board: phytec: phytec_som_detection: Add missing assignment
PATCH v2 1/2 board: phytec: phytec_som_detection: Add missing assignment
Assign the return value of snprintf (total length) to a variable to properly check if the string has the correct length.
Currently, this variable is always zero and the length check after snprintf will always fail.
---
No changes between v1 and v2.
board/phytec/common/phytec_som_detection.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
board/phytec/common/phytec_som_detection.c +2 -2
@@ -346,8 +346,8 @@ static int phytec_get_part_number(struct phytec_eeprom_data *data,return 0 ; }if (api2->som_type <=3 ) { -snprintf (part,PHYTEC_PART_NUMBER_MAX_LEN +1 ,"%s.%s" , - product_name, api2->bom_rev); + len =snprintf (part,PHYTEC_PART_NUMBER_MAX_LEN +1 ,"%s.%s" , + product_name, api2->bom_rev);if (len !=PHYTEC_PART_NUMBER_KSP_LEN )return -EINVAL ;return 0 ;
Signature · 1 line
2.25.1
PATCH v2 2/2 board: phytec: phytec_som_detection: Add support for phyFLEX
phyFLEX are SoMs based on the FPSC standard.
Add additional "SOM types" for the phyFLEX modules base on the FPSC Gamma specification. These modules come in four different variants; prototypes (PT), standard product (SP), KSP (KP) and KSM (KM).
---
Changes in v2:
Fixed three spelling errors.
"addition" -> "additional"
"specifiction" -> "specification"
"differnt" -> "different"
board/phytec/common/phytec_som_detection.c | 38 ++++++++++++++++++++-- board/phytec/common/phytec_som_detection.h | 8 +++-- 2 files changed, 41 insertions(+), 5 deletions(-)
board/phytec/common/phytec_som_detection.c +35 -3
@@ -308,14 +308,24 @@ static int phytec_get_product_name(struct phytec_eeprom_data *data,case 7 : som_type =1 ;break ; +case 8 : +case 9 : +case 10 : +case 11 : + som_type =SOM_TYPE_PFL_G ; +break ;default :pr_err ("%s: Invalid SOM type: %i\n" , __func__, api2->som_type);return -EINVAL ; }; - len =snprintf (product,PHYTEC_PRODUCT_NAME_MAX_LEN +1 ,"%s-%03u" , +const char *fmt = (som_type ==SOM_TYPE_PFL_G ) ?"%s-%02u" :"%s-%03u" ; + + len =snprintf (product,PHYTEC_PRODUCT_NAME_MAX_LEN +1 , fmt, phytec_som_type_str[som_type], api2->som_no); -if (len !=PHYTEC_PRODUCT_NAME_STD_LEN ) +if (som_type !=SOM_TYPE_PFL_G && len !=PHYTEC_PRODUCT_NAME_PCX_LEN ) +return -EINVAL ; +if (som_type ==SOM_TYPE_PFL_G && len !=PHYTEC_PRODUCT_NAME_PFL_LEN )return -EINVAL ;return 0 ; }
@@ -327,6 +337,7 @@ static int phytec_get_part_number(struct phytec_eeprom_data *data,struct phytec_api2_data *api2;unsigned int ksp_type;int res, len; +char *variant ="SP" ;if (!data->valid || data->payload.api_rev <PHYTEC_API_REV2 )return -EINVAL ;
@@ -341,7 +352,7 @@ static int phytec_get_part_number(struct phytec_eeprom_data *data, len =snprintf (part,PHYTEC_PART_NUMBER_MAX_LEN +1 ,"%s-%s.%s" , product_name, api2->opt, api2->bom_rev); -if (len <PHYTEC_PART_NUMBER_STD_LEN ) +if (len <PHYTEC_PART_NUMBER_PCX_LEN )return -EINVAL ;return 0 ; }
@@ -353,6 +364,27 @@ static int phytec_get_part_number(struct phytec_eeprom_data *data,return 0 ; } +if (api2->som_type >=8 && api2->som_type <=11 ) { +switch (api2->som_type) { +case 8 : + variant ="PT" ; +break ; +case 10 : + variant ="KP" ; +break ; +case 11 : + variant ="KM" ; +break ; + } + + len =snprintf (part,PHYTEC_PART_NUMBER_MAX_LEN +1 , +"%s-%s%03u.%s" , product_name, variant, + api2->ksp_no, api2->bom_rev); +if (len !=PHYTEC_PART_NUMBER_PFL_LEN ) +return -EINVAL ; +return 0 ; + } +switch (api2->som_type) {case 4 : ksp_type =3 ;
board/phytec/common/phytec_som_detection.h +6 -2
@@ -18,10 +18,12 @@#define PHYTEC_GET_OPTION (option) \ (((option) > '9') ? (option) - 'A' + 10 : (option) - '0') -#define PHYTEC_PRODUCT_NAME_STD_LEN 7 // PCx-000 +#define PHYTEC_PRODUCT_NAME_PCX_LEN 7 // PCx-000 +#define PHYTEC_PRODUCT_NAME_PFL_LEN 8 // PFL-x-00#define PHYTEC_PRODUCT_NAME_KSP_LEN 8 // KSP-0000#define PHYTEC_PRODUCT_NAME_MAX_LEN PHYTEC_PRODUCT_NAME_KSP_LEN -#define PHYTEC_PART_NUMBER_STD_LEN 11 // PCx-000-\w{1,17}.Ax +#define PHYTEC_PART_NUMBER_PCX_LEN 11 // PCx-000-\w{1,17}.Ax +#define PHYTEC_PART_NUMBER_PFL_LEN 17 // PFL-x-00-xx000.Ax#define PHYTEC_PART_NUMBER_KSP_LEN 11 // KSP-0000.Ax#define PHYTEC_PART_NUMBER_STD_KSP_LEN 16 // PCx-000-KSx00.Ax#define PHYTEC_PART_NUMBER_MAX_LEN PHYTEC_PRODUCT_NAME_MAX_LEN + 21
@@ -38,6 +40,7 @@ enum phytec_som_type_str {SOM_TYPE_PCL ,SOM_TYPE_KSM ,SOM_TYPE_KSP , + SOM_TYPE_PFL_G, }; static const char * const phytec_som_type_str[] = {
@@ -45,6 +48,7 @@ static const char * const phytec_som_type_str[] = {"PCL" ,"KSM" ,"KSP" , + "PFL-G", }; struct phytec_api0_data {
Signature · 1 line
2.25.1
Quoted 8 lines · Daniel Schultz
Assign the return value of snprintf (total length) to a variable to properly check if the string has the correct length.
Currently, this variable is always zero and the length check after snprintf will always fail.
[...]
Applied to u-boot/next, thanks!
[1/2] board: phytec: phytec_som_detection: Add missing assignment
commit: 9ce3d264e3b79b91d997eaa89dcd51488259c2b9
[2/2] board: phytec: phytec_som_detection: Add support for phyFLEX
commit: 7bcf0160901970f4417488982199fece129567b4Signature · 1 line
Tom