scsi: docs: Add description for missing options of link_power_management_policy
PATCH v2 1/1 scsi: docs: Add description for missing options of link_power_management_policy
With the kernel update we have more different policy for SCSI link power management. Add the corresponding description to the file.
Signed-off-by Yiwei Lin <[email protected]>
--- .../scsi/link_power_management_policy.rst | 23 ++++++++++++++----- 1 file changed, 17 insertions(+), 6 deletions(-)
Documentation/scsi/link_power_management_policy.rst +17 -6
@@ -5,13 +5,13 @@ Link Power Managent Policy ========================== This parameter allows the user to set the link (interface) power management. -There are 3 possible options: +There are 6 possible options: -===================== ===================================================== +====================== ===================================================== Value Effect -===================== ===================================================== -min_power Tell the controller to try to make the link use the - least possible power when possible. This may +====================== ===================================================== +min_power Enable slumber mode(no partial mode) for the link to + use the least possible power when possible. This may sacrifice some performance due to increased latency when coming out of lower power states.
@@ -22,4 +22,15 @@ max_performance Generally, this means no power management. Tell medium_power Tell the controller to enter a lower power state when possible, but do not enter the lowest power state, thus improving latency over min_power setting. -===================== ===================================================== + +keep_firmware_settings Do not change the current firmware settings for + Power management. This is the default setting. + +med_power_with_dipm Same as medium_power, but additionally with + Device-initiated power management(DIPM) enabled, + as Intel Rapid Storage Technology(IRST) does. + +min_power_with_partial Same as min_power, but additionally with partial + power state enabled, which may improve performance + over min_power setting. +====================== =====================================================
Signature · 1 line
2.34.1
Quoted 5 lines · Yiwei Lin
With the kernel update we have more different policy for SCSI link power management. Add the corresponding description to the file.
Signed-off-by Yiwei Lin <[email protected]>
Tested-by Randy Dunlap <[email protected]>
Thanks.
Quoted 44 lines
--- .../scsi/link_power_management_policy.rst | 23 ++++++++++++++----- 1 file changed, 17 insertions(+), 6 deletions(-)Documentation/scsi/link_power_management_policy.rst +17
-6@@ -5,13 +5,13 @@ Link Power Managent Policy ========================== This parameter allows the user to set the link (interface) power management. -There are 3 possible options: +There are 6 possible options: -===================== ===================================================== +====================== ===================================================== Value Effect -===================== ===================================================== -min_power Tell the controller to try to make the link use the - least possible power when possible. This may +====================== ===================================================== +min_power Enable slumber mode(no partial mode) for the link to + use the least possible power when possible. This may sacrifice some performance due to increased latency when coming out of lower power states.@@ -22,4 +22,15 @@ max_performance Generally, this means no power management. Tell medium_power Tell the controller to enter a lower power state when possible, but do not enter the lowest power state, thus improving latency over min_power setting. -===================== ===================================================== + +keep_firmware_settings Do not change the current firmware settings for + Power management. This is the default setting. + +med_power_with_dipm Same as medium_power, but additionally with + Device-initiated power management(DIPM) enabled, + as Intel Rapid Storage Technology(IRST) does. + +min_power_with_partial Same as min_power, but additionally with partial + power state enabled, which may improve performance + over min_power setting. +====================== =====================================================
Signature · 1 line
~Randy
Quoted 8 lines · Yiwei Lin
With the kernel update we have more different policy for SCSI link power management. Add the corresponding description to the file.
Signed-off-by Yiwei Lin <[email protected]>--- .../scsi/link_power_management_policy.rst | 23 ++++++++++++++----- 1 file changed, 17 insertions(+), 6 deletions(-)
Applied, thanks.
jon