Drop EDID cache for it6505/anx7625 when the bridge is powered off
Subsystems (3)
cover Drop EDID cache for it6505/anx7625 when the bridge is powered off
This mainly fixes the use case when the user changes the external monitor when the system is suspended. Without this series, both of the bridges will skip the EDID read and returned the cached one after resume.
Apart from that, we also observed a DP-to-HDMI bridge expects an EDID read after it's powered on. This patch also works around the problem by always triggering the EDID read after the system resume.
Pin-yen Lin (2):
drm/bridge: anx7625: Drop EDID cache on bridge power off drm/bridge: it6505: Drop EDID cache on bridge power off
drivers/gpu/drm/bridge/analogix/anx7625.c | 1 + drivers/gpu/drm/bridge/ite-it6505.c | 2 ++ 2 files changed, 3 insertions(+)
Signature · 1 line
2.46.0.792.g87dc391469-goog
PATCH 1/2 drm/bridge: anx7625: Drop EDID cache on bridge power off
The bridge might miss the display change events when it's powered off. This happens when a user changes the external monitor when the system is suspended and the embedded controller doesn't not wake AP up.
It's also observed that one DP-to-HDMI bridge doesn't work correctly when there is no EDID read after it is powered on.
Drop the cache to force an EDID read after system resume to fix this.
---
drivers/gpu/drm/bridge/analogix/anx7625.c | 1 + 1 file changed, 1 insertion(+)
drivers/gpu/drm/bridge/analogix/anx7625.c +1 -0
@@ -2561,6 +2561,7 @@ static int __maybe_unused anx7625_runtime_pm_suspend(struct device *dev)mutex_lock (&ctx->lock);anx7625_stop_dp_work (ctx); +anx7625_remove_edid (ctx);anx7625_power_standby (ctx);mutex_unlock (&ctx->lock);
Signature · 1 line
2.46.0.792.g87dc391469-goog
Re: [PATCH 1/2] drm/bridge: anx7625: Drop EDID cache on bridge power off
Quoted 7 lines · Pin-yen Lin
The bridge might miss the display change events when it's powered off. This happens when a user changes the external monitor when the system is suspended and the embedded controller doesn't not wake AP up.
It's also observed that one DP-to-HDMI bridge doesn't work correctly when there is no EDID read after it is powered on.
Quoted 9 lines
Drop the cache to force an EDID read after system resume to fix this.
Fixes 8bdfc5dae4e3 ("drm/bridge: anx7625: Add anx7625 MIPI DSI/DPI to DP")Signed-off-by Pin-yen Lin <[email protected]>---
drivers/gpu/drm/bridge/analogix/anx7625.c | 1 + 1 file changed, 1 insertion(+)
Signature · 2 lines
With best wishes Dmitry
Re: [PATCH 1/2] drm/bridge: anx7625: Drop EDID cache on bridge power off
In reply to Pin-yen LinHi,
Quoted 8 lines · Pin-yen Lin
The bridge might miss the display change events when it's powered off. This happens when a user changes the external monitor when the system is suspended and the embedded controller doesn't not wake AP up.
It's also observed that one DP-to-HDMI bridge doesn't work correctly when there is no EDID read after it is powered on.
Quoted 8 lines
Drop the cache to force an EDID read after system resume to fix this.
Fixes 8bdfc5dae4e3 ("drm/bridge: anx7625: Add anx7625 MIPI DSI/DPI to DP")Signed-off-by Pin-yen Lin <[email protected]>---
drivers/gpu/drm/bridge/analogix/anx7625.c | 1 + 1 file changed, 1 insertion(+)
I'm not totally sure if it matters, but I wonder if you should change this to only delete the EDID cache if you're in DP mode and not eDP mode? For eDP mode the panel is not allowed to change and re-reading it needlessly seems like it would slow down things like suspend/resume. I think this would only matter if someone were using eDP panels in the "old" way (not under the aux-bus) because we don't set the "DRM_BRIDGE_OP_EDID" when we see "aux-bus", so maybe we don't care that much but still...
Other than that, I know that there have been discussions in the past about EDID caches but I can't quite remember all the details. I know that panel-edp.c still caches it, so we must have concluded that it's at least fine/reasonable for panels. I don't remember whether caching is encouraged / suggested for external displays, though. Do you happen to know if it even makes a difference there (in other words, do you actually see multiple calls to read the EDID when you plug in a DP display)?
-Doug
Re: [PATCH 1/2] drm/bridge: anx7625: Drop EDID cache on bridge power off
Hi,
Quoted 21 lines · Doug Anderson
Hi,
Quoted 8 lines · Pin-yen Lin
The bridge might miss the display change events when it's powered off. This happens when a user changes the external monitor when the system is suspended and the embedded controller doesn't not wake AP up.
It's also observed that one DP-to-HDMI bridge doesn't work correctly when there is no EDID read after it is powered on.
Quoted 8 lines
Drop the cache to force an EDID read after system resume to fix this.
Fixes 8bdfc5dae4e3 ("drm/bridge: anx7625: Add anx7625 MIPI DSI/DPI to DP")Signed-off-by Pin-yen Lin <[email protected]>---
drivers/gpu/drm/bridge/analogix/anx7625.c | 1 + 1 file changed, 1 insertion(+)
Quoted 8 lines
I'm not totally sure if it matters, but I wonder if you should change this to only delete the EDID cache if you're in DP mode and not eDP mode? For eDP mode the panel is not allowed to change and re-reading it needlessly seems like it would slow down things like suspend/resume. I think this would only matter if someone were using eDP panels in the "old" way (not under the aux-bus) because we don't set the "
DRM_BRIDGE_OP_EDID" when we see "aux-bus", so maybe we don't care that much but still...
