clocksource/drivers/timer-ti-dm: Don't fail probe if int not found
PATCH v2 1/1 clocksource/drivers/timer-ti-dm: Don't fail probe if int not found
Some timers may not have an interrupt routed to the A53 GIC, but the timer PWM functionality can still be used by Linux Kernel. Therefore, do not fail probe if interrupt is not found and ti,timer-pwm exists.
---
Changes since v1:
- Switch to dev_info()
- Drop fixes tag
Link to v1: https://lore.kernel.org/all/[email protected]/
--- drivers/clocksource/timer-ti-dm.c | 8 ++++++-- 1 file changed, 6 insertions(+), 2 deletions(-)
drivers/clocksource/timer-ti-dm.c +6 -2
@@ -1104,8 +1104,12 @@ static int omap_dm_timer_probe(struct platform_device *pdev)return -ENOMEM ; timer->irq =platform_get_irq (pdev,0 ); -if (timer->irq <0 ) -return timer->irq; +if (timer->irq <0 ) { +if (of_property_read_bool (dev->of_node,"ti,timer-pwm" )) +dev_info (dev,"Did not find timer interrupt, timer usable in PWM mode only\n" ); +else +return timer->irq; + } timer->io_base =devm_platform_ioremap_resource (pdev,0 );if (IS_ERR (timer->io_base))
base-commit: d3d1556696c1a993eec54ac585fe5bf677e07474
Signature · 1 line
2.47.0
Daniel Lezcano
AppliedQuoted 7 lines · Judith Mendez
Some timers may not have an interrupt routed to the A53 GIC, but the timer PWM functionality can still be used by Linux Kernel. Therefore, do not fail probe if interrupt is not found and ti,timer-pwm exists.
Signed-off-by Judith Mendez <[email protected]>---
Applied, thanks
Signature · 5 lines
<http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs Follow Linaro: <http://www.facebook.com/pages/Linaro> Facebook | <http://twitter.com/#!/linaroorg> Twitter | <http://www.linaro.org/linaro-blog/> Blog
The following commit has been merged into the timers/core branch of tip:
The following commit has been merged into the timers/core branch of tip:
Commit-ID: 314413317b6d78cc76cd48f0296fde9fcfdec400 Gitweb: https://git.kernel.org/tip/314413317b6d78cc76cd48f0296fde9fcfdec400 Author: Judith Mendez <[email protected]> AuthorDate: Fri, 11 Oct 2024 12:52:03 -05:00 Committer: Daniel Lezcano <[email protected]> CommitterDate: Wed, 13 Nov 2024 13:49:33 +01:00
clocksource/drivers/timer-ti-dm: Don't fail probe if int not found
Some timers may not have an interrupt routed to the A53 GIC, but the timer PWM functionality can still be used by Linux Kernel. Therefore, do not fail probe if interrupt is not found and ti,timer-pwm exists.
--- drivers/clocksource/timer-ti-dm.c | 8 ++++++-- 1 file changed, 6 insertions(+), 2 deletions(-)
drivers/clocksource/timer-ti-dm.c +6 -2
@@ -1104,8 +1104,12 @@ static int omap_dm_timer_probe(struct platform_device *pdev)return -ENOMEM ; timer->irq =platform_get_irq (pdev,0 ); -if (timer->irq <0 ) -return timer->irq; +if (timer->irq <0 ) { +if (of_property_read_bool (dev->of_node,"ti,timer-pwm" )) +dev_info (dev,"Did not find timer interrupt, timer usable in PWM mode only\n" ); +else +return timer->irq; + } timer->io_base =devm_platform_ioremap_resource (pdev,0 );if (IS_ERR (timer->io_base))