Skip to contentSkip to conversation

thermal/drivers/mediatek/lvts_thermal: Make readings valid in filtered mode

PATCH Applied Nícolas F. R. A. Prado 4 participants 5 messages Jul 13, 2023 – Aug 16, 2023

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH v2 1/1 thermal/drivers/mediatek/lvts_thermal: Make readings valid in filtered mode

Currently, when a controller is configured to use filtered mode, thermal readings are valid only about 30% of the time.

Upon testing, it was noticed that lowering any of the interval settings resulted in an improved rate of valid data. The same was observed when decreasing the number of samples for each sensor (which also results in quicker measurements).

Retrying the read with a timeout longer than the time it takes to resample (about 344us with these settings and 4 sensors) also improves the rate.

Lower all timing settings to the minimum, configure the filtering to single sample, and poll the measurement register for at least one period to improve the data validity on filtered mode. With these changes in place, out of 100000 reads, a single one failed, ie 99.999% of the data was valid.

---

Changes in v2:
- Added macros for the wait and timeout times (and in the process made the wait 200us instead of 240us, just to simplify, gives the same result)
- Rebased on thermal/bleeding-edge (since the "thermal/drivers/mediatek/lvts_thermal: Fixes to the interrupt handling" series was merged)

 drivers/thermal/mediatek/lvts_thermal.c | 19 ++++++++++++-------
 1 file changed, 12 insertions(+), 7 deletions(-)
drivers/thermal/mediatek/lvts_thermal.c +12 -7
index ea89b29ffe5f..1a3cb118ff32 100644
@@ -58,11 +58,11 @@
 #define LVTS_PROTTC(__base)		(__base + 0x00CC)
 #define LVTS_CLKEN(__base)		(__base + 0x00E4)
 
-#define LVTS_PERIOD_UNIT			((118 * 1000) / (256 * 38))
-#define LVTS_GROUP_INTERVAL			1
-#define LVTS_FILTER_INTERVAL		1
-#define LVTS_SENSOR_INTERVAL		1
-#define LVTS_HW_FILTER				0x2
+#define LVTS_PERIOD_UNIT			0
+#define LVTS_GROUP_INTERVAL			0
+#define LVTS_FILTER_INTERVAL		0
+#define LVTS_SENSOR_INTERVAL		0
+#define LVTS_HW_FILTER				0x0
 #define LVTS_TSSEL_CONF				0x13121110
 #define LVTS_CALSCALE_CONF			0x300
 #define LVTS_MONINT_CONF			0x8300318C
@@ -86,6 +86,9 @@
 #define LVTS_MSR_IMMEDIATE_MODE		0
 #define LVTS_MSR_FILTERED_MODE		1
 
+#define LVTS_MSR_READ_TIMEOUT_US	400
+#define LVTS_MSR_READ_WAIT_US		(LVTS_MSR_READ_TIMEOUT_US / 2)
+
 #define LVTS_HW_SHUTDOWN_MT8195		105000
 
 #define LVTS_MINIMUM_THRESHOLD		20000
@@ -268,6 +271,7 @@ static int lvts_get_temp(struct thermal_zone_device *tz, int *temp)
 	struct lvts_sensor *lvts_sensor = thermal_zone_device_priv(tz);
 	void __iomem *msr = lvts_sensor->msr;
 	u32 value;
+	int rc;
 
 	/*
 	 * Measurement registers:
@@ -280,7 +284,8 @@ static int lvts_get_temp(struct thermal_zone_device *tz, int *temp)
 	 * 16	: Valid temperature
 	 * 15-0	: Raw temperature
 	 */
-	value = readl(msr);
+	rc = readl_poll_timeout(msr, value, value & BIT(16),
+				LVTS_MSR_READ_WAIT_US, LVTS_MSR_READ_TIMEOUT_US);
 
