Add board support for Sipeed LicheeRV Nano
Subsystems (6)
v2 cover Add board support for Sipeed LicheeRV Nano
The LicheeRV Nano is a RISC-V SBC based on the Sophgo SG2002 chip. Adds minimal device tree files for this board to make it boot to a basic shell.
---
Changes in v2:
- Add SDHCI support
- Change device tree name to match the Makefile
- Add oscillator frequency
- Add aliases to other UARTs
- Add aliases to GPIOs
- Move compatible for SDHCI from common DT to specific DT
- Link to v1: https://lore.kernel.org/r/[email protected]
---
Thomas Bonnefille (6):
riscv: dts: sophgo: Put sdhci compatible in dt of specific SoC
dt-bindings: interrupt-controller: Add SOPHGO SG2002 plic
dt-bindings: timer: Add SOPHGO SG2002 clint
dt-bindings: riscv: Add Sipeed LicheeRV Nano board compatibles
riscv: dts: sophgo: Add initial SG2002 SoC device tree
riscv: dts: sophgo: Add LicheeRV Nano board device tree
.../interrupt-controller/sifive,plic-1.0.0.yaml | 1 + .../devicetree/bindings/riscv/sophgo.yaml | 5 ++ .../devicetree/bindings/timer/sifive,clint.yaml | 1 + arch/riscv/boot/dts/sophgo/Makefile | 1 + arch/riscv/boot/dts/sophgo/cv1800b.dtsi | 4 ++ arch/riscv/boot/dts/sophgo/cv18xx.dtsi | 1 - .../boot/dts/sophgo/sg2002-licheerv-nano-b.dts | 53 ++++++++++++++++++++++ arch/riscv/boot/dts/sophgo/sg2002.dtsi | 34 ++++++++++++++ 8 files changed, 99 insertions(+), 1 deletion(-)
---
base-commit: 83a7eefedc9b56fe7bfeff13b6c7356688ffa670
change-id: 20240515-sg2002-93dce1d263be
Best regards,
Signature · 1 line
Thomas Bonnefille <[email protected]>
PATCH v2 1/6 riscv: dts: sophgo: Put sdhci compatible in dt of specific SoC
Remove SDHCI compatible for CV1800b from common dtsi file to put it in the specific dtsi file of the CV1800b.
This commits aims at following the same guidelines as in the other nodes of the CV18XX family.
--- arch/riscv/boot/dts/sophgo/cv1800b.dtsi | 4 ++++ arch/riscv/boot/dts/sophgo/cv18xx.dtsi | 1 - 2 files changed, 4 insertions(+), 1 deletion(-)
arch/riscv/boot/dts/sophgo/cv1800b.dtsi +4 -0
@@ -25,3 +25,7 @@ &clint { &clk { compatible = "sophgo,cv1800-clk"; }; + +&sdhci0 { + compatible = "sophgo,cv1800b-dwcmshc"; +};
arch/riscv/boot/dts/sophgo/cv18xx.dtsi +0 -1
@@ -288,7 +288,6 @@ uart4: serial@41c0000 { }; sdhci0: mmc@4310000 { - compatible = "sophgo,cv1800b-dwcmshc"; reg = <0x4310000 0x1000>; interrupts = <36 IRQ_TYPE_LEVEL_HIGH>; clocks = <&clk CLK_AXI4_SD0>,
Signature · 1 line
2.45.2
Re: [PATCH v2 1/6] riscv: dts: sophgo: Put sdhci compatible in dt of specific SoC
Quoted 39 lines · Thomas Bonnefille
Remove SDHCI compatible for CV1800b from common dtsi file to put it in the specific dtsi file of the CV1800b.
This commits aims at following the same guidelines as in the other nodes of the CV18XX family.Signed-off-by Thomas Bonnefille <[email protected]>--- arch/riscv/boot/dts/sophgo/cv1800b.dtsi | 4 ++++ arch/riscv/boot/dts/sophgo/cv18xx.dtsi | 1 - 2 files changed, 4 insertions(+), 1 deletion(-)arch/riscv/boot/dts/sophgo/cv1800b.dtsi +4
-0@@ -25,3 +25,7 @@ &clint { &clk { compatible = "sophgo,cv1800-clk"; }; + +&sdhci0 { + compatible = "sophgo,cv1800b-dwcmshc"; +};arch/riscv/boot/dts/sophgo/cv18xx.dtsi +0
-1@@ -288,7 +288,6 @@ uart4: serial@41c0000 { }; sdhci0: mmc@4310000 { - compatible = "sophgo,cv1800b-dwcmshc"; reg = <0x4310000 0x1000>; interrupts = <36 IRQ_TYPE_LEVEL_HIGH>; clocks = <&clk CLK_AXI4_SD0>,Signature · 2 lines
-- 2.45.2
Hi, Jisheng,
Is this change necessary? IIRC, the sdhci is the same across the whole series.