I'll update this in v2.
Quoted 9 lines
Other than that, I know that there have been discussions in the past about EDID caches but I can't quite remember all the details. I know that
panel-edp.cstill caches it, so we must have concluded that it's at least fine/reasonable for panels. I don't remember whether caching is encouraged / suggested for external displays, though. Do you happen to know if it even makes a difference there (in other words, do you actually see multiple calls to read the EDID when you plug in a DP display)?
At least on ChromeOS, Chrome triggers two EDID reads when I plug in an external monitor. I'm not sure if this is common for other DRM masters though.
Quoted 2 lines
-Doug
Regards,
Pin-yen
PATCH 2/2 drm/bridge: it6505: Drop EDID cache on bridge power off
In reply to Pin-yen LinThe bridge might miss the display change events when it's powered off. This happens when a user changes the external monitor when the system is suspended and the embedded controller doesn't not wake AP up.
It's also observed that one DP-to-HDMI bridge doesn't work correctly when there is no EDID read after it is powered on.
Drop the cache to force an EDID read after system resume to fix this.
---
drivers/gpu/drm/bridge/ite-it6505.c | 2 ++ 1 file changed, 2 insertions(+)
drivers/gpu/drm/bridge/ite-it6505.c +2 -0
@@ -3101,6 +3101,8 @@ static __maybe_unused int it6505_bridge_suspend(struct device *dev) {struct it6505 *it6505 =dev_get_drvdata (dev); +it6505_remove_edid (it6505); +return it6505_poweroff (it6505); }
Signature · 1 line
2.46.0.792.g87dc391469-goog
Re: [PATCH 2/2] drm/bridge: it6505: Drop EDID cache on bridge power off
Quoted 9 lines · Pin-yen Lin
The bridge might miss the display change events when it's powered off. This happens when a user changes the external monitor when the system is suspended and the embedded controller doesn't not wake AP up.
It's also observed that one DP-to-HDMI bridge doesn't work correctly when there is no EDID read after it is powered on.
Drop the cache to force an EDID read after system resume to fix this.
Quoted 8 lines
Fixes 11feaef69d0c ("drm/bridge: it6505: Add caching for EDID")Signed-off-by Pin-yen Lin <[email protected]>---
drivers/gpu/drm/bridge/ite-it6505.c | 2 ++ 1 file changed, 2 insertions(+)
Signature · 2 lines
With best wishes Dmitry
Re: [PATCH 2/2] drm/bridge: it6505: Drop EDID cache on bridge power off
In reply to Pin-yen LinHi,
Quoted 5 lines · Pin-yen Lin
The bridge might miss the display change events when it's powered off. This happens when a user changes the external monitor when the system is suspended and the embedded controller doesn't not wake AP up.
Quoted 7 lines
It's also observed that one DP-to-HDMI bridge doesn't work correctly when there is no EDID read after it is powered on.
Drop the cache to force an EDID read after system resume to fix this.
Fixes 11feaef69d0c ("drm/bridge: it6505: Add caching for EDID")Signed-off-by Pin-yen Lin <[email protected]>
Ah, I guess this answers my question in the previous patch about whether caching was important even for external displays since this driver only supports external DP and the commit you mention in "Fixes" says that caching was important.
So this looks reasonable. One thing I wonder is if you're totally guaranteed to get a PM Runtime suspend whenever you get an unplug / replug of a display. I tried to dig a little bit but I'm not super familiar with this bridge and it looks complicated enough that I guess I'll have to trust that it's fine. So...
Re: [PATCH 2/2] drm/bridge: it6505: Drop EDID cache on bridge power off
Hi,
Quoted 22 lines · Doug Anderson
Hi,
Quoted 5 lines · Pin-yen Lin
The bridge might miss the display change events when it's powered off. This happens when a user changes the external monitor when the system is suspended and the embedded controller doesn't not wake AP up.
Quoted 7 lines
It's also observed that one DP-to-HDMI bridge doesn't work correctly when there is no EDID read after it is powered on.
Drop the cache to force an EDID read after system resume to fix this.
Fixes 11feaef69d0c ("drm/bridge: it6505: Add caching for EDID")Signed-off-by Pin-yen Lin <[email protected]>Ah, I guess this answers my question in the previous patch about whether caching was important even for external displays since this driver only supports external DP and the commit you mention in "Fixes" says that caching was important.
Quoted 5 lines
So this looks reasonable. One thing I wonder is if you're totally guaranteed to get a PM Runtime suspend whenever you get an unplug / replug of a display. I tried to dig a little bit but I'm not super familiar with this bridge and it looks complicated enough that I guess I'll have to trust that it's fine. So...
it6505_remove_edid() is also called when the bridge reads HPD low in the IRQ handler or the DPCD sink count changes to 0 after a HPD_IRQ signal. The assumption here is that if the bridge is still powered on, then it should be aware of the monitor change events and drop the EDID cache when needed. This patch addresses the scenario where monitor changes are not communicated to the bridge when it is powered off.
Quoted 2 lines
Reviewed-by Douglas Anderson <[email protected]>
Regards,
Pin-yen