 	/*
 	 * As the thermal zone temperature will read before the
@@ -293,7 +298,7 @@ static int lvts_get_temp(struct thermal_zone_device *tz, int *temp)
 	 * functionning temperature and directly jump to a system
 	 * shutdown.
 	 */
-	if (!(value & BIT(16)))
+	if (rc)
 		return -EAGAIN;
 
 	*temp = lvts_raw_to_temp(value & 0xFFFF);
Signature · 1 line
2.41.0
maintainer Reviewed-by on v2 1/1
#1 lore raw

Il 13/07/23 17:42, Nícolas F. R. A. Prado ha scritto:

Quoted 18 lines

Currently, when a controller is configured to use filtered mode, thermal readings are valid only about 30% of the time.

Upon testing, it was noticed that lowering any of the interval settings resulted in an improved rate of valid data. The same was observed when decreasing the number of samples for each sensor (which also results in quicker measurements).

Retrying the read with a timeout longer than the time it takes to resample (about 344us with these settings and 4 sensors) also improves the rate.

Lower all timing settings to the minimum, configure the filtering to single sample, and poll the measurement register for at least one period to improve the data validity on filtered mode. With these changes in place, out of 100000 reads, a single one failed, ie 99.999% of the data was valid.

Quoted 4 lines

Good to go!

#2 lore raw
In reply to Nícolas F. R. A. Prado
Quoted 18 lines · Nícolas F. R. A. Prado

Currently, when a controller is configured to use filtered mode, thermal readings are valid only about 30% of the time.

Upon testing, it was noticed that lowering any of the interval settings resulted in an improved rate of valid data. The same was observed when decreasing the number of samples for each sensor (which also results in quicker measurements).

Retrying the read with a timeout longer than the time it takes to resample (about 344us with these settings and 4 sensors) also improves the rate.

Lower all timing settings to the minimum, configure the filtering to single sample, and poll the measurement register for at least one period to improve the data validity on filtered mode. With these changes in place, out of 100000 reads, a single one failed, ie 99.999% of the data was valid.

Quoted 3 lines

Hi Daniel,

gentle ping on this patch.

Thanks,
Nícolas

Reviewed-by on v2 1/1
#3 lore raw
In reply to Nícolas F. R. A. Prado
Quoted 17 lines · Nícolas F. R. A. Prado

Currently, when a controller is configured to use filtered mode, thermal readings are valid only about 30% of the time.

Upon testing, it was noticed that lowering any of the interval settings resulted in an improved rate of valid data. The same was observed when decreasing the number of samples for each sensor (which also results in quicker measurements).

Retrying the read with a timeout longer than the time it takes to resample (about 344us with these settings and 4 sensors) also improves the rate.

Lower all timing settings to the minimum, configure the filtering to single sample, and poll the measurement register for at least one period to improve the data validity on filtered mode. With these changes in place, out of 100000 reads, a single one failed, ie 99.999% of the data was valid.

Signature · 2 lines
Regards,
Alexandre
#4 lore raw
In reply to Nícolas F. R. A. Prado
Quoted 18 lines · Nícolas F. R. A. Prado

Currently, when a controller is configured to use filtered mode, thermal readings are valid only about 30% of the time.

Upon testing, it was noticed that lowering any of the interval settings resulted in an improved rate of valid data. The same was observed when decreasing the number of samples for each sensor (which also results in quicker measurements).

Retrying the read with a timeout longer than the time it takes to resample (about 344us with these settings and 4 sensors) also improves the rate.

Lower all timing settings to the minimum, configure the filtering to single sample, and poll the measurement register for at least one period to improve the data validity on filtered mode. With these changes in place, out of 100000 reads, a single one failed, ie 99.999% of the data was valid.

Quoted 5 lines

---

Applied, thanks

Signature · 5 lines
<http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs

Follow Linaro:  <http://www.facebook.com/pages/Linaro> Facebook |
<http://twitter.com/#!/linaroorg> Twitter |
<http://www.linaro.org/linaro-blog/> Blog