Regards,
Inochi
Re: [PATCH v2 1/6] riscv: dts: sophgo: Put sdhci compatible in dt of specific SoC
Hi
Quoted 5 lines · Inochi Amaoto
Quoted 4 lines · Thomas Bonnefille
Remove SDHCI compatible for CV1800b from common dtsi file to put it in the specific dtsi file of the CV1800b.
This commits aims at following the same guidelines as in the other nodes of the CV18XX family.
is there any URL of guideline? or did I miss anything couldn't find any discussion about this in v1
Quoted 32 lines
Quoted 32 lines
Signed-off-by Thomas Bonnefille <[email protected]>--- arch/riscv/boot/dts/sophgo/cv1800b.dtsi | 4 ++++ arch/riscv/boot/dts/sophgo/cv18xx.dtsi | 1 - 2 files changed, 4 insertions(+), 1 deletion(-)arch/riscv/boot/dts/sophgo/cv1800b.dtsi +4
-0@@ -25,3 +25,7 @@ &clint { &clk { compatible = "sophgo,cv1800-clk"; }; + +&sdhci0 { + compatible = "sophgo,cv1800b-dwcmshc"; +};arch/riscv/boot/dts/sophgo/cv18xx.dtsi +0
-1@@ -288,7 +288,6 @@ uart4: serial@41c0000 { }; sdhci0: mmc@4310000 { - compatible = "sophgo,cv1800b-dwcmshc"; reg = <0x4310000 0x1000>; interrupts = <36 IRQ_TYPE_LEVEL_HIGH>; clocks = <&clk CLK_AXI4_SD0>,
Quoted 8 lines
Quoted 3 lines
Signature · 1 line
2.45.2Hi, Jisheng,
Is this change necessary? IIRC, the sdhci is the same across the whole series.
I tend to agree with Inochi here, if it's same across all SoC, then no bother to split, it will cause more trouble to maintain..
Quoted 3 lines
Regards,
Inochi
Signature · 3 lines
Yixun Lan (dlan) Gentoo Linux Developer GPG Key ID AABEFD55
Re: [PATCH v2 1/6] riscv: dts: sophgo: Put sdhci compatible in dt of specific SoC
Quoted 11 lines · Yixun Lan
Hi
Quoted 5 lines · Inochi Amaoto
Quoted 4 lines · Thomas Bonnefille
Remove SDHCI compatible for CV1800b from common dtsi file to put it in the specific dtsi file of the CV1800b.
This commits aims at following the same guidelines as in the other nodes of the CV18XX family.is there any URL of guideline? or did I miss anything couldn't find any discussion about this in v1
No, it seems like that this is a new change from Thomas.
Quoted 51 lines
Quoted 32 lines
Quoted 32 lines
Signed-off-by Thomas Bonnefille <[email protected]>--- arch/riscv/boot/dts/sophgo/cv1800b.dtsi | 4 ++++ arch/riscv/boot/dts/sophgo/cv18xx.dtsi | 1 - 2 files changed, 4 insertions(+), 1 deletion(-)arch/riscv/boot/dts/sophgo/cv1800b.dtsi +4
-0@@ -25,3 +25,7 @@ &clint { &clk { compatible = "sophgo,cv1800-clk"; }; + +&sdhci0 { + compatible = "sophgo,cv1800b-dwcmshc"; +};arch/riscv/boot/dts/sophgo/cv18xx.dtsi +0
-1@@ -288,7 +288,6 @@ uart4: serial@41c0000 { }; sdhci0: mmc@4310000 { - compatible = "sophgo,cv1800b-dwcmshc"; reg = <0x4310000 0x1000>; interrupts = <36 IRQ_TYPE_LEVEL_HIGH>; clocks = <&clk CLK_AXI4_SD0>,Quoted 8 lines
Quoted 3 lines
Signature · 1 line
2.45.2Hi, Jisheng,
Is this change necessary? IIRC, the sdhci is the same across the whole series.
I tend to agree with Inochi here, if it's same across all SoC, then no bother to split, it will cause more trouble to maintain..
Quoted 3 lines
Regards,
InochiSignature · 3 lines
Yixun Lan (dlan) Gentoo Linux Developer GPG Key ID AABEFD55
Re: [PATCH v2 1/6] riscv: dts: sophgo: Put sdhci compatible in dt of specific SoC
In reply to Yixun LanQuoted 11 lines · Yixun Lan
Hi
Quoted 5 lines · Inochi Amaoto
Quoted 4 lines · Thomas Bonnefille
Remove SDHCI compatible for CV1800b from common dtsi file to put it in the specific dtsi file of the CV1800b.
