x86/resctrl: Remove unappropriate references to cacheinfo in the resctrl subsystem.
Subsystems (2)
v4 cover x86/resctrl: Remove unappropriate references to cacheinfo in the resctrl subsystem.
V4:
- Add the tested by and reviewed by tags.
- Modify the commit log format.
V3:
- According to Reinette suggestion, modify the commit log description to make it easier for readers to understand
V2:
- Keep sanity checks in the __mon_event_count to ensure execution occurs exclusively on CPUs sharing the same L3 cache cluster
- When reading the top level event, obtain a CPU within hdr.cpu_mask. Then use the cacheinfo shared_cpu_map of this CPU instead of using hdr.cpu_mask directly
- Adjust code formatting and commit log descriptions.
In the resctrl subsystem's Sub-NUMA Cluster (SNC) mode, the rdt_mon_domain structure representing a NUMA node relies on the cacheinfo interface (rdt_mon_domain::ci) to store L3 cache information (e.g., shared_cpu_map) for monitoring. The L3 cache information of a SNC NUMA node determines which domains are summed for the "top level" L3-scoped events.
rdt_mon_domain::ci is initialized using the first online CPU of a NUMA node. When this CPU goes offline, its shared_cpu_map is cleared to contain only the offline CPU itself. Subsequently, attempting to read counters via smp_call_on_cpu(offline_cpu) fails (and error ignored), returning zero values for "top-level events" without any error indication. Replace the cacheinfo references in struct rdt_mon_domain and struct rmid_read with the cacheinfo ID (a unique identifier for the L3 cache).
rdt_domain_hdr::cpu_mask contains the online CPUs associated with that domain. When reading "top-level events", select a CPU from rdt_domain_hdr::cpu_mask and utilize its L3 shared_cpu_map to determine valid CPUs for reading RMID counter via the MSR interface.
Considering all CPUs associated with the L3 cache improves the chances of picking a housekeeping CPU on which the counter reading work can be queued, avoiding an unnecessary IPI.
Qinyun Tan (1):
x86/resctrl: Remove unappropriate references to cacheinfo in the
resctrl subsystem.
arch/x86/kernel/cpu/resctrl/core.c | 6 ++++-- fs/resctrl/ctrlmondata.c | 13 +++++++++---- fs/resctrl/internal.h | 4 ++-- fs/resctrl/monitor.c | 6 ++++-- fs/resctrl/rdtgroup.c | 6 +++--- include/linux/resctrl.h | 4 ++-- 6 files changed, 24 insertions(+), 15 deletions(-)
Signature · 1 line
2.43.5
PATCH v4 1/1 x86/resctrl: Remove unappropriate references to cacheinfo in the resctrl subsystem.
In the resctrl subsystem's Sub-NUMA Cluster (SNC) mode, the rdt_mon_domain structure representing a NUMA node relies on the cacheinfo interface (rdt_mon_domain::ci) to store L3 cache information (e.g., shared_cpu_map) for monitoring. The L3 cache information of a SNC NUMA node determines which domains are summed for the "top level" L3-scoped events.
rdt_mon_domain::ci is initialized using the first online CPU of a NUMA node. When this CPU goes offline, its shared_cpu_map is cleared to contain only the offline CPU itself. Subsequently, attempting to read counters via smp_call_on_cpu(offline_cpu) fails (and error ignored), returning zero values for "top-level events" without any error indication. Replace the cacheinfo references in struct rdt_mon_domain and struct rmid_read with the cacheinfo ID (a unique identifier for the L3 cache).
rdt_domain_hdr::cpu_mask contains the online CPUs associated with that domain. When reading "top-level events", select a CPU from rdt_domain_hdr::cpu_mask and utilize its L3 shared_cpu_map to determine valid CPUs for reading RMID counter via the MSR interface.
Considering all CPUs associated with the L3 cache improves the chances of picking a housekeeping CPU on which the counter reading work can be queued, avoiding an unnecessary IPI.
