Skip to contentSkip to conversation

iio: light: veml6030: add support for triggered buffer

PATCH Applied Javier Carrasco 2 participants 2 messages Nov 24, 2024 – Dec 1, 2024

Subsystems (2)
lore
Share & tools
lore

Javier Carrasco

author maintainer
#0 lore raw

PATCH v3 1/1 iio: light: veml6030: add support for triggered buffer

All devices supported by this driver (currently veml6030, veml6035 and veml7700) have two 16-bit channels, and can profit for the same configuration to support data access via triggered buffers.

The measurements are stored in two 16-bit consecutive registers (addresses 0x04 and 0x05) as little endian, unsigned data.

---
Changes in v3:
- Ensure that the holes in the scan struct are initialized to zero.
- Link to v2: https://lore.kernel.org/r/[email protected]

Changes in v2:
- Use u16 instead of __le16 for the channels.
- Move scan struct from data to trigger_handler.
- Drop avail_scan_masks.
- Fix scan_type (IIO_CPU instead of IIO_LE, drop shift = 0).
- Link to v1: https://lore.kernel.org/r/[email protected]

---
 drivers/iio/light/Kconfig    |  2 ++
 drivers/iio/light/veml6030.c | 76 ++++++++++++++++++++++++++++++++++++++++++++
 2 files changed, 78 insertions(+)
drivers/iio/light/Kconfig +2 -0
index 29ffa8491927..0e2566ff5f7b 100644
@@ -683,6 +683,8 @@ config VEML3235
 config VEML6030
 	tristate "VEML6030 and VEML6035 ambient light sensors"
 	select REGMAP_I2C
+	select IIO_BUFFER
+	select IIO_TRIGGERED_BUFFER
 	depends on I2C
 	help
 	  Say Y here if you want to build a driver for the Vishay VEML6030
drivers/iio/light/veml6030.c +76 -0

132 lines not on this page · raw message

---
base-commit: ab376e4d674037f45d5758c1dc391bd4e11c5dc4
change-id: 20241106-veml6030_triggered_buffer-a38886ca4cce

Best regards,

Signature · 1 line
Javier Carrasco <[email protected]>
maintainer Applied
#1 lore raw
Quoted 8 lines · On Sun, 24 Nov 2024 19:59:06 +0100 Javier Carrasco…

All devices supported by this driver (currently veml6030, veml6035 and veml7700) have two 16-bit channels, and can profit for the same configuration to support data access via triggered buffers.

The measurements are stored in two 16-bit consecutive registers (addresses 0x04 and 0x05) as little endian, unsigned data.

Applied.

Thanks for this and for fixing up the other cases where holes weren't initialized right!

Jonathan