cifs: Cleanup of duplicated structures
Subsystems (2)
cover cifs: Cleanup of duplicated structures
This patch series contains only code cleanup of few duplicates structures and enums between smb/common and smb/client subdirs. No function change.
Can be useful also for ksmbd server part.
Pali Rohár (3):
cifs: Remove struct reparse_posix_data from struct cifs_open_info_data
cifs: Remove duplicate struct reparse_symlink_data and
SYMLINK_FLAG_RELATIVE
cifs: Rename struct reparse_posix_data to reparse_nfs_data_buffer and
move to common/smb2pdu.h
fs/smb/client/cifsglob.h | 5 +---- fs/smb/client/cifspdu.h | 30 ------------------------------ fs/smb/client/reparse.c | 15 +++++++-------- fs/smb/common/smb2pdu.h | 14 +++++++++++++- 4 files changed, 21 insertions(+), 43 deletions(-)
Signature · 1 line
2.20.1
PATCH 1/3 cifs: Remove struct reparse_posix_data from struct cifs_open_info_data
Linux SMB client already supports more reparse point types but only the reparse_posix_data is defined in union of struct cifs_open_info_data. This union is currently used as implicit casting between point types.
With this code style, it hides information that union is used for pointer casting, and just in mknod_nfs() and posix_reparse_to_fattr() functions.
Other reparse point buffers do not use this kind of casting. So remove reparse_posix_data from reparse part of struct cifs_open_info_data and for all cases of reparse buffer use just struct reparse_data_buffer *buf.
--- fs/smb/client/cifsglob.h | 5 +---- fs/smb/client/reparse.c | 5 ++--- 2 files changed, 3 insertions(+), 7 deletions(-)
fs/smb/client/cifsglob.h +1 -4
@@ -262,10 +262,7 @@ struct cifs_open_info_data {struct kvec iov; } io;__u32 tag; -union { -struct reparse_data_buffer *buf; -struct reparse_posix_data *posix; - }; +struct reparse_data_buffer *buf; } reparse;struct {__u8 eas[SMB2_WSL_MAX_QUERY_EA_RESP_SIZE ];
fs/smb/client/reparse.c +2 -3
@@ -486,7 +486,7 @@ static int mknod_nfs(unsigned int xid, struct inode *inode, data = (struct cifs_open_info_data ) { .reparse_point = true, - .reparse = { .tag =IO_REPARSE_TAG_NFS , .posix = p, }, + .reparse = { .tag =IO_REPARSE_TAG_NFS , .buf = (struct reparse_data_buffer *)p, }, .symlink_target =kstrdup (symname,GFP_KERNEL ), };
@@ -1165,8 +1165,7 @@ static bool posix_reparse_to_fattr(struct cifs_sb_info *cifs_sb,struct cifs_fattr *fattr, struct cifs_open_info_data *data) { - struct reparse_posix_data *buf = data->reparse.posix; - + struct reparse_posix_data *buf = (struct reparse_posix_data *)data->reparse.buf;if (buf ==NULL )return true;
Signature · 1 line
2.20.1
PATCH 2/3 cifs: Remove duplicate struct reparse_symlink_data and SYMLINK_FLAG_RELATIVE
In reply to Pali RohárIn file common/smb2pdu.h is defined struct reparse_symlink_data_buffer which is same as struct reparse_symlink_data and is used in the whole code. So remove duplicate struct reparse_symlink_data from client/cifspdu.h.
In file common/smb2pdu.h is defined also SYMLINK_FLAG_RELATIVE constant, so remove duplication from client/cifspdu.h.
--- fs/smb/client/cifspdu.h | 16 ---------------- 1 file changed, 16 deletions(-)
fs/smb/client/cifspdu.h +0 -16
@@ -1485,22 +1485,6 @@ struct file_notify_information {__u8 FileName[]; } __attribute__((packed)); -/* For IO_REPARSE_TAG_SYMLINK */ -struct reparse_symlink_data { -__le32 ReparseTag; -__le16 ReparseDataLength; -__u16 Reserved; -__le16 SubstituteNameOffset; -__le16 SubstituteNameLength; -__le16 PrintNameOffset; -__le16 PrintNameLength; -__le32 Flags; -char PathBuffer[]; -} __attribute__((packed)); - -/* Flag above */ -#define SYMLINK_FLAG_RELATIVE 0x00000001 -/* For IO_REPARSE_TAG_NFS */ #define NFS_SPECFILE_LNK 0x00000000014B4E4C#define NFS_SPECFILE_CHR 0x0000000000524843
Signature · 1 line
2.20.1
PATCH 3/3 cifs: Rename struct reparse_posix_data to reparse_nfs_data_buffer and move to common/smb2pdu.h
In reply to Pali RohárFunction parse_reparse_posix() parses NFS-style reparse points, which are used only by Windows NFS server since Windows Server 2012 version. This style is not understood by Microsoft POSIX/Interix/SFU/SUA subsystems.
So make it clear that parse_reparse_posix() function and reparse_posix_data structure are not POSIX general, but rather NFS specific.
All reparse buffer structures are defined in common/smb2pdu.h and have _buffer suffix. So move struct reparse_posix_data from client/cifspdu.h to common/smb2pdu.h and rename it to reparse_nfs_data_buffer for consistency. Note that also SMB specification in [MS-FSCC] document, section 2.1.2.6 defines it under name "Network File System (NFS) Reparse Data Buffer". So use this name for consistency.
Having this structure in common/smb2pdu.h can be useful for ksmbd server code as NFS-style reparse points is the preferred way for implementing support for special files.