This commits aims at following the same guidelines as in the other nodes of the CV18XX family.is there any URL of guideline? or did I miss anything couldn't find any discussion about this in v1
Not explicitly, the fact is that I had to use a specific compatible on SG2002 for the sdhci (it is already defined mainline), I had to choose between :
1. cv18xx.dtsi : compatible cv1800b-dwcmshc
cv1800b.dtsi : no redefined compatible
sg2002.dtsi : overwrite the previous compatible to use sg2002-dwcmshc
2. cv18xx.dtsi : no compatible
cv1800b.dtsi : compatible for cv1800b-dwcmshc
sg2002.dtsi : compatible for sg2002-dwcmshc
As in the plic and clint controllers, the second option was chosen I consider this as a "guideline" and reformat the dtsis accordingly.
Quoted 38 lines
Quoted 38 lines
Quoted 35 lines
Signed-off-by Thomas Bonnefille <[email protected]>--- arch/riscv/boot/dts/sophgo/cv1800b.dtsi | 4 ++++ arch/riscv/boot/dts/sophgo/cv18xx.dtsi | 1 - 2 files changed, 4 insertions(+), 1 deletion(-)arch/riscv/boot/dts/sophgo/cv1800b.dtsi +4
-0@@ -25,3 +25,7 @@ &clint { &clk { compatible = "sophgo,cv1800-clk"; }; + +&sdhci0 { + compatible = "sophgo,cv1800b-dwcmshc"; +};arch/riscv/boot/dts/sophgo/cv18xx.dtsi +0
-1@@ -288,7 +288,6 @@ uart4: serial@41c0000 { }; sdhci0: mmc@4310000 { - compatible = "sophgo,cv1800b-dwcmshc"; reg = <0x4310000 0x1000>; interrupts = <36 IRQ_TYPE_LEVEL_HIGH>; clocks = <&clk CLK_AXI4_SD0>,Signature · 2 lines
-- 2.45.2Hi, Jisheng,
Quoted 5 lines
Quoted 2 lines
Is this change necessary? IIRC, the sdhci is the same across the whole series.
I tend to agree with Inochi here, if it's same across all SoC, then no bother to split, it will cause more trouble to maintain..
To be honest, I agree with this to, but as a specific compatible for the SG2002 was created in commit 849e81817b9b, I thought that the best practice was to use it.
Quoted 4 lines
Quoted 3 lines
Regards,
Inochi
Re: [PATCH v2 1/6] riscv: dts: sophgo: Put sdhci compatible in dt of specific SoC
Quoted 23 lines · Thomas Bonnefille
Quoted 11 lines · Yixun Lan
Hi
Quoted 5 lines · Inochi Amaoto
Quoted 4 lines · Thomas Bonnefille
Remove SDHCI compatible for CV1800b from common dtsi file to put it in the specific dtsi file of the CV1800b.
This commits aims at following the same guidelines as in the other nodes of the CV18XX family.is there any URL of guideline? or did I miss anything couldn't find any discussion about this in v1
Not explicitly, the fact is that I had to use a specific compatible on SG2002 for the sdhci (it is already defined mainline), I had to choose between :
1.
cv18xx.dtsi: compatible cv1800b-dwcmshc
cv1800b.dtsi: no redefined compatible
sg2002.dtsi: overwrite the previous compatible to use sg2002-dwcmshc
Quoted 46 lines
2.
cv18xx.dtsi: no compatible
cv1800b.dtsi: compatible for cv1800b-dwcmshc
sg2002.dtsi: compatible for sg2002-dwcmshcAs in the plic and clint controllers, the second option was chosen I consider this as a "guideline" and reformat the dtsis accordingly.
Quoted 39 lines
Quoted 39 lines
Quoted 34 lines
Signed-off-by Thomas Bonnefille <[email protected]>--- arch/riscv/boot/dts/sophgo/cv1800b.dtsi | 4 ++++ arch/riscv/boot/dts/sophgo/cv18xx.dtsi | 1 - 2 files changed, 4 insertions(+), 1 deletion(-)arch/riscv/boot/dts/sophgo/cv1800b.dtsi +4
-0@@ -25,3 +25,7 @@ &clint { &clk { compatible = "sophgo,cv1800-clk"; }; + +&sdhci0 { + compatible = "sophgo,cv1800b-dwcmshc"; +};arch/riscv/boot/dts/sophgo/cv18xx.dtsi +0
-1@@ -288,7 +288,6 @@ uart4: serial@41c0000 { }; sdhci0: mmc@4310000 { - compatible = "sophgo,cv1800b-dwcmshc"; reg = <0x4310000 0x1000>; interrupts = <36 IRQ_TYPE_LEVEL_HIGH>; clocks = <&clk CLK_AXI4_SD0>,Signature · 1 line
2.45.2Hi, Jisheng,
Is this change necessary? IIRC, the sdhci is the same across the whole series.