--- arch/x86/kernel/cpu/resctrl/core.c | 6 ++++-- fs/resctrl/ctrlmondata.c | 13 +++++++++---- fs/resctrl/internal.h | 4 ++-- fs/resctrl/monitor.c | 6 ++++-- fs/resctrl/rdtgroup.c | 6 +++--- include/linux/resctrl.h | 4 ++-- 6 files changed, 24 insertions(+), 15 deletions(-)
arch/x86/kernel/cpu/resctrl/core.c +4 -2
@@ -498,6 +498,7 @@ static void domain_add_cpu_mon(int cpu, struct rdt_resource *r)struct rdt_hw_mon_domain *hw_dom;struct rdt_domain_hdr *hdr;struct rdt_mon_domain *d; +struct cacheinfo *ci;int err;lockdep_assert_held (&domain_list_lock);
@@ -525,12 +526,13 @@ static void domain_add_cpu_mon(int cpu, struct rdt_resource *r) d = &hw_dom->d_resctrl; d->hdr.id = id; d->hdr.type =RESCTRL_MON_DOMAIN ; - d->ci =get_cpu_cacheinfo_level (cpu,RESCTRL_L3_CACHE ); -if (!d->ci) { + ci =get_cpu_cacheinfo_level (cpu,RESCTRL_L3_CACHE ); +if (!ci) {pr_warn_once ("Can't find L3 cache for CPU:%d resource %s\n" , cpu, r->name);mon_domain_free (hw_dom);return ; } + d->ci_id = ci->id;cpumask_set_cpu (cpu, &d->hdr.cpu_mask);arch_mon_domain_online (r, d);
fs/resctrl/ctrlmondata.c +9 -4
@@ -594,9 +594,10 @@ int rdtgroup_mondata_show(struct seq_file *m, void *arg)struct rmid_read rr = {0 };struct rdt_mon_domain *d;struct rdtgroup *rdtgrp; +int domid, cpu, ret =0 ;struct rdt_resource *r; +struct cacheinfo *ci;struct mon_data *md; -int domid, ret =0 ; rdtgrp =rdtgroup_kn_lock_live (of->kn);if (!rdtgrp) {
@@ -623,10 +624,14 @@ int rdtgroup_mondata_show(struct seq_file *m, void *arg)* one that matches this cache id. */ list_for_each_entry (d, &r->mon_domains, hdr.list) { -if (d->ci->id == domid) { - rr.ci = d->ci; +if (d->ci_id == domid) { + rr.ci_id = d->ci_id; + cpu =cpumask_any (&d->hdr.cpu_mask); + ci =get_cpu_cacheinfo_level (cpu,RESCTRL_L3_CACHE ); +if (!ci) +continue ;mon_event_read (&rr, r,NULL , rdtgrp, - &d->ci->shared_cpu_map, evtid, false); + &ci->shared_cpu_map, evtid, false); goto checkresult; } }
fs/resctrl/internal.h +2 -2
@@ -98,7 +98,7 @@ struct mon_data {* domains in @r sharing L3 @ci.id * @evtid: Which monitor event to read. * @first: Initialize MBM counter when true. -* @ci: Cacheinfo for L3. Only set when @d is NULL. Used when summing domains. +* @ci_id: Cacheinfo id for L3. Only set when @d is NULL. Used when summing domains. * @err: Error encountered when reading counter. * @val: Returned value of event counter. If @rgrp is a parent resource group, * @val includes the sum of event counts from its child resource groups.
