iio: magnetometer: si7210: fix magnetic field measurement scale
PATCH 1/1 iio: magnetometer: si7210: fix magnetic field measurement scale
Applying the current scale value to the raw magnetic field measurements gives the result in mT.
Fix the scale by increasing it 10 times, so that the final result after applying the scale is in Gauss.
--- drivers/iio/magnetometer/si7210.c | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-)
drivers/iio/magnetometer/si7210.c +4 -4
@@ -203,9 +203,9 @@ static int si7210_read_raw(struct iio_dev *indio_dev,case IIO_CHAN_INFO_SCALE : *val =0 ;if (data->curr_scale ==20 ) - *val2 =1250 ; -else /* data->curr_scale == 200 */ *val2 =12500 ; +else /* data->curr_scale == 200 */ + *val2 =125000 ;return IIO_VAL_INT_PLUS_MICRO ;case IIO_CHAN_INFO_OFFSET : *val =-16384 ;
@@ -274,9 +274,9 @@ static int si7210_write_raw(struct iio_dev *indio_dev,switch (mask) {case IIO_CHAN_INFO_SCALE : -if (val ==0 && val2 ==1250 ) +if (val ==0 && val2 ==12500 ) scale =20 ; -else if (val ==0 && val2 ==12500 ) +else if (val ==0 && val2 ==125000 ) scale =200 ;else return -EINVAL ;
base-commit: aa61400ca17e264a4b597e3c0cda011c6b9b3bb5
Signature · 1 line
2.25.1
Quoted 5 lines · Antoni Pokusinski
Applying the current scale value to the raw magnetic field measurements gives the result in mT.
Fix the scale by increasing it 10 times, so that the final result after applying the scale is in Gauss.
No objections against this change, just wondering since these are the ABI changes (correct?) how should we really handle them in case some of the user space stuff already relies on 'bad' values?
Signature · 2 lines
With Best Regards, Andy Shevchenko
Quoted 11 lines · On Mon, 3 Feb 2025 11:26:27 +0200 Andy Shevchenko…
Quoted 5 lines · Antoni Pokusinski
Applying the current scale value to the raw magnetic field measurements gives the result in mT.
Fix the scale by increasing it 10 times, so that the final result after applying the scale is in Gauss.
No objections against this change, just wondering since these are the ABI changes (correct?) how should we really handle them in case some of the user space stuff already relies on 'bad' values?
If it's broken wrt to the published ABI (and hence what other sensors are exporting) then not a whole lot we can do other than backport the fix. This is one of the few cases where ABI backwards compatibility comes second :(
Jonathan
Quoted 4 lines · Andy Shevchenko
Quoted 3 lines · Antoni Pokusinski
Applying the current scale value to the raw magnetic field measurements gives the result in mT.
Quoted 12 lines
Quoted 2 lines
Fix the scale by increasing it 10 times, so that the final result after applying the scale is in Gauss.
No objections against this change, just wondering since these are the ABI changes (correct?) how should we really handle them in case some of the user space stuff already relies on 'bad' values?
Signature · 2 lines
With Best Regards, Andy Shevchenko
Just to clarify: yes, this patch makes the output values compliant to ABI (Documentation/ABI/testing/sysfs-bus-iio). According to the ABI, the output values for the magnetic field should be in Gauss, but during the driver development I missed the fact that I return values in mT instead... (1 Gauss = 0.1mT)
BTW I see that the patch cb29542a178f ("iio: magnetometer: si7210: add driver for Si7210") is still on the "testing" branch only, so perhaps it's still not too late to apply the fix?
Kind regards,
Antoni
Jonathan Cameron
maintainerQuoted 24 lines · On Mon, 3 Feb 2025 20:39:20 +0100 Antoni Pokusinski <[email protected]>…
Quoted 4 lines · Andy Shevchenko
Quoted 3 lines · Antoni Pokusinski
Applying the current scale value to the raw magnetic field measurements gives the result in mT.
Quoted 12 lines
Quoted 2 lines
Fix the scale by increasing it 10 times, so that the final result after applying the scale is in Gauss.
No objections against this change, just wondering since these are the ABI changes (correct?) how should we really handle them in case some of the user space stuff already relies on 'bad' values?
Signature · 2 lines
With Best Regards, Andy ShevchenkoJust to clarify: yes, this patch makes the output values compliant to ABI (
Documentation/ABI/testing/sysfs-bus-iio). According to the ABI, the output values for the magnetic field should be in Gauss, but during the driver development I missed the fact that I return values in mT instead... (1 Gauss = 0.1mT)
Quoted 4 lines
BTW I see that the patch
cb29542a178f("iio: magnetometer: si7210: add driver for Si7210") is still on the "testing" branch only, so perhaps it's still not too late to apply the fix?
Ah. I'd not registered that. Definitely makes life easier. This will just get queued up behind it and land upstream at the same time.
Jonathan
Quoted 4 lines
Kind regards,
Antoni
Quoted 31 lines · On Tue, 4 Feb 2025 19:24:54 +0000 Jonathan Cameron <[email protected]> wrote:
Quoted 24 lines · On Mon, 3 Feb 2025 20:39:20 +0100 Antoni Pokusinski <[email protected]>…
Quoted 4 lines · Andy Shevchenko
Quoted 3 lines · Antoni Pokusinski
Applying the current scale value to the raw magnetic field measurements gives the result in mT.
Quoted 12 lines
Quoted 2 lines
Fix the scale by increasing it 10 times, so that the final result after applying the scale is in Gauss.
No objections against this change, just wondering since these are the ABI changes (correct?) how should we really handle them in case some of the user space stuff already relies on 'bad' values?
Signature · 2 lines
With Best Regards, Andy ShevchenkoJust to clarify: yes, this patch makes the output values compliant to ABI (
Documentation/ABI/testing/sysfs-bus-iio). According to the ABI, the output values for the magnetic field should be in Gauss, but during the driver development I missed the fact that I return values in mT instead... (1 Gauss = 0.1mT)Quoted 4 lines
BTW I see that the patch
cb29542a178f("iio: magnetometer: si7210: add driver for Si7210") is still on the "testing" branch only, so perhaps it's still not too late to apply the fix?
Quoted 5 lines
Ah. I'd not registered that. Definitely makes life easier. This will just get queued up behind it and land upstream at the same time.
Jonathan
Applied.
Quoted 7 lines
Quoted 5 lines
Kind regards,
Antoni