Hi,
sorry for being late, I was busy in the past 2.5 month. Per my understanding, the sdhci in cv1800b is the same as the one in sg200x. Maybe I'm wrong, but this was my impression when I cooked the sdhci driver patch for these SoCs.
Quoted 7 lines
Quoted 3 lines
I tend to agree with Inochi here, if it's same across all SoC, then no bother to split, it will cause more trouble to maintain..
To be honest, I agree with this to, but as a specific compatible for the SG2002 was created in commit
849e81817b9b, I thought that the best practice was to use it.
I'd like to take this chance to query DT maintainers: FWICT, in the past even if the PLIC is the same between SoCs, adding a new compatible for them seems a must. So when time goes on, the compatbile list would be longer and longer, is it really necessary? Can we just use the existing compatible string?
DT maintainers may answered the query in the past, if so, sorry for querying again.
Quoted 10 lines
Quoted 5 lines
Quoted 4 lines
Regards,
Inochi_______________________________________________
linux-riscv mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/linux-riscv
Re: [PATCH v2 1/6] riscv: dts: sophgo: Put sdhci compatible in dt of specific SoC
Quoted 20 lines · Jisheng Zhang
Quoted 5 lines · Thomas Bonnefille
Quoted 4 lines · Yixun Lan
Quoted 2 lines · Inochi Amaoto
Is this change necessary? IIRC, the sdhci is the same across the whole series.
sorry for being late, I was busy in the past 2.5 month. Per my understanding, the sdhci in cv1800b is the same as the one in sg200x. Maybe I'm wrong, but this was my impression when I cooked the sdhci driver patch for these SoCs.
Quoted 7 lines
Quoted 3 lines
I tend to agree with Inochi here, if it's same across all SoC, then no bother to split, it will cause more trouble to maintain..
To be honest, I agree with this to, but as a specific compatible for the SG2002 was created in commit
849e81817b9b, I thought that the best practice was to use it.
Quoted 7 lines
I'd like to take this chance to query DT maintainers: FWICT, in the past even if the PLIC is the same between SoCs, adding a new compatible for them seems a must. So when time goes on, the compatbile list would be longer and longer, is it really necessary? Can we just use the existing compatible string?
DT maintainers may answered the query in the past, if so, sorry for querying again.
For new integrations of an IP, yes, new specific compatibles please. New integrations may have different bugs etc, even if the IP itself is the same. If there's different SoCs that are the same die, but with elements fused off, then sure, use the same compatible.
I expect the list of compatibles in the binding to grow rather large, but that is fine. No one SoC is going to do anything other than something like compatible = "renesas,$soc-plic", "andestech,corecomplex-plic", "riscv,plic"; which I think is perfectly fine.
Samuel Holland
maintainerRe: [PATCH v2 1/6] riscv: dts: sophgo: Put sdhci compatible in dt of specific SoC
Hi Jisheng, Thomas,
Quoted 34 lines · Conor Dooley
Quoted 20 lines · Jisheng Zhang
Quoted 5 lines · Thomas Bonnefille
Quoted 4 lines · Yixun Lan
Quoted 2 lines · Inochi Amaoto
Is this change necessary? IIRC, the sdhci is the same across the whole series.
sorry for being late, I was busy in the past 2.5 month. Per my understanding, the sdhci in cv1800b is the same as the one in sg200x. Maybe I'm wrong, but this was my impression when I cooked the sdhci driver patch for these SoCs.
Quoted 7 lines
Quoted 3 lines
I tend to agree with Inochi here, if it's same across all SoC, then no bother to split, it will cause more trouble to maintain..
To be honest, I agree with this to, but as a specific compatible for the SG2002 was created in commit
849e81817b9b, I thought that the best practice was to use it.Quoted 7 lines
I'd like to take this chance to query DT maintainers: FWICT, in the past even if the PLIC is the same between SoCs, adding a new compatible for them seems a must. So when time goes on, the compatbile list would be longer and longer, is it really necessary? Can we just use the existing compatible string?
