Skip to contentSkip to conversation

net/mlx5: fix sync meter action

PATCH Superseded Gregory Etelson 2 participants 3 messages Mar 18, 2024 – Mar 24, 2024 Network drivers

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 net/mlx5: fix sync meter action

PMD implements sync METER flow action as async.
Queue selected for sync operations is MLX5_HW_INV_QUEUE. That dummy queue value is translated into CTRL_QUEUE_ID(priv). Async job allocation converts INV queue into the real value, but job release does not.

This patch fixes the queue value provided to flow_hw_job_put().

This patch also removes dead code found in METER_MARK destroy handler.

Coverity issue: tag: 415806: Memory - corruptions (OVERRUN) Coverity issue: tag: 415804: Control flow issues (DEADCODE)

Fixes 4359d9d1f76b ("net/mlx5: fix sync meter processing in HWS")
---
 drivers/net/mlx5/mlx5_flow_hw.c    | 5 +----
 drivers/net/mlx5/mlx5_flow_meter.c | 2 +-
 2 files changed, 2 insertions(+), 5 deletions(-)
drivers/net/mlx5/mlx5_flow_hw.c +1 -4
index 35f1ed7a03..9ebbe664d1 100644
@@ -11494,10 +11494,7 @@ flow_hw_action_handle_destroy(struct rte_eth_dev *dev, uint32_t queue,
 				NULL, "Unable to wait for ASO meter CQE");
 			break;
 		}
-		if (!job)
-			mlx5_ipool_free(pool->idx_pool, idx);
-		else
-			aso = true;
+		aso = true;
 		break;
 	case MLX5_INDIRECT_ACTION_TYPE_RSS:
 		ret = flow_dv_action_destroy(dev, handle, error);
drivers/net/mlx5/mlx5_flow_meter.c +1 -1
index 4045c4c249..ca361f7efa 100644
@@ -2265,7 +2265,7 @@ mlx5_flow_meter_hws_create(struct rte_eth_dev *dev, uint32_t meter_id,
 	ret = mlx5_aso_meter_update_by_wqe(priv, MLX5_HW_INV_QUEUE, aso_mtr,
 					   &priv->mtr_bulk, job, true);
 	if (ret) {
-		flow_hw_job_put(priv, job, MLX5_HW_INV_QUEUE);
+		flow_hw_job_put(priv, job, CTRL_QUEUE_ID(priv));
 		return -rte_mtr_error_set(error, ENOTSUP,
 					  RTE_MTR_ERROR_TYPE_UNSPECIFIED,
 					  NULL, "Failed to create devx meter.");
Signature · 1 line
2.39.2
#1 lore raw

PATCH v2 1/1 net/mlx5: fix sync meter action

PMD implements sync METER flow action as async.
Queue selected for sync operations is MLX5_HW_INV_QUEUE. That dummy queue value is translated into CTRL_QUEUE_ID(priv). Async job allocation converts INV queue into the real value, but job release does not.

This patch fixes the queue value provided to flow_hw_job_put().

This patch also removes dead code found in METER_MARK destroy handler.

Coverity issue: 415806
Coverity issue: 415804

Fixes 4359d9d1f76b ("net/mlx5: fix sync meter processing in HWS")

---
v2: Fixed Coverity tag.

---
 drivers/net/mlx5/mlx5_flow_hw.c    | 5 +----
 drivers/net/mlx5/mlx5_flow_meter.c | 2 +-
 2 files changed, 2 insertions(+), 5 deletions(-)
drivers/net/mlx5/mlx5_flow_hw.c +1 -4
index 35f1ed7a03..9ebbe664d1 100644
@@ -11494,10 +11494,7 @@ flow_hw_action_handle_destroy(struct rte_eth_dev *dev, uint32_t queue,
 				NULL, "Unable to wait for ASO meter CQE");
 			break;
 		}
-		if (!job)
-			mlx5_ipool_free(pool->idx_pool, idx);
-		else
-			aso = true;
+		aso = true;
 		break;
 	case MLX5_INDIRECT_ACTION_TYPE_RSS:
 		ret = flow_dv_action_destroy(dev, handle, error);
drivers/net/mlx5/mlx5_flow_meter.c +1 -1
index 4045c4c249..ca361f7efa 100644
@@ -2265,7 +2265,7 @@ mlx5_flow_meter_hws_create(struct rte_eth_dev *dev, uint32_t meter_id,
 	ret = mlx5_aso_meter_update_by_wqe(priv, MLX5_HW_INV_QUEUE, aso_mtr,
 					   &priv->mtr_bulk, job, true);
 	if (ret) {
-		flow_hw_job_put(priv, job, MLX5_HW_INV_QUEUE);
+		flow_hw_job_put(priv, job, CTRL_QUEUE_ID(priv));
 		return -rte_mtr_error_set(error, ENOTSUP,
 					  RTE_MTR_ERROR_TYPE_UNSPECIFIED,
 					  NULL, "Failed to create devx meter.");
Signature · 1 line
2.39.2
#2 lore raw

19/03/2024 12:24, Gregory Etelson:

Quoted 11 lines

PMD implements sync METER flow action as async.
Queue selected for sync operations is MLX5_HW_INV_QUEUE. That dummy queue value is translated into CTRL_QUEUE_ID(priv). Async job allocation converts INV queue into the real value, but job release does not.

This patch fixes the queue value provided to flow_hw_job_put().

This patch also removes dead code found in METER_MARK destroy handler.

Quoted 7 lines

Coverity issue: 415806
Coverity issue: 415804

Fixes 4359d9d1f76b ("net/mlx5: fix sync meter processing in HWS")

Applied, thanks.