flow offload teardown when layer 2 roaming
Subsystems (3)
v2 cover flow offload teardown when layer 2 roaming
In case of a bridge in the forward-fastpath or bridge-fastpath the fdb is used to create the tuple. In case of roaming at layer 2 level, for example 802.11r, the destination device is changed in the fdb. The destination device of a direct transmitting tuple is no longer valid and traffic is send to the wrong destination. Also the hardware offloaded fastpath is not valid anymore.
This flowentry needs to be torn down asap. Also make sure that the flow entry is not being used, when marked for teardown.
Changes in v2:
- Unchanged, only tags RFC net-next to PATCH nf-next.
Eric Woudstra (3):
netfilter: flow: Add bridge_vid member
netfilter: nf_flow_table_core: teardown direct xmit when destination
changed
netfilter: nf_flow_table_ip: don't follow fastpath when marked
teardown
include/net/netfilter/nf_flow_table.h | 2 + net/netfilter/nf_flow_table_core.c | 66 +++++++++++++++++++++++++++ net/netfilter/nf_flow_table_ip.c | 6 +++ net/netfilter/nft_flow_offload.c | 3 ++ 4 files changed, 77 insertions(+)
Signature · 1 line
2.47.1
PATCH v2 1/3 netfilter: flow: Add bridge_vid member
Store the vid used on the bridge in the flow_offload_tuple, so it can be used later to identify fdb entries that relate to the tuple.
The bridge_vid member is added to the structures nft_forward_info, nf_flow_route and flow_offload_tuple. It can now be passed from net_device_path->bridge.vlan_id to flow_offload_tuple->out.bridge_vid.
--- include/net/netfilter/nf_flow_table.h | 2 ++ net/netfilter/nf_flow_table_core.c | 1 + net/netfilter/nft_flow_offload.c | 3 +++ 3 files changed, 6 insertions(+)
include/net/netfilter/nf_flow_table.h +2 -0
@@ -146,6 +146,7 @@ struct flow_offload_tuple {struct {u32 ifidx;u32 hw_ifidx; +u16 bridge_vid;u8 h_source[ETH_ALEN ];u8 h_dest[ETH_ALEN ]; } out;
@@ -212,6 +213,7 @@ struct nf_flow_route {struct {u32 ifindex;u32 hw_ifindex; +u16 bridge_vid;u8 h_source[ETH_ALEN ];u8 h_dest[ETH_ALEN ]; } out;
net/netfilter/nf_flow_table_core.c +1 -0
@@ -128,6 +128,7 @@ static int flow_offload_fill_route(struct flow_offload *flow, ETH_ALEN); flow_tuple->out.ifidx = route->tuple[dir].out.ifindex; flow_tuple->out.hw_ifidx = route->tuple[dir].out.hw_ifindex; + flow_tuple->out.bridge_vid = route->tuple[dir].out.bridge_vid;dst_release (dst);break ;case FLOW_OFFLOAD_XMIT_XFRM :
net/netfilter/nft_flow_offload.c +3 -0
@@ -85,6 +85,7 @@ struct nft_forward_info {__u16 id;__be16 proto; } encap[NF_FLOW_TABLE_ENCAP_MAX ]; +u16 bridge_vid;u8 num_encaps;u8 ingress_vlans;u8 h_source[ETH_ALEN ];
@@ -159,6 +160,7 @@ static void nft_dev_path_info(const struct net_device_path_stack *stack,case DEV_PATH_BR_VLAN_KEEP :break ; } + info->bridge_vid = path->bridge.vlan_id; info->xmit_type =FLOW_OFFLOAD_XMIT_DIRECT ;break ;default :
@@ -223,6 +225,7 @@ static void nft_dev_forward_path(struct nf_flow_route *route,memcpy (route->tuple[dir].out.h_dest, info.h_dest,ETH_ALEN ); route->tuple[dir].out.ifindex = info.outdev->ifindex; route->tuple[dir].out.hw_ifindex = info.hw_outdev->ifindex; + route->tuple[dir].out.bridge_vid = info.bridge_vid; route->tuple[dir].xmit_type = info.xmit_type; } }
Signature · 1 line
2.47.1
PATCH v2 2/3 netfilter: nf_flow_table_core: teardown direct xmit when destination changed
In reply to Eric WoudstraIn case of a bridge in the forward-fastpath or bridge-fastpath the fdb is used to create the tuple. In case of roaming at layer 2 level, for example 802.11r, the destination device is changed in the fdb. The destination device of a direct transmitting tuple is no longer valid and traffic is send to the wrong destination. Also the hardware offloaded fastpath is not valid anymore.
In case of roaming, a switchdev notification is send to delete the old fdb entry. Upon receiving this notification, mark all direct transmitting flows with the same ifindex, vid and hardware address as the fdb entry to be teared down. The hardware offloaded fastpath is still in effect, so minimize the delay of the work queue by setting the delay to zero.