@@ -112,7 +112,7 @@ struct rmid_read {struct rdt_mon_domain *d;enum resctrl_event_id evtid;bool first; -struct cacheinfo *ci; +unsigned int ci_id;int err;u64 val;void *arch_mon_ctx;
fs/resctrl/monitor.c +4 -2
@@ -361,6 +361,7 @@ static int __mon_event_count(u32 closid, u32 rmid, struct rmid_read *rr) {int cpu =smp_processor_id ();struct rdt_mon_domain *d; +struct cacheinfo *ci;struct mbm_state *m;int err, ret;u64 tval =0 ;
@@ -388,7 +389,8 @@ static int __mon_event_count(u32 closid, u32 rmid, struct rmid_read *rr) }/* Summing domains that share a cache, must be on a CPU for that cache. */ -if (!cpumask_test_cpu (cpu, &rr->ci->shared_cpu_map)) + ci =get_cpu_cacheinfo_level (cpu,RESCTRL_L3_CACHE ); +if (!ci || ci->id != rr->ci_id)return -EINVAL ;/*
@@ -400,7 +402,7 @@ static int __mon_event_count(u32 closid, u32 rmid, struct rmid_read *rr)*/ ret = -EINVAL ;list_for_each_entry (d, &rr->r->mon_domains, hdr.list) { -if (d->ci->id != rr->ci->id) +if (d->ci_id != rr->ci_id)continue ; err =resctrl_arch_rmid_read (rr->r, d, closid, rmid, rr->evtid, &tval, rr->arch_mon_ctx);
fs/resctrl/rdtgroup.c +3 -3
@@ -3034,7 +3034,7 @@ static void rmdir_mondata_subdir_allrdtgrp(struct rdt_resource *r,char name[32 ]; snc_mode = r->mon_scope ==RESCTRL_L3_NODE ; -sprintf (name,"mon_%s_%02d" , r->name, snc_mode ? d->ci->id : d->hdr.id); +sprintf (name,"mon_%s_%02d" , r->name, snc_mode ? d->ci_id : d->hdr.id);if (snc_mode)sprintf (subname,"mon_sub_%s_%02d" , r->name, d->hdr.id);
@@ -3059,7 +3059,7 @@ static int mon_add_all_files(struct kernfs_node *kn, struct rdt_mon_domain *d,return -EPERM ;list_for_each_entry (mevt, &r->evt_list, list) { - domid = do_sum ? d->ci->id : d->hdr.id; + domid = do_sum ? d->ci_id : d->hdr.id; priv =mon_get_kn_priv (r->rid, domid, mevt, do_sum);if (WARN_ON_ONCE (!priv))return -EINVAL ;
@@ -3087,7 +3087,7 @@ static int mkdir_mondata_subdir(struct kernfs_node *parent_kn,lockdep_assert_held (&rdtgroup_mutex); snc_mode = r->mon_scope ==RESCTRL_L3_NODE ; -sprintf (name,"mon_%s_%02d" , r->name, snc_mode ? d->ci->id : d->hdr.id); +sprintf (name,"mon_%s_%02d" , r->name, snc_mode ? d->ci_id : d->hdr.id); kn =kernfs_find_and_get (parent_kn, name);if (kn) {/*
include/linux/resctrl.h +2 -2
@@ -159,7 +159,7 @@ struct rdt_ctrl_domain {/** * struct rdt_mon_domain - group of CPUs sharing a resctrl monitor resource * @hdr: common header for different domain types -* @ci: cache info for this domain +* @ci_id: cache info id for this domain * @rmid_busy_llc: bitmap of which limbo RMIDs are above threshold * @mbm_total: saved state for MBM total bandwidth * @mbm_local: saved state for MBM local bandwidth
@@ -170,7 +170,7 @@ struct rdt_ctrl_domain {*/ struct rdt_mon_domain {struct rdt_domain_hdr hdr; -struct cacheinfo *ci; +unsigned int ci_id;unsigned long *rmid_busy_llc;struct mbm_state *mbm_total;struct mbm_state *mbm_local;
Signature · 1 line
2.43.5
Reinette Chatre
maintainerHi Qinyun Tan,
Quoted 11 lines · Qinyun Tan
In the resctrl subsystem's Sub-NUMA Cluster (SNC) mode, the
rdt_mon_domainstructure representing a NUMA node relies on the cacheinfo interface (rdt_mon_domain::ci) to store L3 cache information (e.g.,shared_cpu_map) for monitoring. The L3 cache information of a SNC NUMA node determines which domains are summed for the "top level" L3-scoped events.
rdt_mon_domain::ciis initialized using the first online CPU of a NUMA node. When this CPU goes offline, itsshared_cpu_mapis cleared to contain only the offline CPU itself. Subsequently, attempting to read counters viasmp_call_on_cpu(offline_cpu)fails (and error ignored), returning zero values for "top-level events" without any error indication. Replace
nit: the solution description starts with the word "Replace" above. It should be in a new paragraph to separate the solution description from the problem description.
