scsi: sd: support specify probe type of build-in driver

PATCH In review Jianlin Lv 3 participants 10 messages Jun 6, 2023 – Jun 25, 2023

Subsystems (2)
lore
Share & tools
lore

Jianlin Lv

author
#0 lore raw

PATCH 1/1 scsi: sd: support specify probe type of build-in driver

When SCSI disks are located on different SCSI hosts within a system, asynchronous detection can lead to non-deterministic SCSI disk names.

This patch introduces the 'sd_probe_type=' kernel boot parameter.

In scenarios where SCSI disk name sensitivity is crucial, the probe type of the build-in sd driver can be set to synchronous. As a result, the scsi disk names are deterministic.

---
 .../admin-guide/kernel-parameters.txt         |  9 ++++++++
 drivers/scsi/sd.c                             | 23 +++++++++++++++++++
 2 files changed, 32 insertions(+)
Documentation/admin-guide/kernel-parameters.txt +9 -0
index 9e5bab29685f..083f741d63bb 100644
@@ -5611,6 +5611,15 @@
 			non-zero "wait" parameter.  See weight_single
 			and weight_many.
 
+	sd_probe_type=	[HW,SCSI] Manual setup probe type of built-in scsi disk driver
+			Format: <int>
+			Default: 1
+			<int> -- device driver probe type to try
+				0 - PROBE_DEFAULT_STRATEGY
+				1 - PROBE_PREFER_ASYNCHRONOUS
+				2 - PROBE_FORCE_SYNCHRONOUS
+			Example: sd_probe_type=1
+
 	skew_tick=	[KNL] Offset the periodic timer tick per cpu to mitigate
 			xtime_lock contention on larger systems, and/or RCU lock
 			contention on all systems with CONFIG_MAXSMP set.
drivers/scsi/sd.c +23 -0
index 1624d528aa1f..78b80b9e5618 100644
@@ -121,6 +121,9 @@ static void scsi_disk_release(struct device *cdev);
 
 static DEFINE_IDA(sd_index_ida);
 
+/* Probe type of SCSI Disk Driver */
+static int sd_probe_type = PROBE_PREFER_ASYNCHRONOUS;
+
 static mempool_t *sd_page_pool;
 static struct lock_class_key sd_bio_compl_lkclass;
 
@@ -3826,6 +3829,25 @@ static int sd_resume_runtime(struct device *dev)
 	return sd_resume(dev);
 }
 
+#ifndef MODULE
+
+/* Set the boot options to sd driver.
+ * Syntax is defined in Documentation/admin-guide/kernel-parameters.txt.
+ */
+static int __init sd_probe_setup(char *str)
+{
+	int probe_type = -1;
+
+	if (get_option(&str, &probe_type) && probe_type >= 0 && probe_type < 3)
+		sd_probe_type = probe_type;
+
+	return 1;
+}
+
+__setup("sd_probe_type=", sd_probe_setup);
+
+#endif
+
 /**
  *	init_sd - entry point for this driver (both when built in or when
  *	a module).
@@ -3858,6 +3880,7 @@ static int __init init_sd(void)
 		goto err_out_class;
 	}
 
+	sd_template.gendrv.probe_type = sd_probe_type;
 	err = scsi_register_driver(&sd_template.gendrv);
 	if (err)
 		goto err_out_driver;
Signature · 1 line
2.25.1
#1 lore raw
Quoted 3 lines · Jianlin Lv

In scenarios where SCSI disk name sensitivity is crucial, the probe type of the build-in sd driver can be set to synchronous. As a result, the scsi disk names are deterministic.

Which are these scenarios?

Additionally, how can synchronous scanning of sd devices make a difference if there are multiple host bus adapters that use an interface type that is scanned asynchronously?

Bart.

author
#2 lore raw
Quoted 6 lines · Bart Van Assche
Quoted 3 lines · Jianlin Lv

In scenarios where SCSI disk name sensitivity is crucial, the probe type of the build-in sd driver can be set to synchronous. As a result, the scsi disk names are deterministic.

Quoted 7 lines

Which are these scenarios?

Additionally, how can synchronous scanning of sd devices make a difference if there are multiple host bus adapters that use an interface type that is scanned asynchronously?