--- net/netfilter/nf_flow_table_core.c | 65 ++++++++++++++++++++++++++++++ 1 file changed, 65 insertions(+)
net/netfilter/nf_flow_table_core.c +65 -0
@@ -13,6 +13,7 @@#include <net/netfilter/nf_conntrack_core.h> #include <net/netfilter/nf_conntrack_l4proto.h> #include <net/netfilter/nf_conntrack_tuple.h> +#include <net/switchdev.h> static DEFINE_MUTEX (flowtable_lock);static LIST_HEAD (flowtables);
@@ -743,6 +744,63 @@ void nf_flow_table_cleanup(struct net_device *dev) }EXPORT_SYMBOL_GPL (nf_flow_table_cleanup); +struct flow_cleanup_data { +const unsigned char *addr; +int ifindex; +u16 vid; +bool found; +}; + +static void nf_flow_table_do_cleanup_addr (struct nf_flowtable *flow_table, +struct flow_offload *flow,void *data) +{ +struct flow_cleanup_data *cud = data; + +if ((flow->tuplehash[0 ].tuple.xmit_type ==FLOW_OFFLOAD_XMIT_DIRECT && + flow->tuplehash[0 ].tuple.out.ifidx == cud->ifindex && + flow->tuplehash[0 ].tuple.out.bridge_vid == cud->vid && +ether_addr_equal (flow->tuplehash[0 ].tuple.out.h_dest, cud->addr)) || + (flow->tuplehash[1 ].tuple.xmit_type ==FLOW_OFFLOAD_XMIT_DIRECT && + flow->tuplehash[1 ].tuple.out.ifidx == cud->ifindex && + flow->tuplehash[1 ].tuple.out.bridge_vid == cud->vid && +ether_addr_equal (flow->tuplehash[1 ].tuple.out.h_dest, cud->addr))) { +flow_offload_teardown (flow); + cud->found = true; + } +} + +static int nf_flow_table_switchdev_event (struct notifier_block *unused, +unsigned long event,void *ptr) +{ +struct switchdev_notifier_fdb_info *fdb_info; +struct nf_flowtable *flowtable; +struct flow_cleanup_data cud; + +if (event !=SWITCHDEV_FDB_DEL_TO_DEVICE ) +return NOTIFY_DONE ; + + fdb_info = ptr; + cud.addr = fdb_info->addr; + cud.vid = fdb_info->vid; + cud.ifindex = fdb_info->info.dev->ifindex; + +mutex_lock (&flowtable_lock); +list_for_each_entry (flowtable, &flowtables, list) { + cud.found = false; +nf_flow_table_iterate (flowtable, nf_flow_table_do_cleanup_addr, &cud); +if (cud.found) +mod_delayed_work (system_power_efficient_wq, + &flowtable->gc_work,0 ); + } +mutex_unlock (&flowtable_lock); + +return NOTIFY_DONE ; +} + +struct notifier_block nf_flow_table_switchdev_nb__read_mostly = { + .notifier_call = nf_flow_table_switchdev_event, +}; +void nf_flow_table_free (struct nf_flowtable *flow_table) {mutex_lock (&flowtable_lock);
@@ -816,6 +874,10 @@ static int __init nf_flow_table_module_init(void)if (ret) goto out_offload; + ret =register_switchdev_notifier (&nf_flow_table_switchdev_nb); +if (ret <0 ) + goto out_sw_noti; + ret =nf_flow_register_bpf ();if (ret) goto out_bpf;
@@ -823,6 +885,8 @@ static int __init nf_flow_table_module_init(void)return 0 ; out_bpf: +unregister_switchdev_notifier (&nf_flow_table_switchdev_nb); +out_sw_noti:nf_flow_table_offload_exit (); out_offload:unregister_pernet_subsys (&nf_flow_table_net_ops);
@@ -831,6 +895,7 @@ static int __init nf_flow_table_module_init(void) static void __exit nf_flow_table_module_exit(void) { +unregister_switchdev_notifier (&nf_flow_table_switchdev_nb);nf_flow_table_offload_exit ();unregister_pernet_subsys (&nf_flow_table_net_ops); }
Signature · 1 line
2.47.1
Simon Horman
reviewerRe: [PATCH v2 nf-next 2/3] netfilter: nf_flow_table_core: teardown direct xmit when destination changed
Quoted 19 lines · Eric Woudstra
In case of a bridge in the forward-fastpath or bridge-fastpath the fdb is used to create the tuple. In case of roaming at layer 2 level, for example 802.11r, the destination device is changed in the fdb. The destination device of a direct transmitting tuple is no longer valid and traffic is send to the wrong destination. Also the hardware offloaded fastpath is not valid anymore.
In case of roaming, a switchdev notification is send to delete the old fdb entry. Upon receiving this notification, mark all direct transmitting flows with the same ifindex, vid and hardware address as the fdb entry to be teared down. The hardware offloaded fastpath is still in effect, so minimize the delay of the work queue by setting the delay to zero.
