iio: health: max30102: add support for max30101
Subsystems (2)
v2 cover iio: health: max30102: add support for max30101
The Maxim max30101 is the replacement for the max30105, which is no longer recommended for new designs [1].
The max30101 is described as a pulse oximeter and heart-rate sensor, as opposed to the max30105, which is described as an optical sensor for smoke detection applications. In the end, the internal structure is identical, as well as the register map, voltages and sensitivity. Only the pinout has changed, which is not relevant for the driver.
A new compatible has been added, but the logic used for the max30105 can be re-used for the new part.
---
Changes in v2:
- dt-bindings: use maxim,max30105 as the fallback compatible for maxim,max30101.
- PATCH 1/2: Typo in commit description.
- Link to v1: https://lore.kernel.org/r/[email protected]
---
Javier Carrasco (2):
dt-bindings: iio: health: maxim,max30102: add max30101
iio: health: max30102: add support for max30101.../devicetree/bindings/iio/health/maxim,max30102.yaml | 12 ++++++++---- drivers/iio/health/max30102.c | 2 ++ 2 files changed, 10 insertions(+), 4 deletions(-)
---
base-commit: 70293240c5ce675a67bfc48f419b093023b862b3
change-id: 20240317-max30101-edbe658b6633
Best regards,
Signature · 1 line
Javier Carrasco <[email protected]>
PATCH v2 1/2 dt-bindings: iio: health: maxim,max30102: add max30101
The Maxim max30101 is the replacement for the max30105, which is no longer recommended for future designs.
The max30101 does not require new properties, and it can be described with the existing ones for the max30105, which will be used as a fallback compatible.
--- .../devicetree/bindings/iio/health/maxim,max30102.yaml | 12 ++++++++---- 1 file changed, 8 insertions(+), 4 deletions(-)
Documentation/devicetree/bindings/iio/health/maxim,max30102.yaml +8 -4
@@ -4,16 +4,20 @@ $id: http://devicetree.org/schemas/iio/health/maxim,max30102.yaml# $schema: http://devicetree.org/meta-schemas/core.yaml# -title: Maxim MAX30102 heart rate and pulse oximeter and MAX30105 particle-sensor +title: Maxim MAX30101/2 heart rate and pulse oximeter and MAX30105 particle-sensor maintainers: - Matt Ranostay <[email protected]> properties: compatible: - enum: - - maxim,max30102 - - maxim,max30105 + oneOf: + - enum: + - maxim,max30102 + - maxim,max30105 + - items: + - const: maxim,max30101 + - const: maxim,max30105 reg: maxItems: 1
Signature · 1 line
2.40.1
Re: [PATCH v2 1/2] dt-bindings: iio: health: maxim,max30102: add max30101
Quoted 11 lines · Javier Carrasco
The Maxim max30101 is the replacement for the max30105, which is no longer recommended for future designs.
The max30101 does not require new properties, and it can be described with the existing ones for the max30105, which will be used as a fallback compatible.
Signed-off-by Javier Carrasco <[email protected]>--- .../devicetree/bindings/iio/health/maxim,max30102.yaml | 12 ++++++++---- 1 file changed, 8 insertions(+), 4 deletions(-)
Best regards,
Krzysztof
Jonathan Cameron
maintainerRe: [PATCH v2 1/2] dt-bindings: iio: health: maxim,max30102: add max30101
Quoted 13 lines · On Mon, 25 Mar 2024 13:18:14 +0100 Krzysztof Kozlowski…
Quoted 11 lines · Javier Carrasco
The Maxim max30101 is the replacement for the max30105, which is no longer recommended for future designs.
The max30101 does not require new properties, and it can be described with the existing ones for the max30105, which will be used as a fallback compatible.
Signed-off-by Javier Carrasco <[email protected]>--- .../devicetree/bindings/iio/health/maxim,max30102.yaml | 12 ++++++++---- 1 file changed, 8 insertions(+), 4 deletions(-)
Quoted 6 lines
Reviewed-by Krzysztof Kozlowski <[email protected]>Best regards,
Krzysztof
Thanks,
Series applied to the togreg branch of iio.git and initially pushed out as testing to get it some build testing from 0-day.
Thanks,
Jonathan
PATCH v2 2/2 iio: health: max30102: add support for max30101
In reply to Javier CarrascoThe Maxim max30101 is the replacement for the max30105, which is no longer recommended for future designs.
Their internal structure is identical, as well as the register map, configuration options and sensitivity, which allows for code recycling.
--- drivers/iio/health/max30102.c | 2 ++ 1 file changed, 2 insertions(+)
drivers/iio/health/max30102.c +2 -0
@@ -613,6 +613,7 @@ static void max30102_remove(struct i2c_client *client) }static const struct i2c_device_id max30102_id[] = { + {"max30101" , max30105 }, {"max30102" , max30102 }, {"max30105" , max30105 }, {}
@@ -620,6 +621,7 @@ static const struct i2c_device_id max30102_id[] = {MODULE_DEVICE_TABLE (i2c, max30102_id);static const struct of_device_id max30102_dt_ids[] = { + { .compatible ="maxim,max30101" }, { .compatible ="maxim,max30102" }, { .compatible ="maxim,max30105" }, { }
Signature · 1 line
2.40.1