Bart.

The change was prompted by an issue with SCSI devices probing non-deterministic. On the issue node, there are two types of SCSI hosts:

1. MegaRAID adapters associated with 24 local disks. The disks are named sequentially as "sda," "sdb," and so on, up to "sdx."
2. STAT controllers associated with the root disk, named "sdy."

Both the MegaRAID adapters and the SATA controller (PCH) are accessed via the PCIe bus. In theory, depending on their PCIe bus ID in ascending order, the devices should be initialized in ascending order as well.

However, the SCSI driver currently probes devices asynchronously to allow for more parallelism.

__driver_attach
->if (driver_allows_async_probing(drv))

      async_schedule_dev(__driver_attach_async_helper, dev);

During the probing of SCSI disks attached to MegaRAID, root disk probing may occur, resulting in a disk naming inconsistency issue.
For example, if root disk probing happens in the middle,it is named "sdq", The subsequent SCSI disks that are probed will have their names drift, starting from "sdr" up to "sdy."

For cloud deployment, the local volume provisioner detects and creates PVs for each local disk (from sda to sdx) on the host, and it cleans up the disks when they are released.
This requires the logical names of the disks to be deterministic.

Therefore, I have submitted this patch to allow users to configure the SCSI disk probe type.
If synchronous probing is configured, the SCSI disk probing order is deterministic and will follow the ascending order of the PCIe bus ID.

Jianlin

#3 lore raw
Quoted 7 lines · Jianlin Lv

1. MegaRAID adapters associated with 24 local disks. The disks are named sequentially as "sda," "sdb," and so on, up to "sdx."
2. STAT controllers associated with the root disk, named "sdy."

Both the MegaRAID adapters and the SATA controller (PCH) are accessed via the PCIe bus. In theory, depending on their PCIe bus ID in ascending order, the devices should be initialized in ascending order as well.

Hmm ... I don't think there is anything that prevents the PCIe maintainer from changing the PCIe probing behavior from synchronous to asynchronous? In other words, I don't think it is safe to assume that PCIe devices are always scanned in the same order.

Quoted 4 lines

For cloud deployment, the local volume provisioner detects and creates PVs for each local disk (from sda to sdx) on the host, and it cleans up the disks when they are released.
This requires the logical names of the disks to be deterministic.

I see two possible solutions:
- Change the volume provisioner such that it uses disk references that do not depend on the probing order, e.g. /dev/disk/by-id/...
- Implement an algorithm in systemd that makes disk names predictable. An explanation of how predictable names work for network interfaces is available here: https://wiki.debian.org/NetworkInterfaceNames. The systemd documentation about predictable network names is available here:
https://www.freedesktop.org/software/systemd/man/systemd.net-naming-scheme.html

These alternatives have the advantage that disk scanning remains asynchronous.

Thanks,

Bart.

author
#4 lore raw
Quoted 15 lines · Bart Van Assche
Quoted 7 lines · Jianlin Lv

1. MegaRAID adapters associated with 24 local disks. The disks are named sequentially as "sda," "sdb," and so on, up to "sdx."
2. STAT controllers associated with the root disk, named "sdy."

Both the MegaRAID adapters and the SATA controller (PCH) are accessed via the PCIe bus. In theory, depending on their PCIe bus ID in ascending order, the devices should be initialized in ascending order as well.

Hmm ... I don't think there is anything that prevents the PCIe maintainer from changing the PCIe probing behavior from synchronous to asynchronous? In other words, I don't think it is safe to assume that PCIe devices are always scanned in the same order.

Quoted 8 lines
Quoted 4 lines

For cloud deployment, the local volume provisioner detects and creates PVs for each local disk (from sda to sdx) on the host, and it cleans up the disks when they are released.
This requires the logical names of the disks to be deterministic.

I see two possible solutions:
- Change the volume provisioner such that it uses disk references that do not depend on the probing order, e.g. /dev/disk/by-id/...

Yes, The "/dev/disk/by-id/" can uniquely identify SCSI devices. However, I don't think it is suitable for the volume provisioner workflow. For nodes of the same SKU , a unified YAML file will be defined to instruct the volume provisioner on how to manage the local disks.
If use WWID, it would mean that a unique YAML file needs to be defined for each node. This approach becomes impractical when dealing with a large number of work nodes.

