nvmet: fix nvme status code when namespace is disabled

PATCH In review Sagi Grimberg 6 participants 7 messages Apr 28, 2024 – May 23, 2024

Subsystems (2)
lore
Share & tools
lore

Sagi Grimberg

author maintainer
#0 lore raw

PATCH 1/1 nvmet: fix nvme status code when namespace is disabled

If the user disabled a nvmet namesapce, it is removed from the subsystem namespaces list. When nvmet processes a command directed to an nsid that was disabled, it cannot differentiate between a nsid that is disabled vs. a non-existent namespace, and resorts to return NVME_SC_INVALID_NS with the dnr bit set.

This translates to a non-retryable status for the host, which translates to a user error. We should expect disabled namespaces to not cause an I/O error in a multipath environment.

Address this by searching a configfs item for the namespace nvmet failed to find, and if we found one, conclude that the namespace is disabled (perhaps temporarily). Return NVME_SC_INTERNAL_PATH_ERROR in this case and keep DNR bit cleared.

---
Jirong Feng, can you please re-run the test as requested and verify that the I/O error goes away. If so, please reply with your "Tested-by" tag.

 drivers/nvme/target/configfs.c | 13 +++++++++++++
 drivers/nvme/target/core.c     |  8 ++++++--
 drivers/nvme/target/nvmet.h    |  1 +
 3 files changed, 20 insertions(+), 2 deletions(-)
drivers/nvme/target/configfs.c +13 -0
index 77a6e817b315..e744bd0a9cc2 100644
@@ -754,6 +754,19 @@ static struct configfs_attribute *nvmet_ns_attrs[] = {
 	NULL,
 };
 
+bool nvmet_subsys_nsid_exists(struct nvmet_subsys *subsys, u32 nsid)
+{
+	struct config_item *ns_item;
+	char name[4] = {};
+
+	if (sprintf(name, "%u", nsid) <= 0)
+		return false;
+	mutex_lock(&subsys->namespaces_group.cg_subsys->su_mutex);
+	ns_item = config_group_find_item(&subsys->namespaces_group, name);
+	mutex_unlock(&subsys->namespaces_group.cg_subsys->su_mutex);
+	return ns_item != NULL;
+}
+
 static void nvmet_ns_release(struct config_item *item)
 {
 	struct nvmet_ns *ns = to_nvmet_ns(item);
drivers/nvme/target/core.c +6 -2
index 78cba026610a..ed0b8f3707b4 100644
@@ -437,11 +437,15 @@ void nvmet_stop_keep_alive_timer(struct nvmet_ctrl *ctrl)
 u16 nvmet_req_find_ns(struct nvmet_req *req)
 {
 	u32 nsid = le32_to_cpu(req->cmd->common.nsid);
+	struct nvmet_subsys *subsys = nvmet_req_subsys(req);
 
-	req->ns = xa_load(&nvmet_req_subsys(req)->namespaces, nsid);
+	req->ns = xa_load(&subsys->namespaces, nsid);
 	if (unlikely(!req->ns)) {
 		req->error_loc = offsetof(struct nvme_common_command, nsid);
-		return NVME_SC_INVALID_NS | NVME_SC_DNR;
+		if (nvmet_subsys_nsid_exists(subsys, nsid))
+			return NVME_SC_INTERNAL_PATH_ERROR;
+		else
+			return NVME_SC_INVALID_NS | NVME_SC_DNR;
 	}
 
 	percpu_ref_get(&req->ns->ref);
drivers/nvme/target/nvmet.h +1 -0
index f460728e1df1..c1306de1f4dd 100644
@@ -543,6 +543,7 @@ void nvmet_subsys_disc_changed(struct nvmet_subsys *subsys,
 		struct nvmet_host *host);
 void nvmet_add_async_event(struct nvmet_ctrl *ctrl, u8 event_type,
 		u8 event_info, u8 log_page);
+bool nvmet_subsys_nsid_exists(struct nvmet_subsys *subsys, u32 nsid);
 
 #define NVMET_MIN_QUEUE_SIZE	16
 #define NVMET_MAX_QUEUE_SIZE	1024
Signature · 1 line
2.40.1
maintainer Reviewed-by on v1 1/1
#1 lore raw
Quoted 1 line · Sagi Grimberg

If the user disabled a nvmet namesapce, it is removed from

s/namesapce/namespace/

(lines also look a little short here, maybe use up all 73 chars when refreshing it).

drivers/nvme/target/core.c void nvmet_stop_keep_alive_timer(struct nvmet_ctrl *ctrl) · line 448

Quoted 4 lines
drivers/nvme/target/core.c +4 -0
+		if (nvmet_subsys_nsid_exists(subsys, nsid))
+			return NVME_SC_INTERNAL_PATH_ERROR;
+		else
+			return NVME_SC_INVALID_NS | NVME_SC_DNR;

No need for an else after a return.

Otherwise looks good:

maintainer
#3 lore raw
In reply to Sagi Grimberg
Quoted 10 lines · Sagi Grimberg

If the user disabled a nvmet namesapce, it is removed from the subsystem namespaces list. When nvmet processes a command directed to an nsid that was disabled, it cannot differentiate between a nsid that is disabled vs. a non-existent namespace, and resorts to return NVME_SC_INVALID_NS with the dnr bit set.