DT maintainers may answered the query in the past, if so, sorry for querying again.For new integrations of an IP, yes, new specific compatibles please. New integrations may have different bugs etc, even if the IP itself is the same. If there's different SoCs that are the same die, but with elements fused off, then sure, use the same compatible.
Quoted 4 lines
I expect the list of compatibles in the binding to grow rather large, but that is fine. No one SoC is going to do anything other than something like compatible = "renesas,$soc-plic", "andestech,corecomplex-plic", "riscv,plic"; which I think is perfectly fine.
And you can do the same thing here for the SDHCI controller: if you think sg200x has the same controller (and integration! e.g. number of clocks/resets) as cv1800b, then you should keep sophgo,cv1800b-dwcmshc as a fallback compatible string. Then the driver doesn't need any changes until/unless you eventually find some reason they are not compatible.
It's better to have a SoC-specific compatible string in the DT and not need it, than find out later you need one and not have it. :)
Regards,
Samuel
Re: [PATCH v2 1/6] riscv: dts: sophgo: Put sdhci compatible in dt of specific SoC
Quoted 42 lines · Samuel Holland
Hi Jisheng, Thomas,
Quoted 34 lines · Conor Dooley
Quoted 20 lines · Jisheng Zhang
Quoted 5 lines · Thomas Bonnefille
Quoted 4 lines · Yixun Lan
Quoted 2 lines · Inochi Amaoto
Is this change necessary? IIRC, the sdhci is the same across the whole series.
sorry for being late, I was busy in the past 2.5 month. Per my understanding, the sdhci in cv1800b is the same as the one in sg200x. Maybe I'm wrong, but this was my impression when I cooked the sdhci driver patch for these SoCs.
Quoted 7 lines
Quoted 3 lines
I tend to agree with Inochi here, if it's same across all SoC, then no bother to split, it will cause more trouble to maintain..
To be honest, I agree with this to, but as a specific compatible for the SG2002 was created in commit
849e81817b9b, I thought that the best practice was to use it.Quoted 7 lines
I'd like to take this chance to query DT maintainers: FWICT, in the past even if the PLIC is the same between SoCs, adding a new compatible for them seems a must. So when time goes on, the compatbile list would be longer and longer, is it really necessary? Can we just use the existing compatible string?
DT maintainers may answered the query in the past, if so, sorry for querying again.For new integrations of an IP, yes, new specific compatibles please. New integrations may have different bugs etc, even if the IP itself is the same. If there's different SoCs that are the same die, but with elements fused off, then sure, use the same compatible.
Quoted 4 lines
I expect the list of compatibles in the binding to grow rather large, but that is fine. No one SoC is going to do anything other than something like compatible = "renesas,$soc-plic", "andestech,corecomplex-plic", "riscv,plic"; which I think is perfectly fine.
Quoted 8 lines
And you can do the same thing here for the SDHCI controller: if you think sg200x has the same controller (and integration! e.g. number of clocks/resets) as cv1800b, then you should keep sophgo,cv1800b-dwcmshc as a fallback compatible string. Then the driver doesn't need any changes until/unless you eventually find some reason they are not compatible.
It's better to have a SoC-specific compatible string in the DT and not need it, than find out later you need one and not have it. :)
Good idea, this solution looks better! Thanks for the suggestion
Quoted 4 lines
Regards,
Samuel
Re: [PATCH v2 1/6] riscv: dts: sophgo: Put sdhci compatible in dt of specific SoC
In reply to Samuel HollandQuoted 48 lines · Samuel Holland
Hi Jisheng, Thomas,
Quoted 34 lines · Conor Dooley
Quoted 20 lines · Jisheng Zhang
Quoted 5 lines · Thomas Bonnefille
Quoted 4 lines · Yixun Lan
Quoted 2 lines · Inochi Amaoto
Is this change necessary? IIRC, the sdhci is the same across the whole series.
sorry for being late, I was busy in the past 2.5 month. Per my understanding, the sdhci in cv1800b is the same as the one in sg200x. Maybe I'm wrong, but this was my impression when I cooked the sdhci driver patch for these SoCs.
Quoted 7 lines
Quoted 3 lines
I tend to agree with Inochi here, if it's same across all SoC, then no bother to split, it will cause more trouble to maintain..
To be honest, I agree with this to, but as a specific compatible for the SG2002 was created in commit
849e81817b9b, I thought that the best practice was to use it.Quoted 7 lines
I'd like to take this chance to query DT maintainers: FWICT, in the past even if the PLIC is the same between SoCs, adding a new compatible for them seems a must. So when time goes on, the compatbile list would be longer and longer, is it really necessary? Can we just use the existing compatible string?