Signed-off-by Eric Woudstra <[email protected]>--- net/netfilter/nf_flow_table_core.c | 65 ++++++++++++++++++++++++++++++ 1 file changed, 65 insertions(+)net/netfilter/nf_flow_table_core.c +0
-0
...
net/netfilter/nf_flow_table_core.c void nf_flow_table_cleanup(struct net_device *dev) · line 802
Quoted 3 lines
net/netfilter/nf_flow_table_core.c +3
-0+struct notifier_block nf_flow_table_switchdev_nb__read_mostly = { + .notifier_call = nf_flow_table_switchdev_event, +};
Hi Eric,
A minor nit from my side:
nf_flow_table_switchdev_nb seems only be used in this file and if so it should be static.
Flagged by Sparse.
Quoted 35 lines
net/netfilter/nf_flow_table_core.c +8
-0+void nf_flow_table_free (struct nf_flowtable *flow_table) {mutex_lock (&flowtable_lock);@@ -816,6 +874,10 @@ static int __init nf_flow_table_module_init(void)if (ret) goto out_offload; + ret =register_switchdev_notifier (&nf_flow_table_switchdev_nb); +if (ret <0 ) + goto out_sw_noti; + ret =nf_flow_register_bpf ();if (ret) goto out_bpf;@@ -823,6 +885,8 @@ static int __init nf_flow_table_module_init(void)return 0 ; out_bpf: +unregister_switchdev_notifier (&nf_flow_table_switchdev_nb); +out_sw_noti:nf_flow_table_offload_exit (); out_offload:unregister_pernet_subsys (&nf_flow_table_net_ops);@@ -831,6 +895,7 @@ static int __init nf_flow_table_module_init(void) static void __exit nf_flow_table_module_exit(void) { +unregister_switchdev_notifier (&nf_flow_table_switchdev_nb);nf_flow_table_offload_exit ();unregister_pernet_subsys (&nf_flow_table_net_ops); }Signature · 1 line
2.47.1
PATCH v2 3/3 netfilter: nf_flow_table_ip: don't follow fastpath when marked teardown
In reply to Eric WoudstraWhen a flow is marked for teardown, because the destination is not valid any more, the software fastpath may still be in effect and traffic is still send to the wrong destination. Change the ip/ipv6 hooks to not use the software fastpath for a flow that is marked to be teared down and let the packet continue along the normal path.
--- net/netfilter/nf_flow_table_ip.c | 6 ++++++ 1 file changed, 6 insertions(+)
net/netfilter/nf_flow_table_ip.c +6 -0
@@ -542,6 +542,9 @@ nf_flow_offload_ip_hook(void *priv, struct sk_buff *skb, dir = tuplehash->tuple.dir; flow = container_of(tuplehash, struct flow_offload, tuplehash[dir]); +if (test_bit (NF_FLOW_TEARDOWN , &flow->flags)) +return NF_ACCEPT ; +switch (tuplehash->tuple.xmit_type) {case FLOW_OFFLOAD_XMIT_NEIGH : rt =dst_rtable (tuplehash->tuple.dst_cache);
@@ -838,6 +841,9 @@ nf_flow_offload_ipv6_hook(void *priv, struct sk_buff *skb, dir = tuplehash->tuple.dir; flow = container_of(tuplehash, struct flow_offload, tuplehash[dir]); +if (test_bit (NF_FLOW_TEARDOWN , &flow->flags)) +return NF_ACCEPT ; +switch (tuplehash->tuple.xmit_type) {case FLOW_OFFLOAD_XMIT_NEIGH : rt =dst_rt6_info (tuplehash->tuple.dst_cache);
Signature · 1 line
2.47.1
Quoted 20 lines · Eric Woudstra
In case of a bridge in the forward-fastpath or bridge-fastpath the fdb is used to create the tuple. In case of roaming at layer 2 level, for example 802.11r, the destination device is changed in the fdb. The destination device of a direct transmitting tuple is no longer valid and traffic is send to the wrong destination. Also the hardware offloaded fastpath is not valid anymore.
This flowentry needs to be torn down asap. Also make sure that the flow entry is not being used, when marked for teardown.
Changes in v2:
- Unchanged, only tags RFC net-next to PATCH nf-next.Eric Woudstra (3):
netfilter: flow: Addbridge_vidmember
netfilter:nf_flow_table_core: teardown direct xmit when destination
changed
netfilter:nf_flow_table_ip: don't follow fastpath when marked
teardown
Quoted 6 lines
include/net/netfilter/nf_flow_table.h | 2 + net/netfilter/nf_flow_table_core.c | 66 +++++++++++++++++++++++++++ net/netfilter/nf_flow_table_ip.c | 6 +++ net/netfilter/nft_flow_offload.c | 3 ++ 4 files changed, 77 insertions(+)
Hi Pablo,
I understand if you are busy, but this patch-set could be reviewed totally separate from my other submissions. It addresses the issue of L2 roaming for any fastpath.
I'll wait for any other comments, before sending the fix for 'static'.