I'm probably missing something obvious :/
Quoted 3 lines
arch/mips/pci/pci-lantiq.c +0
-0clk_enable (clk_external); elseclk_disable (clk_external );
Hi,
Quoted 21 lines · Philippe Mathieu-Daudé
Hi Rob,
Quoted 17 lines · Rob Herring
It is preferred to use typed property access functions (i.e. of_property_read_<type> functions) rather than low-level of_get_property/of_find_property functions for reading properties. Convert reading boolean properties to to
of_property_read_bool().Signed-off-by Rob Herring <[email protected]>--- arch/mips/pci/pci-lantiq.c | 2 +- arch/mips/pci/pci-rt3883.c | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-)arch/mips/pci/pci-lantiq.c +0
-0@@ -118,7 +118,7 @@ static int ltq_pci_startup(struct platform_device *pdev)
Quoted 12 lines
arch/mips/pci/pci-lantiq.c static int ltq_pci_startup(struct platform_device *pdev) · line 121
Quoted 4 lines
arch/mips/pci/pci-lantiq.c +1
-1/* and enable the clocks */ clk_enable (clk_pci); -if (of_find_property (node,"lantiq,external-clock" ,NULL )) +if (of_property_read_bool (node,"lantiq,external-clock" ))Just curious, is this property correct? I can't find it and wonder if this is dead code (always disabling the clock)... I'm probably missing something obvious :/
Quoted 3 lines
arch/mips/pci/pci-lantiq.c +0
-0clk_enable (clk_external); elseclk_disable (clk_external );
The (whole) binding does seem to be undocumented, at least a quick grep didn't find anything for "lantiq,pci-xway" in bindings :-/
The property itself is used in OpenWrt though, e.g.
https://github.com/openwrt/openwrt/blob/master/target/linux/lantiq/files/arch/mips/boot/dts/lantiq/danube_arcadyan_arv7518pw.dts#L209
Regards
Jonas
Quoted 21 lines · Philippe Mathieu-Daudé
Hi Rob,
Quoted 17 lines · Rob Herring
It is preferred to use typed property access functions (i.e. of_property_read_<type> functions) rather than low-level of_get_property/of_find_property functions for reading properties. Convert reading boolean properties to to
of_property_read_bool().Signed-off-by Rob Herring <[email protected]>--- arch/mips/pci/pci-lantiq.c | 2 +- arch/mips/pci/pci-rt3883.c | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-)arch/mips/pci/pci-lantiq.c +0
-0@@ -118,7 +118,7 @@ static int ltq_pci_startup(struct platform_device *pdev)
Quoted 6 lines
arch/mips/pci/pci-lantiq.c static int ltq_pci_startup(struct platform_device *pdev) · line 121
Quoted 4 lines
arch/mips/pci/pci-lantiq.c +1
-1/* and enable the clocks */ clk_enable (clk_pci); -if (of_find_property (node,"lantiq,external-clock" ,NULL )) +if (of_property_read_bool (node,"lantiq,external-clock" ))Just curious, is this property correct?
Shrug. I can only tell from how it is used here and because we have other similar properties used to select a clock.
Quoted 3 lines
I can't find it and wonder if
this is dead code (always disabling the clock)... I'm probably missing something obvious :/
If you don't use the external clock, then you disable it. Seems sensible to me.
Quoted 5 lines
Quoted 4 lines
arch/mips/pci/pci-lantiq.c +0
-0clk_enable (clk_external); elseclk_disable (clk_external );
Quoted 10 lines · Rob Herring
It is preferred to use typed property access functions (i.e. of_property_read_<type> functions) rather than low-level of_get_property/of_find_property functions for reading properties. Convert reading boolean properties to to
of_property_read_bool().Signed-off-by Rob Herring <[email protected]>--- arch/mips/pci/pci-lantiq.c | 2 +- arch/mips/pci/pci-rt3883.c | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-)
applied to mips-next.
Thomas.