Quoted 12 lines
the cacheinfo references in struct
rdt_mon_domainand structrmid_readwith the cacheinfo ID (a unique identifier for the L3 cache).
rdt_domain_hdr::cpu_maskcontains the online CPUs associated with that domain. When reading "top-level events", select a CPU fromrdt_domain_hdr::cpu_maskand utilize its L3shared_cpu_mapto determine valid CPUs for reading RMID counter via the MSR interface.Considering all CPUs associated with the L3 cache improves the chances of picking a housekeeping CPU on which the counter reading work can be queued, avoiding an unnecessary IPI.
Quoted 5 lines
Fixes 328ea68874642 ("x86/resctrl: Prepare for new Sub-NUMA Cluster (SNC) monitor files")Signed-off-by Qinyun Tan <[email protected]>Tested-by Tony Luck <[email protected]>Reviewed-by Reinette Chatre <[email protected]>---
Reinette
Hi Qinyun,
Ever since this resctrl subsystem has been refactored to support other architectures by moving common files related to filesystem handling into fs/resctrl/*, I have seen folks started to tag the subject line with "x86,fs/resctrl:" when patch touches files under fs/resctrl. Since your patches touches files under both arch/x86 and fs/resctrl/*, can you please accommodate this subject tag -> "x86,fs/resctrl:" so we are consistent.
/Anil
Quoted 204 lines · Qinyun Tan
In the resctrl subsystem's Sub-NUMA Cluster (SNC) mode, the
rdt_mon_domainstructure representing a NUMA node relies on the cacheinfo interface (rdt_mon_domain::ci) to store L3 cache information (e.g.,shared_cpu_map) for monitoring. The L3 cache information of a SNC NUMA node determines which domains are summed for the "top level" L3-scoped events.
rdt_mon_domain::ciis initialized using the first online CPU of a NUMA node. When this CPU goes offline, itsshared_cpu_mapis cleared to contain only the offline CPU itself. Subsequently, attempting to read counters viasmp_call_on_cpu(offline_cpu)fails (and error ignored), returning zero values for "top-level events" without any error indication. Replace the cacheinfo references in structrdt_mon_domainand structrmid_readwith the cacheinfo ID (a unique identifier for the L3 cache).
rdt_domain_hdr::cpu_maskcontains the online CPUs associated with that domain. When reading "top-level events", select a CPU fromrdt_domain_hdr::cpu_maskand utilize its L3shared_cpu_mapto determine valid CPUs for reading RMID counter via the MSR interface.Considering all CPUs associated with the L3 cache improves the chances of picking a housekeeping CPU on which the counter reading work can be queued, avoiding an unnecessary IPI.
Fixes 328ea68874642 ("x86/resctrl: Prepare for new Sub-NUMA Cluster (SNC) monitor files")Signed-off-by Qinyun Tan <[email protected]>Tested-by Tony Luck <[email protected]>Reviewed-by Reinette Chatre <[email protected]>--- arch/x86/kernel/cpu/resctrl/core.c | 6 ++++-- fs/resctrl/ctrlmondata.c | 13 +++++++++---- fs/resctrl/internal.h | 4 ++-- fs/resctrl/monitor.c | 6 ++++-- fs/resctrl/rdtgroup.c | 6 +++--- include/linux/resctrl.h | 4 ++-- 6 files changed, 24 insertions(+), 15 deletions(-)arch/x86/kernel/cpu/resctrl/core.c +4