This translates to a non-retryable status for the host, which translates to a user error. We should expect disabled namespaces to not cause an I/O error in a multipath environment.

Quoted 7 lines

Address this by searching a configfs item for the namespace nvmet failed to find, and if we found one, conclude that the namespace is disabled (perhaps temporarily). Return NVME_SC_INTERNAL_PATH_ERROR in this case and keep DNR bit cleared.

Applied with Jirong's "Tested-by" and Christoph's suggestions (spelling, word wrap, and unnecessary 'else') to nvme-6.9.

Reviewed-by on v1 1/1
#4 lore raw
In reply to Sagi Grimberg
Quoted 15 lines · Sagi Grimberg

If the user disabled a nvmet namesapce, it is removed from the subsystem namespaces list. When nvmet processes a command directed to an nsid that was disabled, it cannot differentiate between a nsid that is disabled vs. a non-existent namespace, and resorts to return NVME_SC_INVALID_NS with the dnr bit set.

This translates to a non-retryable status for the host, which translates to a user error. We should expect disabled namespaces to not cause an I/O error in a multipath environment.

Address this by searching a configfs item for the namespace nvmet failed to find, and if we found one, conclude that the namespace is disabled (perhaps temporarily). Return NVME_SC_INTERNAL_PATH_ERROR in this case and keep DNR bit cleared.

Quoted 7 lines

---
Jirong Feng, can you please re-run the test as requested and verify that the I/O error goes away. If so, please reply with your "Tested-by" tag.

FWIW,

-ck

#5 lore raw
In reply to Sagi Grimberg
Quoted 78 lines · Sagi Grimberg

If the user disabled a nvmet namesapce, it is removed from the subsystem namespaces list. When nvmet processes a command directed to an nsid that was disabled, it cannot differentiate between a nsid that is disabled vs. a non-existent namespace, and resorts to return NVME_SC_INVALID_NS with the dnr bit set.

This translates to a non-retryable status for the host, which translates to a user error. We should expect disabled namespaces to not cause an I/O error in a multipath environment.

Address this by searching a configfs item for the namespace nvmet failed to find, and if we found one, conclude that the namespace is disabled (perhaps temporarily). Return NVME_SC_INTERNAL_PATH_ERROR in this case and keep DNR bit cleared.

---
Jirong Feng, can you please re-run the test as requested and verify that the I/O error goes away. If so, please reply with your "Tested-by" tag.

  drivers/nvme/target/configfs.c | 13 +++++++++++++
  drivers/nvme/target/core.c     |  8 ++++++--
  drivers/nvme/target/nvmet.h    |  1 +
  3 files changed, 20 insertions(+), 2 deletions(-)
drivers/nvme/target/configfs.c +13 -0
index 77a6e817b315..e744bd0a9cc2 100644
@@ -754,6 +754,19 @@ static struct configfs_attribute *nvmet_ns_attrs[] = {
  	NULL,
  };
 
+bool nvmet_subsys_nsid_exists(struct nvmet_subsys *subsys, u32 nsid)
+{
+	struct config_item *ns_item;
+	char name[4] = {};
+
+	if (sprintf(name, "%u", nsid) <= 0)
+		return false;
+	mutex_lock(&subsys->namespaces_group.cg_subsys->su_mutex);
+	ns_item = config_group_find_item(&subsys->namespaces_group, name);
+	mutex_unlock(&subsys->namespaces_group.cg_subsys->su_mutex);
+	return ns_item != NULL;
+}
+
  static void nvmet_ns_release(struct config_item *item)
  {
  	struct nvmet_ns *ns = to_nvmet_ns(item);
drivers/nvme/target/core.c +6 -2
index 78cba026610a..ed0b8f3707b4 100644
@@ -437,11 +437,15 @@ void nvmet_stop_keep_alive_timer(struct nvmet_ctrl *ctrl)
  u16 nvmet_req_find_ns(struct nvmet_req *req)
  {
  	u32 nsid = le32_to_cpu(req->cmd->common.nsid);
+	struct nvmet_subsys *subsys = nvmet_req_subsys(req);
 
-	req->ns = xa_load(&nvmet_req_subsys(req)->namespaces, nsid);
+	req->ns = xa_load(&subsys->namespaces, nsid);
  	if (unlikely(!req->ns)) {
  		req->error_loc = offsetof(struct nvme_common_command, nsid);
-		return NVME_SC_INVALID_NS | NVME_SC_DNR;
+		if (nvmet_subsys_nsid_exists(subsys, nsid))
+			return NVME_SC_INTERNAL_PATH_ERROR;
+		else
+			return NVME_SC_INVALID_NS | NVME_SC_DNR;
  	}
 
  	percpu_ref_get(&req->ns->ref);
drivers/nvme/target/nvmet.h +0 -0
index f460728e1df1..c1306de1f4dd 100644

drivers/nvme/target/nvmet.h void nvmet_subsys_disc_changed(struct nvmet_subsys *subsys, · line 549