Jianlin

Quoted 12 lines

- Implement an algorithm in systemd that makes disk names predictable. An explanation of how predictable names work for network interfaces is available here: https://wiki.debian.org/NetworkInterfaceNames. The systemd documentation about predictable network names is available here:
https://www.freedesktop.org/software/systemd/man/systemd.net-naming-scheme.html

These alternatives have the advantage that disk scanning remains asynchronous.

Thanks,

Bart.

#5 lore raw
Quoted 6 lines · Jianlin Lv
Quoted 4 lines · Bart Van Assche

On 6/7/23 08:55, Jianlin Lv wrote:
I see two possible solutions:
- Change the volume provisioner such that it uses disk references that do not depend on the probing order, e.g. /dev/disk/by-id/...

Quoted 7 lines

Yes, The "/dev/disk/by-id/" can uniquely identify SCSI devices. However, I don't think it is suitable for the volume provisioner workflow. For nodes of the same SKU , a unified YAML file will be defined to instruct the volume provisioner on how to manage the local disks.
If use WWID, it would mean that a unique YAML file needs to be defined for each node. This approach becomes impractical when dealing with a large number of work nodes.

Please consider using the paths available in /dev/disk/by-path.

Thanks,

Bart.

author
#6 lore raw
Quoted 8 lines · Bart Van Assche
Quoted 6 lines · Jianlin Lv
Quoted 4 lines · Bart Van Assche

On 6/7/23 08:55, Jianlin Lv wrote:
I see two possible solutions:
- Change the volume provisioner such that it uses disk references that do not depend on the probing order, e.g. /dev/disk/by-id/...

Quoted 8 lines
Quoted 7 lines

Yes, The "/dev/disk/by-id/" can uniquely identify SCSI devices. However, I don't think it is suitable for the volume provisioner workflow. For nodes of the same SKU , a unified YAML file will be defined to instruct the volume provisioner on how to manage the local disks.
If use WWID, it would mean that a unique YAML file needs to be defined for each node. This approach becomes impractical when dealing with a large number of work nodes.

Please consider using the paths available in /dev/disk/by-path.

Sorry for the late reply.
I carefully checked the server in the production environment and found some corner cases where there are differences in the dev/disk/by-path/ of nodes with the same SKU. These differences are caused by inconsistent target_numbers.

For example:

diff -y aa-by-path bb-by-path
pci-0000:86:00.0-scsi-0:3:86:0 -> ../../sda |
pci-0000:86:00.0-scsi-0:3:88:0 -> ../../sda
pci-0000:86:00.0-scsi-0:3:87:0 -> ../../sdb |
pci-0000:86:00.0-scsi-0:3:89:0 -> ../../sdb
pci-0000:86:00.0-scsi-0:3:88:0 -> ../../sdc |
pci-0000:86:00.0-scsi-0:3:90:0 -> ../../sdc
pci-0000:86:00.0-scsi-0:3:89:0 -> ../../sdd |
pci-0000:86:00.0-scsi-0:3:91:0 -> ../../sdd
pci-0000:86:00.0-scsi-0:3:90:0 -> ../../sde |
pci-0000:86:00.0-scsi-0:3:92:0 -> ../../sde
pci-0000:86:00.0-scsi-0:3:92:0 -> ../../sdf |
pci-0000:86:00.0-scsi-0:3:93:0 -> ../../sdf
pci-0000:86:00.0-scsi-0:3:93:0 -> ../../sdg |
pci-0000:86:00.0-scsi-0:3:94:0 -> ../../sdg
pci-0000:86:00.0-scsi-0:3:94:0 -> ../../sdh |
pci-0000:86:00.0-scsi-0:3:95:0 -> ../../sdh

I'm still not sure what causes the target_numbers to be different. However, the existence of such corner cases makes /dev/disk/by-path unusable for the volume provisioner, similar to /dev/disk/by-id/.

So, If it's not possible to configure disk serialization detection, then it seems that implementing predictable disk names is the only option.