-2@@ -498,6 +498,7 @@ static void domain_add_cpu_mon(int cpu, struct rdt_resource *r)struct rdt_hw_mon_domain *hw_dom;struct rdt_domain_hdr *hdr;struct rdt_mon_domain *d; +struct cacheinfo *ci;int err;lockdep_assert_held (&domain_list_lock);@@ -525,12 +526,13 @@ static void domain_add_cpu_mon(int cpu, struct rdt_resource *r) d = &hw_dom->d_resctrl; d->hdr.id = id; d->hdr.type =RESCTRL_MON_DOMAIN ; - d->ci =get_cpu_cacheinfo_level (cpu,RESCTRL_L3_CACHE ); -if (!d->ci) { + ci =get_cpu_cacheinfo_level (cpu,RESCTRL_L3_CACHE ); +if (!ci) {pr_warn_once ("Can't find L3 cache for CPU:%d resource %s\n" , cpu, r->name);mon_domain_free (hw_dom);return ; } + d->ci_id = ci->id;cpumask_set_cpu (cpu, &d->hdr.cpu_mask);arch_mon_domain_online (r, d);fs/resctrl/ctrlmondata.c +9
-4@@ -594,9 +594,10 @@ int rdtgroup_mondata_show(struct seq_file *m, void *arg)struct rmid_read rr = {0 };struct rdt_mon_domain *d;struct rdtgroup *rdtgrp; +int domid, cpu, ret =0 ;struct rdt_resource *r; +struct cacheinfo *ci;struct mon_data *md; -int domid, ret =0 ; rdtgrp =rdtgroup_kn_lock_live (of->kn);if (!rdtgrp) {@@ -623,10 +624,14 @@ int rdtgroup_mondata_show(struct seq_file *m, void *arg)* one that matches this cache id. */ list_for_each_entry (d, &r->mon_domains, hdr.list) { -if (d->ci->id == domid) { - rr.ci = d->ci; +if (d->ci_id == domid) { + rr.ci_id = d->ci_id; + cpu =cpumask_any (&d->hdr.cpu_mask); + ci =get_cpu_cacheinfo_level (cpu,RESCTRL_L3_CACHE ); +if (!ci) +continue ;mon_event_read (&rr, r,NULL , rdtgrp, - &d->ci->shared_cpu_map, evtid, false); + &ci->shared_cpu_map, evtid, false); goto checkresult; } }fs/resctrl/internal.h +2
-2@@ -98,7 +98,7 @@ struct mon_data {* domains in @r sharing L3 @ci.id * @evtid: Which monitor event to read. * @first: Initialize MBM counter when true. -* @ci: Cacheinfo for L3. Only set when @d is NULL. Used when summing domains. +* @ci_id: Cacheinfo id for L3. Only set when @d is NULL. Used when summing domains. * @err: Error encountered when reading counter. * @val: Returned value of event counter. If @rgrp is a parent resource group, * @val includes the sum of event counts from its child resource groups. @@ -112,7 +112,7 @@ struct rmid_read {struct rdt_mon_domain *d;enum resctrl_event_id evtid;bool first; -struct cacheinfo *ci; +unsigned int ci_id;int err;u64 val;void *arch_mon_ctx;fs/resctrl/monitor.c +4
-2@@ -361,6 +361,7 @@ static int __mon_event_count(u32 closid, u32 rmid, struct rmid_read *rr) {int cpu =smp_processor_id ();struct rdt_mon_domain *d; +struct cacheinfo *ci;struct mbm_state *m;int err, ret;u64 tval =0 ;@@ -388,7 +389,8 @@ static int __mon_event_count(u32 closid, u32 rmid, struct rmid_read *rr) }/* Summing domains that share a cache, must be on a CPU for that cache. */ -if (!cpumask_test_cpu (cpu, &rr->ci->shared_cpu_map)) + ci =get_cpu_cacheinfo_level (cpu,RESCTRL_L3_CACHE ); +if (!ci || ci->id != rr->ci_id)return -EINVAL ;/* @@ -400,7 +402,7 @@ static int __mon_event_count(u32 closid, u32 rmid, struct rmid_read *rr)*/ ret = -EINVAL ;list_for_each_entry (d, &rr->r->mon_domains, hdr.list) { -if (d->ci->id != rr->ci->id) +if (d->ci_id != rr->ci_id)continue ; err =resctrl_arch_rmid_read (rr->r, d, closid, rmid, rr->evtid, &tval, rr->arch_mon_ctx);fs/resctrl/rdtgroup.c +3
