rtc: ab-eoz9: fix abeoz9_rtc_read_alarm
[email protected]
maintainerPATCH v2 1/1 rtc: ab-eoz9: fix abeoz9_rtc_read_alarm
From: Alexandre Belloni <[email protected]>
abeoz9_rtc_read_alarm assumes we always read the alarm in 12-hour mode while abeoz9_rtc_set_alarm will always set it in 24-hour mode.
We could support 12-hour mode in both functions but it seems very unlikely that the RTC would be set to 12-hour mode now as the driver has been setting it to 24-hour mode for a while now. The setting is undefined at power-up and unchanged by subsequent resets which doesn't help us.
Signed-off-by Alexandre Belloni <[email protected]>
---
Changes in v2:
- remove left over from development
drivers/rtc/rtc-ab-eoz9.c | 4 +--- 1 file changed, 1 insertion(+), 3 deletions(-)
drivers/rtc/rtc-ab-eoz9.c +1 -3
@@ -64,7 +64,7 @@#define ABEOZ9_BIT_ALARM_MIN GENMASK(6, 0)#define ABEOZ9_REG_ALARM_HOURS 0x12#define ABEOZ9_BIT_ALARM_HOURS_PM BIT(5) -#define ABEOZ9_BIT_ALARM_HOURS GENMASK(4, 0) +#define ABEOZ9_BIT_ALARM_HOURS GENMASK(5, 0)#define ABEOZ9_REG_ALARM_DAYS 0x13#define ABEOZ9_BIT_ALARM_DAYS GENMASK(5, 0)#define ABEOZ9_REG_ALARM_WEEKDAYS 0x14
@@ -231,8 +231,6 @@ static int abeoz9_rtc_read_alarm(struct device *dev, struct rtc_wkalrm *alarm) alarm->time.tm_sec =bcd2bin (FIELD_GET (ABEOZ9_BIT_ALARM_SEC , regs[0 ])); alarm->time.tm_min =bcd2bin (FIELD_GET (ABEOZ9_BIT_ALARM_MIN , regs[1 ])); alarm->time.tm_hour =bcd2bin (FIELD_GET (ABEOZ9_BIT_ALARM_HOURS , regs[2 ])); -if (FIELD_GET (ABEOZ9_BIT_ALARM_HOURS_PM , regs[2 ])) - alarm->time.tm_hour +=12 ; alarm->time.tm_mday =bcd2bin (FIELD_GET (ABEOZ9_BIT_ALARM_DAYS , regs[3 ]));