virtio_console: fix order of fields cols and rows
Subsystems (3)
PATCH 1/1 virtio_console: fix order of fields cols and rows
According to section 5.3.6.2 (Multiport Device Operation) of the virtio spec(version 1.2) a control buffer with the event VIRTIO_CONSOLE_RESIZE is followed by a virtio_console_resize struct containing cols then rows. The kernel implements this the wrong way around (rows then cols) resulting in the two values being swapped.
--- drivers/char/virtio_console.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/char/virtio_console.c +1 -1
@@ -1579,8 +1579,8 @@ static void handle_control_message(struct virtio_device *vdev,break ;case VIRTIO_CONSOLE_RESIZE : {struct { -__virtio16 rows;__virtio16 cols; +__virtio16 rows; } size;if (!is_console_port (port))
Signature · 1 line
2.48.1
Quoted 17 lines · Maximilian Immanuel Brandtner
According to section 5.3.6.2 (Multiport Device Operation) of the virtio spec(version 1.2) a control buffer with the event
VIRTIO_CONSOLE_RESIZEis followed by avirtio_console_resizestruct containing cols then rows. The kernel implements this the wrong way around (rows then cols) resulting in the two values being swapped.Signed-off-by Maximilian Immanuel Brandtner <[email protected]>--- drivers/char/virtio_console.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)drivers/char/virtio_console.c +0
-0
drivers/char/virtio_console.c static void handle_control_message(struct virtio_device *vdev, · line 1584
Quoted 7 lines
drivers/char/virtio_console.c +1
-1@@ -1579,8 +1579,8 @@ static void handle_control_message(struct virtio_device *vdev,break ;case VIRTIO_CONSOLE_RESIZE : {struct { -__virtio16 rows;__virtio16 cols; +__virtio16 rows; } size;
The order of the fields after the patch matches the spec, so from that perspective, looks fine:
Since the driver code has been using the wrong order since support for this message was added in 2010, but there is no support for sending this message in the current qemu device implementation, I wondered what device code was used to test this when it was originally added. I dug up what I assume is the corresponding qemu device change from the same era, which sends the VIRTIO_CONSOLE_RESIZE message using the rows, cols order that matches the kernel driver (and differs from the spec):
https://lore.kernel.org/qemu-devel/[email protected]/
("[Qemu-devel] [PATCH] virtio-serial: Send per-console port resize notifications to guest", May 6, 2010)
However, I don't believe that patch ever made it into an actual qemu release, so it's probably not a compatibility concern. (If there are any other device implementations that use the kernel driver order rather than the spec order, then maybe this would need more consideration, but I don't personally know of any.)
Thanks,
-- Daniel
Michael S. Tsirkin
maintainerQuoted 44 lines · Daniel Verkamp
Quoted 17 lines · Maximilian Immanuel Brandtner
According to section 5.3.6.2 (Multiport Device Operation) of the virtio spec(version 1.2) a control buffer with the event
VIRTIO_CONSOLE_RESIZEis followed by avirtio_console_resizestruct containing cols then rows. The kernel implements this the wrong way around (rows then cols) resulting in the two values being swapped.Signed-off-by Maximilian Immanuel Brandtner <[email protected]>--- drivers/char/virtio_console.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)drivers/char/virtio_console.c +0
-0drivers/char/virtio_console.c static void handle_control_message(struct virtio_device *vdev, · line 1584
Quoted 7 lines
drivers/char/virtio_console.c +1
-1@@ -1579,8 +1579,8 @@ static void handle_control_message(struct virtio_device *vdev,break ;case VIRTIO_CONSOLE_RESIZE : {struct { -__virtio16 rows;__virtio16 cols; +__virtio16 rows; } size;The order of the fields after the patch matches the spec, so from that perspective, looks fine:
Reviewed-by Daniel Verkamp <[email protected]>Since the driver code has been using the wrong order since support for this message was added in 2010, but there is no support for sending this message in the current qemu device implementation, I wondered what device code was used to test this when it was originally added. I dug up what I assume is the corresponding qemu device change from the same era, which sends the
VIRTIO_CONSOLE_RESIZEmessage using the rows, cols order that matches the kernel driver (and differs from the spec):https://lore.kernel.org/qemu-devel/[email protected]/
("[Qemu-devel] [PATCH] virtio-serial: Send per-console port resize notifications to guest", May 6, 2010)
Quoted 8 lines
However, I don't believe that patch ever made it into an actual qemu release, so it's probably not a compatibility concern. (If there are any other device implementations that use the kernel driver order rather than the spec order, then maybe this would need more consideration, but I don't personally know of any.)
Thanks,
-- Daniel
I agree. Cc author of the qemu patch for confirmation.
Signature · 1 line
MST