-3@@ -3034,7 +3034,7 @@ static void rmdir_mondata_subdir_allrdtgrp(struct rdt_resource *r,char name[32 ]; snc_mode = r->mon_scope ==RESCTRL_L3_NODE ; -sprintf (name,"mon_%s_%02d" , r->name, snc_mode ? d->ci->id : d->hdr.id); +sprintf (name,"mon_%s_%02d" , r->name, snc_mode ? d->ci_id : d->hdr.id);if (snc_mode)sprintf (subname,"mon_sub_%s_%02d" , r->name, d->hdr.id);@@ -3059,7 +3059,7 @@ static int mon_add_all_files(struct kernfs_node *kn, struct rdt_mon_domain *d,return -EPERM ;list_for_each_entry (mevt, &r->evt_list, list) { - domid = do_sum ? d->ci->id : d->hdr.id; + domid = do_sum ? d->ci_id : d->hdr.id; priv =mon_get_kn_priv (r->rid, domid, mevt, do_sum);if (WARN_ON_ONCE (!priv))return -EINVAL ;@@ -3087,7 +3087,7 @@ static int mkdir_mondata_subdir(struct kernfs_node *parent_kn,lockdep_assert_held (&rdtgroup_mutex); snc_mode = r->mon_scope ==RESCTRL_L3_NODE ; -sprintf (name,"mon_%s_%02d" , r->name, snc_mode ? d->ci->id : d->hdr.id); +sprintf (name,"mon_%s_%02d" , r->name, snc_mode ? d->ci_id : d->hdr.id); kn =kernfs_find_and_get (parent_kn, name);if (kn) {/* include/linux/resctrl.h +2
-2@@ -159,7 +159,7 @@ struct rdt_ctrl_domain {/** * struct rdt_mon_domain - group of CPUs sharing a resctrl monitor resource * @hdr: common header for different domain types -* @ci: cache info for this domain +* @ci_id: cache info id for this domain * @rmid_busy_llc: bitmap of which limbo RMIDs are above threshold * @mbm_total: saved state for MBM total bandwidth * @mbm_local: saved state for MBM local bandwidth @@ -170,7 +170,7 @@ struct rdt_ctrl_domain {*/ struct rdt_mon_domain {struct rdt_domain_hdr hdr; -struct cacheinfo *ci; +unsigned int ci_id;unsigned long *rmid_busy_llc;struct mbm_state *mbm_total;struct mbm_state *mbm_local;
Hi, Keshavamurthy, Anil S:
Ok, This suggestion is very reasonable. A few seconds before receiving your email, I have sent the Patch of version 5, so just let me send the Patch of version 6 again :).
Quoted 218 lines · Anil S
Hi Qinyun,
Ever since this resctrl subsystem has been refactored to support other architectures by moving common files related to filesystem handling into
fs/resctrl/*, I have seen folks started to tag the subject line with "x86,fs/resctrl:" when patch touches files under fs/resctrl. Since your patches touches files under botharch/x86andfs/resctrl/*, can you please accommodate this subject tag -> "x86,fs/resctrl:" so we are consistent./Anil
Quoted 211 lines · Qinyun Tan
In the resctrl subsystem's Sub-NUMA Cluster (SNC) mode, the
rdt_mon_domainstructure representing a NUMA node relies on the cacheinfo interface (rdt_mon_domain::ci) to store L3 cache information (e.g.,shared_cpu_map) for monitoring. The L3 cache information of a SNC NUMA node determines which domains are summed for the "top level" L3-scoped events.
rdt_mon_domain::ciis initialized using the first online CPU of a NUMA node. When this CPU goes offline, itsshared_cpu_mapis cleared to contain only the offline CPU itself. Subsequently, attempting to read counters viasmp_call_on_cpu(offline_cpu)fails (and error ignored), returning zero values for "top-level events" without any error indication. Replace the cacheinfo references in structrdt_mon_domainand structrmid_readwith the cacheinfo ID (a unique identifier for the L3 cache).
rdt_domain_hdr::cpu_maskcontains the online CPUs associated with that domain. When reading "top-level events", select a CPU fromrdt_domain_hdr::cpu_maskand utilize its L3shared_cpu_mapto determine valid CPUs for reading RMID counter via the MSR interface.Considering all CPUs associated with the L3 cache improves the chances of picking a housekeeping CPU on which the counter reading work can be queued, avoiding an unnecessary IPI.