--- fs/smb/client/cifspdu.h | 14 -------------- fs/smb/client/reparse.c | 12 ++++++------ fs/smb/common/smb2pdu.h | 14 +++++++++++++- 3 files changed, 19 insertions(+), 21 deletions(-)
fs/smb/client/cifspdu.h +0 -14
@@ -1485,20 +1485,6 @@ struct file_notify_information {__u8 FileName[]; } __attribute__((packed)); -/* For IO_REPARSE_TAG_NFS */ -#define NFS_SPECFILE_LNK 0x00000000014B4E4C -#define NFS_SPECFILE_CHR 0x0000000000524843 -#define NFS_SPECFILE_BLK 0x00000000004B4C42 -#define NFS_SPECFILE_FIFO 0x000000004F464946 -#define NFS_SPECFILE_SOCK 0x000000004B434F53 -struct reparse_posix_data { -__le32 ReparseTag; -__le16 ReparseDataLength; -__u16 Reserved; -__le64 InodeType;/* LNK, FIFO, CHR etc. */ -__u8 DataBuffer[]; -} __attribute__((packed)); -struct cifs_quota_data {__u32 rsrvd1;/* 0 */ __u32 sid_size;
fs/smb/client/reparse.c +6 -6
@@ -407,7 +407,7 @@ static int create_native_socket(const unsigned int xid, struct inode *inode,return rc; } -static int nfs_set_reparse_buf(struct reparse_posix_data *buf, +static int nfs_set_reparse_buf(struct reparse_nfs_data_buffer *buf, mode_t mode, dev_t dev, __le16 *symname_utf16, int symname_utf16_len,
@@ -454,7 +454,7 @@ static int mknod_nfs(unsigned int xid, struct inode *inode, {struct cifs_sb_info *cifs_sb =CIFS_SB (inode->i_sb);struct cifs_open_info_data data; -struct reparse_posix_data *p =NULL ; +struct reparse_nfs_data_buffer *p =NULL ;__le16 *symname_utf16 =NULL ;int symname_utf16_len =0 ;struct inode *new;
@@ -478,7 +478,7 @@ static int mknod_nfs(unsigned int xid, struct inode *inode, goto out; } }else { - p = (struct reparse_posix_data *)buf; + p = (struct reparse_nfs_data_buffer *)buf; } rc =nfs_set_reparse_buf (p, mode, dev, symname_utf16, symname_utf16_len, &iov);if (rc)
@@ -716,7 +716,7 @@ int smb2_mknod_reparse(unsigned int xid, struct inode *inode, }/* See MS-FSCC 2.1.2.6 for the 'NFS' style reparse tags */ -static int parse_reparse_posix (struct reparse_posix_data *buf, +static int parse_reparse_nfs (struct reparse_nfs_data_buffer *buf,struct cifs_sb_info *cifs_sb,struct cifs_open_info_data *data) {
@@ -1069,7 +1069,7 @@ int parse_reparse_point(struct reparse_data_buffer *buf,/* See MS-FSCC 2.1.2 */ switch (le32_to_cpu (buf->ReparseTag)) {case IO_REPARSE_TAG_NFS : -return parse_reparse_posix ((struct reparse_posix_data *)buf, +return parse_reparse_nfs ((struct reparse_nfs_data_buffer *)buf, cifs_sb, data);case IO_REPARSE_TAG_SYMLINK : return parse_reparse_native_symlink(
@@ -1165,7 +1165,7 @@ static bool posix_reparse_to_fattr(struct cifs_sb_info *cifs_sb,struct cifs_fattr *fattr, struct cifs_open_info_data *data) { - struct reparse_posix_data *buf = (struct reparse_posix_data *)data->reparse.buf; + struct reparse_nfs_data_buffer *buf = (struct reparse_nfs_data_buffer *)data->reparse.buf;if (buf ==NULL )return true;
fs/smb/common/smb2pdu.h +13 -1
@@ -1550,7 +1550,19 @@ struct reparse_symlink_data_buffer {__u8 PathBuffer[];/* Variable Length */ } __packed; -/* See MS-FSCC 2.1.2.6 and cifspdu.h for struct reparse_posix_data */ +/* For IO_REPARSE_TAG_NFS - see MS-FSCC 2.1.2.6 */ +#define NFS_SPECFILE_LNK 0x00000000014B4E4C +#define NFS_SPECFILE_CHR 0x0000000000524843 +#define NFS_SPECFILE_BLK 0x00000000004B4C42 +#define NFS_SPECFILE_FIFO 0x000000004F464946 +#define NFS_SPECFILE_SOCK 0x000000004B434F53 +struct reparse_nfs_data_buffer { +__le32 ReparseTag; +__le16 ReparseDataLength; +__u16 Reserved; +__le64 InodeType;/* NFS_SPECFILE_* */ +__u8 DataBuffer[]; +} __packed;/* For IO_REPARSE_TAG_LX_SYMLINK */ struct reparse_wsl_symlink_data_buffer {
Signature · 1 line
2.20.1
Quoted 4 lines · Pali Rohár
This patch series contains only code cleanup of few duplicates structures and enums between smb/common and smb/client subdirs. No function change.
Quoted 8 lines
Can be useful also for ksmbd server part.
Pali Rohár (3):
cifs: Remove structreparse_posix_datafrom structcifs_open_info_data
cifs: Remove duplicate structreparse_symlink_dataand
SYMLINK_FLAG_RELATIVE
cifs: Rename structreparse_posix_datatoreparse_nfs_data_bufferand
move tocommon/smb2pdu.h
Looks good to me:)
Thanks!
Quoted 10 lines
fs/smb/client/cifsglob.h | 5 +---- fs/smb/client/cifspdu.h | 30 ------------------------------ fs/smb/client/reparse.c | 15 +++++++-------- fs/smb/common/smb2pdu.h | 14 +++++++++++++- 4 files changed, 21 insertions(+), 43 deletions(-)--
2.20.1