phy: qcom: qmp-combo: Move pipe_clk on/off to common
Subsystems (2)
PATCH v3 1/1 phy: qcom: qmp-combo: Move pipe_clk on/off to common
Keep the USB pipe clock working when the phy is in DP-only mode, because the dwc controller still needs it for USB 2.0 over the same Type-C port.
Tested with the BenQ RD280UA monitor which has a downstream-facing port for data passthrough that's manually switchable between USB 2 and 3, corresponding to 4-lane and 2-lane DP respectively.
Note: the suspend/resume callbacks were already gating the enable/disable of this clock only on init_count and not usb_init_count!
---
v3: Pull suggestion/fix and R-b
v2: https://lore.kernel.org/all/[email protected]/
--- drivers/phy/qualcomm/phy-qcom-qmp-combo.c | 18 ++++++++++-------- 1 file changed, 10 insertions(+), 8 deletions(-)
drivers/phy/qualcomm/phy-qcom-qmp-combo.c +10 -8
@@ -3691,6 +3691,13 @@ static int qmp_combo_com_init(struct qmp_combo *qmp, bool force)if (ret) goto err_assert_reset; +/* In DP-only mode, the pipe clk is still required for USB2 */ + ret =clk_prepare_enable (qmp->pipe_clk); +if (ret) { +dev_err (qmp->dev,"pipe_clk enable failed err=%d\n" , ret); + goto err_disable_clocks; + } +qphy_setbits (com,QPHY_V3_DP_COM_POWER_DOWN_CTRL ,SW_PWRDN );/* override hardware control for reset of qmp phy */
@@ -3749,6 +3756,8 @@ static int qmp_combo_com_init(struct qmp_combo *qmp, bool force)return 0 ; +err_disable_clocks: +clk_bulk_disable_unprepare (qmp->num_clks, qmp->clks); err_assert_reset:reset_control_bulk_assert (cfg->num_resets, qmp->resets); err_disable_regulators:
@@ -3768,6 +3777,7 @@ static int qmp_combo_com_exit(struct qmp_combo *qmp, bool force)reset_control_bulk_assert (cfg->num_resets, qmp->resets); +clk_disable_unprepare (qmp->pipe_clk);clk_bulk_disable_unprepare (qmp->num_clks, qmp->clks);regulator_bulk_disable (cfg->num_vregs, qmp->vregs);
@@ -3871,12 +3881,6 @@ static int qmp_combo_usb_power_on(struct phy *phy)qmp_configure (qmp->dev, serdes, cfg->serdes_tbl, cfg->serdes_tbl_num); - ret =clk_prepare_enable (qmp->pipe_clk); -if (ret) { -dev_err (qmp->dev,"pipe_clk enable failed err=%d\n" , ret); -return ret; - } -/* Tx, Rx, and PCS configurations */ qmp_configure_lane (qmp->dev, tx, cfg->tx_tbl, cfg->tx_tbl_num,1 );qmp_configure_lane (qmp->dev, tx2, cfg->tx_tbl, cfg->tx_tbl_num,2 );
@@ -3922,8 +3926,6 @@ static int qmp_combo_usb_power_off(struct phy *phy)struct qmp_combo *qmp =phy_get_drvdata (phy);const struct qmp_phy_cfg *cfg = qmp->cfg; -clk_disable_unprepare (qmp->pipe_clk); -/* PHY reset */ qphy_setbits (qmp->pcs, cfg->regs[QPHY_SW_RESET ],SW_RESET );
Signature · 1 line
2.52.0
Quoted 8 lines · Val Packett
Keep the USB pipe clock working when the phy is in DP-only mode, because the dwc controller still needs it for USB 2.0 over the same Type-C port.
Tested with the BenQ RD280UA monitor which has a downstream-facing port for data passthrough that's manually switchable between USB 2 and 3, corresponding to 4-lane and 2-lane DP respectively.
[...]
Applied, thanks!
[1/1] phy: qcom: qmp-combo: Move pipe_clk on/off to common
commit: f546912bcac6463a22c5825e27a7952f8b48c887
Best regards,
Signature · 1 line
~Vinod