Fixes 328ea68874642 ("x86/resctrl: Prepare for new Sub-NUMA Cluster (SNC) monitor files")Signed-off-by Qinyun Tan <[email protected]>Tested-by Tony Luck <[email protected]>Reviewed-by Reinette Chatre <[email protected]>---
arch/x86/kernel/cpu/resctrl/core.c| 6 ++++-- fs/resctrl/ctrlmondata.c | 13 +++++++++---- fs/resctrl/internal.h | 4 ++-- fs/resctrl/monitor.c | 6 ++++-- fs/resctrl/rdtgroup.c | 6 +++--- include/linux/resctrl.h | 4 ++--6 files changed, 24 insertions(+), 15 deletions(-)arch/x86/kernel/cpu/resctrl/core.c +4
-2@@ -498,6 +498,7 @@ static void domain_add_cpu_mon(int cpu, struct rdt_resource *r) struct rdt_hw_mon_domain *hw_dom; struct rdt_domain_hdr *hdr; struct rdt_mon_domain *d; + struct cacheinfo *ci; int err; lockdep_assert_held(&domain_list_lock);@@ -525,12 +526,13 @@ static void domain_add_cpu_mon(int cpu, struct rdt_resource *r) d = &hw_dom->d_resctrl; d->hdr.id = id; d->hdr.type = RESCTRL_MON_DOMAIN; - d->ci = get_cpu_cacheinfo_level(cpu, RESCTRL_L3_CACHE); - if (!d->ci) { + ci = get_cpu_cacheinfo_level(cpu, RESCTRL_L3_CACHE); + if (!ci) { pr_warn_once("Can't find L3 cache for CPU:%d resource %s\n", cpu, r->name); mon_domain_free(hw_dom); return; } + d->ci_id = ci->id; cpumask_set_cpu(cpu, &d->hdr.cpu_mask); arch_mon_domain_online(r, d);fs/resctrl/ctrlmondata.c +9
-4@@ -594,9 +594,10 @@ int rdtgroup_mondata_show(struct seq_file *m, void *arg) struct rmid_read rr = {0}; struct rdt_mon_domain *d; struct rdtgroup *rdtgrp; + int domid, cpu, ret = 0; struct rdt_resource *r; + struct cacheinfo *ci; struct mon_data *md; - int domid, ret = 0; rdtgrp = rdtgroup_kn_lock_live(of->kn); if (!rdtgrp) {@@ -623,10 +624,14 @@ int rdtgroup_mondata_show(struct seq_file *m,void *arg) * one that matches this cache id. */ list_for_each_entry(d, &r->mon_domains, hdr.list) { - if (d->ci->id == domid) { - rr.ci = d->ci; + if (d->ci_id == domid) { + rr.ci_id = d->ci_id; + cpu = cpumask_any(&d->hdr.cpu_mask); + ci = get_cpu_cacheinfo_level(cpu, RESCTRL_L3_CACHE); + if (!ci) + continue; mon_event_read(&rr, r, NULL, rdtgrp, - &d->ci->shared_cpu_map, evtid, false); + &ci->shared_cpu_map, evtid, false); goto checkresult; }}
fs/resctrl/internal.h +0
-1@@ -98,7 +98,7 @@ struct mon_data { * domains in @r sharing L3 @ci.id * @evtid: Which monitor event to read. * @first: Initialize MBM counter when true. - * @ci: Cacheinfo for L3. Only set when @d is NULL. Used whensumming domains.
+ * @ci_id: Cacheinfo id for L3. Only set when @d is NULL. Used when summing domains.
* @err: Error encountered when reading counter.
