Skip to contentSkip to conversation

tests/functional: remove all class level fields

PATCH In review Daniel P. Berrangé 2 participants 2 messages Mar 17, 2025

lore
Share & tools
lore
#0 lore raw

PATCH v3 1/1 tests/functional: remove all class level fields

A number of fields are set at the class level on QemuBaseTest, even though the exact same named field is then set at the object level later in most cases.

The 'self.logger' initialization in ACPI bits test needs to be removed since 'self.log' won't exist at that point in the flow. It already initialized 'self.logger' later in the setUp() method, so the __init__ method was redundant.

---
 tests/functional/qemu_test/testcase.py | 6 ------
 tests/functional/test_acpi_bits.py     | 1 -
 2 files changed, 7 deletions(-)
tests/functional/qemu_test/testcase.py +0 -6
index 50d232a7c6..50c401b8c3 100644
@@ -33,12 +33,6 @@
 
 class QemuBaseTest(unittest.TestCase):
 
-    arch = None
-
-    workdir = None
-    log = None
-    logdir = None
-
     '''
     @params compressed: filename, Asset, or file-like object to uncompress
     @params format: optional compression format (gzip, lzma)
tests/functional/test_acpi_bits.py +0 -1
index 20da435687..8e0563a97b 100755
@@ -119,7 +119,6 @@ def __init__(self, *args, **kwargs):
 
         self._debugcon_addr = '0x403'
         self._debugcon_log = 'debugcon-log.txt'
-        self.logger = self.log
 
     def _print_log(self, log):
         self.logger.info('\nlogs from biosbits follows:')
Signature · 1 line
2.48.1
Reviewed-by on v3 1/1
#1 lore raw
Quoted 8 lines · Daniel P. Berrangé

A number of fields are set at the class level on QemuBaseTest, even though the exact same named field is then set at the object level later in most cases.

The 'self.logger' initialization in ACPI bits test needs to be removed since 'self.log' won't exist at that point in the flow. It already initialized 'self.logger' later in the setUp() method, so the __init__ method was redundant.

Thanks for tackling it!

Quoted 2 lines

---

... and queued it!