rtc: ds1390: fix number of bytes read from RTC

PATCH New Andreas Gabriel-Platschek 1 participant 1 message Feb 9 Real time clock (RTC)

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 rtc: ds1390: fix number of bytes read from RTC

The spi_write_then_read() reads 8 bytes starting from DS1390_REG_SECONDS (== 0x01), so the last byte read would already be part of the alarm (Tenths and Hundredths of Seconds) feature.

However 7 bytes are engouh -- seconds (0x01), minutes (0x02), hours (0x03), day (0x04), date (0x05), month/century (0x06) and year (0x07).

---
 drivers/rtc/rtc-ds1390.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/rtc/rtc-ds1390.c +1 -1
index f46428ca77cc..f7afd6bdeb4a 100644
@@ -134,7 +134,7 @@ static int ds1390_read_time(struct device *dev, struct rtc_time *dt)
 	chip->txrx_buf[0] = DS1390_REG_SECONDS;
 
 	/* do the i/o */
-	status = spi_write_then_read(spi, chip->txrx_buf, 1, chip->txrx_buf, 8);
+	status = spi_write_then_read(spi, chip->txrx_buf, 1, chip->txrx_buf, 7);
 	if (status != 0)
 		return status;
 
Signature · 1 line
2.47.3