PATCH 1/1 ARM: dts: imx6ull-dhcor: Remove 900MHz operating point

Due to CPU lifetime consideration of the SoC manufacturer [1] and the preferred area of operation in the industrial related environment, set the maximum frequency for each DHCOM i.MX6ULL to 792MHz, as with the industrial type. This is done by removing the operating point at 900MHz and set the clock-frequency to 792000000.

[1] https://www.nxp.com/docs/en/application-note/AN5337.pdf

---
Cc: Rob Herring <[email protected]>
Cc: Krzysztof Kozlowski <[email protected]>
Cc: Conor Dooley <[email protected]>
Cc: Shawn Guo <[email protected]>
Cc: Marek Vasut <[email protected]>
Cc: Fabio Estevam <[email protected]>
Cc: NXP Linux Team <[email protected]>
Cc: [email protected]
Cc: [email protected]
Cc: [email protected]
To: [email protected]

---
 arch/arm/boot/dts/nxp/imx/imx6ull-dhcor-som.dtsi | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
arch/arm/boot/dts/nxp/imx/imx6ull-dhcor-som.dtsi +5 -2
index 45315adfaa86..75486e1b0c15 100644
@@ -28,10 +28,14 @@
 	/*
 	 * Due to the design as a solderable SOM, there are no capacitors
 	 * below the SoC, therefore higher voltages are required.
+	 * Due to CPU lifetime consideration of the SoC manufacturer and
+	 * the preferred area of operation in the industrial related
+	 * environment, set the maximum frequency for each DHCOM i.MX6ULL
+	 * to 792MHz, as with the industrial type.
 	 */
+	clock-frequency = <792000000>;
 	operating-points = <
 		/* kHz	uV */
-		900000	1275000
 		792000	1250000 /* Voltage increased */
 		528000	1175000
 		396000	1025000
@@ -39,7 +43,6 @@
 	>;
 	fsl,soc-operating-points = <
 		/* KHz	uV */
-		900000	1250000
 		792000	1250000 /* Voltage increased */
 		528000	1175000
 		396000	1175000
Signature · 1 line
2.11.0
Applied
#1 lore raw
Quoted 9 lines · Christoph Niedermaier

Due to CPU lifetime consideration of the SoC manufacturer [1] and the preferred area of operation in the industrial related environment, set the maximum frequency for each DHCOM i.MX6ULL to 792MHz, as with the industrial type. This is done by removing the operating point at 900MHz and set the clock-frequency to 792000000.

[1] https://www.nxp.com/docs/en/application-note/AN5337.pdf

Applied, thanks!