DT maintainers may answered the query in the past, if so, sorry for querying again.For new integrations of an IP, yes, new specific compatibles please. New integrations may have different bugs etc, even if the IP itself is the same. If there's different SoCs that are the same die, but with elements fused off, then sure, use the same compatible.
Quoted 4 lines
I expect the list of compatibles in the binding to grow rather large, but that is fine. No one SoC is going to do anything other than something like compatible = "renesas,$soc-plic", "andestech,corecomplex-plic", "riscv,plic"; which I think is perfectly fine.
And you can do the same thing here for the SDHCI controller: if you think sg200x has the same controller (and integration! e.g. number of clocks/resets) as cv1800b, then you should keep sophgo,cv1800b-dwcmshc as a fallback compatible string. Then the driver doesn't need any changes until/unless you eventually find some reason they are not compatible.
Quoted 6 lines
It's better to have a SoC-specific compatible string in the DT and not need it, than find out later you need one and not have it. :)
Regards,
Samuel
This is excellect and reasonable. I will take your advice for the DT change. With your suggetion, I think it may be acceptable to mark the low-profile SoC as the default value and let other override it.
Let take the clk as the example:
// in the base file cv18xx.dtsi
clk: clock-controller@3002000 {
// set the "sophgo,cv1800-clk" as the fallback.
compatible = "sophgo,cv1800-clk";
[...]
};// in the cv1800b.dtsi
// now no need for the clk override since we have the compatible // default.
// in the cv1812h.dtsi
// we still need this override as it is not compatible
&clk {
compatible = "sophgo,cv1810-clk";
};// in the sg2002.dtsi of the patch
// we need this override as it is also not compatible
&clk {
compatible = "sophgo,sg2000-clk";
};Do I understand correctly? Or we still need to duplicate these node for SoCs with different profiles.
Regards,
Inochi
PATCH v2 2/6 dt-bindings: interrupt-controller: Add SOPHGO SG2002 plic
In reply to Thomas BonnefilleAdd compatible string for SOPHGO SG2002 Platform-Level Interruter Controller.
--- .../devicetree/bindings/interrupt-controller/sifive,plic-1.0.0.yaml | 1 + 1 file changed, 1 insertion(+)
Documentation/devicetree/bindings/interrupt-controller/sifive,plic-1.0.0.yaml +1 -0
@@ -67,6 +67,7 @@ properties: - allwinner,sun20i-d1-plic - sophgo,cv1800b-plic - sophgo,cv1812h-plic + - sophgo,sg2002-plic - sophgo,sg2042-plic - thead,th1520-plic - const: thead,c900-plic
Signature · 1 line
2.45.2
Rob Herring
maintainerRe: [PATCH v2 2/6] dt-bindings: interrupt-controller: Add SOPHGO SG2002 plic
Quoted 4 lines · Thomas Bonnefille
Add compatible string for SOPHGO SG2002 Platform-Level Interruter Controller.
Signed-off-by Thomas Bonnefille <[email protected]>
Missing Conor's ack. When sending new versions, it is your responsibility to add tags.
Quoted 20 lines
--- .../devicetree/bindings/interrupt-controller/sifive,plic-1.0.0.yaml | 1 + 1 file changed, 1 insertion(+)Documentation/devicetree/bindings/interrupt-controller/sifive,plic-1.0.0.yaml +1
-0@@ -67,6 +67,7 @@ properties: - allwinner,sun20i-d1-plic - sophgo,cv1800b-plic - sophgo,cv1812h-plic + - sophgo,sg2002-plic - sophgo,sg2042-plic - thead,th1520-plic - const: thead,c900-plicSignature · 2 lines
-- 2.45.2
Conor Dooley
Acked-byRe: [PATCH v2 2/6] dt-bindings: interrupt-controller: Add SOPHGO SG2002 plic
Quoted 8 lines · Rob Herring
Quoted 4 lines · Thomas Bonnefille
Add compatible string for SOPHGO SG2002 Platform-Level Interruter Controller.
Signed-off-by Thomas Bonnefille <[email protected]>Missing Conor's ack. When sending new versions, it is your responsibility to add tags.
PATCH v2 3/6 dt-bindings: timer: Add SOPHGO SG2002 clint
In reply to Thomas BonnefilleAdd compatible string for SOPHGO SG2002 Core-Local Interrupt Controller.
