rtc: ds1390: fix number of bytes read from RTC
PATCH 1/1 rtc: ds1390: fix number of bytes read from RTC
The spi_write_then_read() reads 8 bytes starting from DS1390_REG_SECONDS (== 0x01), so the last byte read would already be part of the alarm (Tenths and Hundredths of Seconds) feature.
However 7 bytes are engouh -- seconds (0x01), minutes (0x02), hours (0x03), day (0x04), date (0x05), month/century (0x06) and year (0x07).
Signed-off-by Andreas Gabriel-Platschek <[email protected]>
--- drivers/rtc/rtc-ds1390.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/rtc/rtc-ds1390.c +1 -1
@@ -134,7 +134,7 @@ static int ds1390_read_time(struct device *dev, struct rtc_time *dt) chip->txrx_buf[0 ] =DS1390_REG_SECONDS ;/* do the i/o */ - status =spi_write_then_read (spi, chip->txrx_buf,1 , chip->txrx_buf,8 ); + status =spi_write_then_read (spi, chip->txrx_buf,1 , chip->txrx_buf,7 );if (status !=0 )return status;
Signature · 1 line