Quoted 7 lines
drivers/nvme/target/nvmet.h +1 -0
@@ -543,6 +543,7 @@ void nvmet_subsys_disc_changed(struct nvmet_subsys *subsys,
  		struct nvmet_host *host);
  void nvmet_add_async_event(struct nvmet_ctrl *ctrl, u8 event_type,
  		u8 event_info, u8 log_page);
+bool nvmet_subsys_nsid_exists(struct nvmet_subsys *subsys, u32 nsid);
 
  #define NVMET_MIN_QUEUE_SIZE	16
  #define NVMET_MAX_QUEUE_SIZE	1024

Shouldn't we rather use 'ANA inaccessible' status here?
Just to make it clear that the namespace is disabled, and not some other internal error?

Cheers,

Hannes

author maintainer
#6 lore raw
Quoted 80 lines · Hannes Reinecke
Quoted 79 lines · Sagi Grimberg

If the user disabled a nvmet namesapce, it is removed from the subsystem namespaces list. When nvmet processes a command directed to an nsid that was disabled, it cannot differentiate between a nsid that is disabled vs. a non-existent namespace, and resorts to return NVME_SC_INVALID_NS with the dnr bit set.

This translates to a non-retryable status for the host, which translates to a user error. We should expect disabled namespaces to not cause an I/O error in a multipath environment.

Address this by searching a configfs item for the namespace nvmet failed to find, and if we found one, conclude that the namespace is disabled (perhaps temporarily). Return NVME_SC_INTERNAL_PATH_ERROR in this case and keep DNR bit cleared.

---
Jirong Feng, can you please re-run the test as requested and verify that the I/O error goes away. If so, please reply with your "Tested-by" tag.

  drivers/nvme/target/configfs.c | 13 +++++++++++++ drivers/nvme/target/core.c     |  8 ++++++-- drivers/nvme/target/nvmet.h    |  1 +

  3 files changed, 20 insertions(+), 2 deletions(-)
drivers/nvme/target/configfs.c +12 -0
index 77a6e817b315..e744bd0a9cc2 100644
@@ -754,6 +754,19 @@ static struct configfs_attribute 
 *nvmet_ns_attrs[] = {
       NULL,
   };
   +bool nvmet_subsys_nsid_exists(struct nvmet_subsys *subsys, u32 nsid)
+{
+    struct config_item *ns_item;
+    char name[4] = {};
+
+    if (sprintf(name, "%u", nsid) <= 0)
+        return false;
+ mutex_lock(&subsys->namespaces_group.cg_subsys->su_mutex);
+    ns_item = config_group_find_item(&subsys->namespaces_group, name);
+ mutex_unlock(&subsys->namespaces_group.cg_subsys->su_mutex);
+    return ns_item != NULL;
+}
+
   static void nvmet_ns_release(struct config_item *item)
   {

      struct nvmet_ns *ns = to_nvmet_ns(item);

drivers/nvme/target/core.c +6 -1
index 78cba026610a..ed0b8f3707b4 100644
@@ -437,11 +437,15 @@ void nvmet_stop_keep_alive_timer(struct 
 nvmet_ctrl *ctrl)
   u16 nvmet_req_find_ns(struct nvmet_req *req)
   {
       u32 nsid = le32_to_cpu(req->cmd->common.nsid);
+    struct nvmet_subsys *subsys = nvmet_req_subsys(req);
   -    req->ns = xa_load(&nvmet_req_subsys(req)->namespaces, nsid);
+    req->ns = xa_load(&subsys->namespaces, nsid);
       if (unlikely(!req->ns)) {
           req->error_loc = offsetof(struct nvme_common_command, nsid);
-        return NVME_SC_INVALID_NS | NVME_SC_DNR;
+        if (nvmet_subsys_nsid_exists(subsys, nsid))
+            return NVME_SC_INTERNAL_PATH_ERROR;
+        else
+            return NVME_SC_INVALID_NS | NVME_SC_DNR;
       }
         percpu_ref_get(&req->ns->ref);
drivers/nvme/target/nvmet.h +0 -0
index f460728e1df1..c1306de1f4dd 100644
@@ -543,6 +543,7 @@ void nvmet_subsys_disc_changed(struct 
 nvmet_subsys *subsys,
           struct nvmet_host *host);
Quoted 8 lines

drivers/nvme/target/nvmet.h void nvmet_subsys_disc_changed(struct nvmet_subsys *subsys, · line 549

Quoted 5 lines
drivers/nvme/target/nvmet.h +1 -0
   void nvmet_add_async_event(struct nvmet_ctrl *ctrl, u8 event_type,
           u8 event_info, u8 log_page);
+bool nvmet_subsys_nsid_exists(struct nvmet_subsys *subsys, u32 nsid);
     #define NVMET_MIN_QUEUE_SIZE    16
   #define NVMET_MAX_QUEUE_SIZE    1024

Shouldn't we rather use 'ANA inaccessible' status here?
Just to make it clear that the namespace is disabled, and not some other internal error?

No, because this is not related to the ANA group, but a namespace error.