Jianlin

Quoted 4 lines

Thanks,

Bart.

#7 lore raw
Quoted 44 lines · Jianlin Lv
Quoted 8 lines · Bart Van Assche
Quoted 6 lines · Jianlin Lv
Quoted 4 lines · Bart Van Assche

On 6/7/23 08:55, Jianlin Lv wrote:
I see two possible solutions:
- Change the volume provisioner such that it uses disk references that do not depend on the probing order, e.g. /dev/disk/by-id/...

Quoted 8 lines
Quoted 7 lines

Yes, The "/dev/disk/by-id/" can uniquely identify SCSI devices. However, I don't think it is suitable for the volume provisioner workflow. For nodes of the same SKU , a unified YAML file will be defined to instruct the volume provisioner on how to manage the local disks.
If use WWID, it would mean that a unique YAML file needs to be defined for each node. This approach becomes impractical when dealing with a large number of work nodes.

Please consider using the paths available in /dev/disk/by-path.

Sorry for the late reply.
I carefully checked the server in the production environment and found some corner cases where there are differences in the dev/disk/by-path/ of nodes with the same SKU. These differences are caused by inconsistent target_numbers.

For example:

diff -y aa-by-path bb-by-path
pci-0000:86:00.0-scsi-0:3:86:0 -> ../../sda |
pci-0000:86:00.0-scsi-0:3:88:0 -> ../../sda
pci-0000:86:00.0-scsi-0:3:87:0 -> ../../sdb |
pci-0000:86:00.0-scsi-0:3:89:0 -> ../../sdb
pci-0000:86:00.0-scsi-0:3:88:0 -> ../../sdc |
pci-0000:86:00.0-scsi-0:3:90:0 -> ../../sdc
pci-0000:86:00.0-scsi-0:3:89:0 -> ../../sdd |
pci-0000:86:00.0-scsi-0:3:91:0 -> ../../sdd
pci-0000:86:00.0-scsi-0:3:90:0 -> ../../sde |
pci-0000:86:00.0-scsi-0:3:92:0 -> ../../sde
pci-0000:86:00.0-scsi-0:3:92:0 -> ../../sdf |
pci-0000:86:00.0-scsi-0:3:93:0 -> ../../sdf
pci-0000:86:00.0-scsi-0:3:93:0 -> ../../sdg |
pci-0000:86:00.0-scsi-0:3:94:0 -> ../../sdg
pci-0000:86:00.0-scsi-0:3:94:0 -> ../../sdh |
pci-0000:86:00.0-scsi-0:3:95:0 -> ../../sdh

Quoted 6 lines

I'm still not sure what causes the target_numbers to be different. However, the existence of such corner cases makes /dev/disk/by-path unusable for the volume provisioner, similar to /dev/disk/by-id/.

So, If it's not possible to configure disk serialization detection, then it seems that implementing predictable disk names is the only option.

I think the following code from the systemd source file src/udev/udev-builtin-path_id.c generates the last part of the path ID:

	[ ... ]
        if (sscanf(name, "%d:%d:%d:%d", &host, &bus, &target, &lun)!=4)
		return NULL;
	[ ... ]
        path_prepend(path, "scsi-%i:%i:%i:%i", host, bus, target, lun);
	[ ... ]

Is megasas_add_remove_devices() the code that adds SCSI devices on your setup? In that code I see that scsi_device_lookup() is called in a loop until channel and target numbers are found that are not in use. I think this is what makes the target numbers unpredictable on your setup. There must be a better way for the megaraid driver to assign a target number.

Bart.

#8 lore raw
In reply to Jianlin Lv
Quoted 2 lines · Jianlin Lv

When SCSI disks are located on different SCSI hosts within a system, asynchronous detection can lead to non-deterministic SCSI disk names.

Yes, as can various other conditions. Your code better be able to deal with that.

author
#9 lore raw
Quoted 7 lines · Christoph Hellwig
Quoted 2 lines · Jianlin Lv

When SCSI disks are located on different SCSI hosts within a system, asynchronous detection can lead to non-deterministic SCSI disk names.

Yes, as can various other conditions. Your code better be able to deal with that.

Could you give an example about "other conditions" ?

Jianlin