--- Documentation/devicetree/bindings/timer/sifive,clint.yaml | 1 + 1 file changed, 1 insertion(+)
Documentation/devicetree/bindings/timer/sifive,clint.yaml +1 -0
@@ -40,6 +40,7 @@ properties: - allwinner,sun20i-d1-clint - sophgo,cv1800b-clint - sophgo,cv1812h-clint + - sophgo,sg2002-clint - thead,th1520-clint - const: thead,c900-clint - items:
Signature · 1 line
2.45.2
Re: [PATCH v2 3/6] dt-bindings: timer: Add SOPHGO SG2002 clint
Quoted 3 lines · Thomas Bonnefille
Add compatible string for SOPHGO SG2002 Core-Local Interrupt Controller.
Signed-off-by Thomas Bonnefille <[email protected]>
PATCH v2 4/6 dt-bindings: riscv: Add Sipeed LicheeRV Nano board compatibles
In reply to Thomas BonnefilleDocument the compatible strings for the Sipeed LicheeRV Nano B board which uses the SOPHGO SG2002 SoC.
--- Documentation/devicetree/bindings/riscv/sophgo.yaml | 5 +++++ 1 file changed, 5 insertions(+)
Documentation/devicetree/bindings/riscv/sophgo.yaml +5 -0
@@ -26,6 +26,11 @@ properties: - enum: - sophgo,huashan-pi - const: sophgo,cv1812h + - items: + - enum: + - sipeed,licheerv-nano-b + - const: sipeed,licheerv-nano + - const: sophgo,sg2002 - items: - enum: - milkv,pioneer
Signature · 1 line
2.45.2
Re: [PATCH v2 4/6] dt-bindings: riscv: Add Sipeed LicheeRV Nano board compatibles
Quoted 4 lines · Thomas Bonnefille
Document the compatible strings for the Sipeed LicheeRV Nano B board which uses the SOPHGO SG2002 SoC.
Signed-off-by Thomas Bonnefille <[email protected]>
PATCH v2 5/6 riscv: dts: sophgo: Add initial SG2002 SoC device tree
In reply to Thomas BonnefilleAdd initial device tree for the SG2002 RISC-V SoC by SOPHGO.
--- arch/riscv/boot/dts/sophgo/sg2002.dtsi | 34 ++++++++++++++++++++++++++++++++++ 1 file changed, 34 insertions(+)
arch/riscv/boot/dts/sophgo/sg2002.dtsi new file +34 -0
@@ -0,0 +1,34 @@ +// SPDX-License-Identifier: (GPL-2.0 OR MIT) +/* + * Copyright (C) 2024 Thomas Bonnefille <[email protected]> + */ + +/dts-v1/; + +#include <dt-bindings/interrupt-controller/irq.h> +#include "cv18xx.dtsi" + +/ { + compatible = "sophgo,sg2002"; + + memory@80000000 { + device_type = "memory"; + reg = <0x80000000 0x10000000>; + }; +}; + +&plic { + compatible = "sophgo,sg2002-plic", "thead,c900-plic"; +}; + +&clint { + compatible = "sophgo,sg2002-clint", "thead,c900-clint"; +}; + +&clk { + compatible = "sophgo,sg2000-clk"; +}; + +&sdhci0 { + compatible = "sophgo,sg2002-dwcmshc"; +};
Signature · 1 line
2.45.2
Samuel Holland
maintainerRe: [PATCH v2 5/6] riscv: dts: sophgo: Add initial SG2002 SoC device tree
Hi Thomas,
Quoted 13 lines · Thomas Bonnefille
Add initial device tree for the SG2002 RISC-V SoC by SOPHGO.
Signed-off-by Thomas Bonnefille <[email protected]>--- arch/riscv/boot/dts/sophgo/sg2002.dtsi | 34 ++++++++++++++++++++++++++++++++++ 1 file changed, 34 insertions(+)arch/riscv/boot/dts/sophgo/sg2002.dtsi new file +0
-0
arch/riscv/boot/dts/sophgo/sg2002.dtsi line 6
Quoted 6 lines
arch/riscv/boot/dts/sophgo/sg2002.dtsi new file +6
-0@@ -0,0 +1,34 @@ +// SPDX-License-Identifier: (GPL-2.0 OR MIT) +/* + * Copyright (C) 2024 Thomas Bonnefille <[email protected]> + */ + +/dts-v1/;
While it doesn't hurt, you don't need this directive in both the .dtsi and each .dts file. It looks like it usually goes in the board .dts file only.