* @val: Returned value of event counter. If @rgrp is a parent resource group, * @val includes the sum of event counts from its child resource groups.fs/resctrl/internal.h +1
-1@@ -112,7 +112,7 @@ struct rmid_read { struct rdt_mon_domain *d; enum resctrl_event_id evtid; bool first; - struct cacheinfo *ci; + unsigned int ci_id; int err; u64 val; void *arch_mon_ctx;fs/resctrl/monitor.c +1
-0@@ -361,6 +361,7 @@ static int __mon_event_count(u32 closid, u32 rmid, struct rmid_read *rr) { int cpu = smp_processor_id(); struct rdt_mon_domain *d; + struct cacheinfo *ci; struct mbm_state *m; int err, ret;u64 tval = 0;
fs/resctrl/monitor.c +3
-2@@ -388,7 +389,8 @@ static int __mon_event_count(u32 closid, u32 rmid, struct rmid_read *rr) } /* Summing domains that share a cache, must be on a CPU for that cache. */ - if (!cpumask_test_cpu(cpu, &rr->ci->shared_cpu_map)) + ci = get_cpu_cacheinfo_level(cpu, RESCTRL_L3_CACHE); + if (!ci || ci->id != rr->ci_id) return -EINVAL; /*@@ -400,7 +402,7 @@ static int __mon_event_count(u32 closid, u32 rmid,struct rmid_read *rr) */ ret = -EINVAL; list_for_each_entry(d, &rr->r->mon_domains, hdr.list) { - if (d->ci->id != rr->ci->id) + if (d->ci_id != rr->ci_id) continue; err = resctrl_arch_rmid_read(rr->r, d, closid, rmid,
rr->evtid, &tval,rr->arch_mon_ctx);fs/resctrl/rdtgroup.c +1
-1@@ -3034,7 +3034,7 @@ static void rmdir_mondata_subdir_allrdtgrp(struct rdt_resource *r, char name[32]; snc_mode = r->mon_scope == RESCTRL_L3_NODE; - sprintf(name, "mon_%s_%02d", r->name, snc_mode ? d->ci->id : d- >hdr.id); + sprintf(name, "mon_%s_%02d", r->name, snc_mode ? d->ci_id : d- >hdr.id); if (snc_mode)
sprintf(subname, "mon_sub_%s_%02d", r->name, d->hdr.id);fs/resctrl/rdtgroup.c +2
-2@@ -3059,7 +3059,7 @@ static int mon_add_all_files(struct kernfs_node *kn, struct rdt_mon_domain *d, return -EPERM; list_for_each_entry(mevt, &r->evt_list, list) { - domid = do_sum ? d->ci->id : d->hdr.id; + domid = do_sum ? d->ci_id : d->hdr.id; priv = mon_get_kn_priv(r->rid, domid, mevt, do_sum); if (WARN_ON_ONCE(!priv)) return -EINVAL;@@ -3087,7 +3087,7 @@ static int mkdir_mondata_subdir(structkernfs_node *parent_kn, lockdep_assert_held(&rdtgroup_mutex); snc_mode = r->mon_scope == RESCTRL_L3_NODE; - sprintf(name, "mon_%s_%02d", r->name, snc_mode ? d->ci->id : d- >hdr.id); + sprintf(name, "mon_%s_%02d", r->name, snc_mode ? d->ci_id : d- >hdr.id); kn = kernfs_find_and_get(parent_kn, name);if (kn) {
/*include/linux/resctrl.h +2
-2@@ -159,7 +159,7 @@ struct rdt_ctrl_domain { /*** struct rdt_mon_domain - group of CPUs sharing a resctrl monitor resource * @hdr: common header for different domain types -* @ci: cache info for this domain +* @ci_id: cache info id for this domain * @rmid_busy_llc: bitmap of which limbo RMIDs are above threshold * @mbm_total: saved state for MBM total bandwidth * @mbm_local: saved state for MBM local bandwidth @@ -170,7 +170,7 @@ struct rdt_ctrl_domain {*/ struct rdt_mon_domain { struct rdt_domain_hdr hdr; - struct cacheinfo *ci; + unsigned int ci_id; unsigned long *rmid_busy_llc; struct mbm_state *mbm_total; struct mbm_state *mbm_local;