Regards,
Samuel
Quoted 29 lines
arch/riscv/boot/dts/sophgo/sg2002.dtsi new file +28
-0+ +#include <dt-bindings/interrupt-controller/irq.h> +#include "cv18xx.dtsi" + +/ { + compatible = "sophgo,sg2002"; + + memory@80000000 { + device_type = "memory"; + reg = <0x80000000 0x10000000>; + }; +}; + +&plic { + compatible = "sophgo,sg2002-plic", "thead,c900-plic"; +}; + +&clint { + compatible = "sophgo,sg2002-clint", "thead,c900-clint"; +}; + +&clk { + compatible = "sophgo,sg2000-clk"; +}; + +&sdhci0 { + compatible = "sophgo,sg2002-dwcmshc"; +};
PATCH v2 6/6 riscv: dts: sophgo: Add LicheeRV Nano board device tree
In reply to Thomas BonnefilleLicheeRV Nano B [1] is an embedded development platform based on the SOPHGO SG2002 chip, the B(ase) version is deprived of Wifi/Bluetooth and Ethernet.
Add only support for UART and SDHCI.
--- arch/riscv/boot/dts/sophgo/Makefile | 1 + .../boot/dts/sophgo/sg2002-licheerv-nano-b.dts | 53 ++++++++++++++++++++++ 2 files changed, 54 insertions(+)
arch/riscv/boot/dts/sophgo/Makefile +1 -0
@@ -1,4 +1,5 @@ # SPDX-License-Identifier: GPL-2.0 dtb-$(CONFIG_ARCH_SOPHGO) += cv1800b-milkv-duo.dtb dtb-$(CONFIG_ARCH_SOPHGO) += cv1812h-huashan-pi.dtb +dtb-$(CONFIG_ARCH_SOPHGO) += sg2002-licheerv-nano-b.dtb dtb-$(CONFIG_ARCH_SOPHGO) += sg2042-milkv-pioneer.dtb
arch/riscv/boot/dts/sophgo/sg2002-licheerv-nano-b.dts new file +53 -0
53 lines not on this page · raw message
Signature · 1 line
2.45.2
Re: [PATCH v2 6/6] riscv: dts: sophgo: Add LicheeRV Nano board device tree
Quoted 60 lines · Thomas Bonnefille
LicheeRV Nano B [1] is an embedded development platform based on the SOPHGO SG2002 chip, the B(ase) version is deprived of Wifi/Bluetooth and Ethernet.
Add only support for UART and SDHCI.
Signed-off-by Thomas Bonnefille <[email protected]>--- arch/riscv/boot/dts/sophgo/Makefile | 1 + .../boot/dts/sophgo/sg2002-licheerv-nano-b.dts | 53 ++++++++++++++++++++++ 2 files changed, 54 insertions(+)arch/riscv/boot/dts/sophgo/Makefile +1
-0@@ -1,4 +1,5 @@ # SPDX-License-Identifier: GPL-2.0 dtb-$(CONFIG_ARCH_SOPHGO) += cv1800b-milkv-duo.dtb dtb-$(CONFIG_ARCH_SOPHGO) += cv1812h-huashan-pi.dtb +dtb-$(CONFIG_ARCH_SOPHGO) += sg2002-licheerv-nano-b.dtb dtb-$(CONFIG_ARCH_SOPHGO) += sg2042-milkv-pioneer.dtbarch/riscv/boot/dts/sophgo/sg2002-licheerv-nano-b.dts new file +31
-0@@ -0,0 +1,53 @@ +// SPDX-License-Identifier: (GPL-2.0 OR MIT) +/* + * Copyright (C) 2024 Thomas Bonnefille <[email protected]> + */ + +/dts-v1/; + +#include "sg2002.dtsi" + +/ { + model = "LicheeRV Nano B"; + compatible = "sipeed,licheerv-nano-b", "sipeed,licheerv-nano", "sophgo,sg2002"; + + aliases { + gpio0 = &gpio0; + gpio1 = &gpio1; + gpio2 = &gpio2; + gpio3 = &gpio3; + serial0 = &uart0; + serial1 = &uart1; + serial2 = &uart2; + serial3 = &uart3; + serial4 = &uart4; + }; + + chosen { + stdout-path = "serial0:115200n8"; + }; +}; + +&osc {
arch/riscv/boot/dts/sophgo/sg2002-licheerv-nano-b.dts line 41
Quoted 10 lines
arch/riscv/boot/dts/sophgo/sg2002-licheerv-nano-b.dts new file +10
-0+ clock-frequency = <25000000>; +}; + +&sdhci0 { + status = "okay"; + bus-width = <4>; + no-1-8-v; + no-mmc; + no-sdio; +};
Please add "disable-wp" property. Otherwise the card will be probed as read-only.
Quoted 16 lines
arch/riscv/boot/dts/sophgo/sg2002-licheerv-nano-b.dts new file +12
-0+ +&uart0 { + status = "okay"; +}; + +&uart1 { + status = "okay"; +}; + +&i2c0 { + status = "okay"; +};Signature · 2 lines
-- 2.45.2