xen/uart: set a default baudrate if non specified neither found
PATCH 1/1 xen/uart: set a default baudrate if non specified neither found
If the user has set baudrate as "auto" (use whatever was configured) but Xen cannot find any set baudrate use a default fallback baudrate of 115200.
Otherwise the console will very likely end up being non-functional, as further values are derived from the baudrate (like the transmit timeout), and using -1 will result in screwed parameters being derived from the baudrate.
Signed-off-by Roger Pau Monné <[email protected]>
--- xen/drivers/char/ns16550.c | 9 ++++++++- 1 file changed, 8 insertions(+), 1 deletion(-)
xen/drivers/char/ns16550.c +8 -1
@@ -346,9 +346,16 @@ static void ns16550_setup_preirq(struct ns16550 *uart)if ( divisor ) uart->baud = uart->clock_hz / (divisor <<4 );else + { + uart->baud =115200 ;printk (XENLOG_ERR "Automatic baud rate determination was requested," -" but a baud rate was not set up\n" ); +" but a baud rate was not set up\n" +"Setting baudrate to %u\n" , uart->baud); + divisor = uart->clock_hz / (uart->baud <<4 ); +ns_write_reg (uart,UART_DLL , (uint8_t )divisor); +ns_write_reg (uart,UART_DLM , (uint8_t )(divisor >>8 )); + } }ns_write_reg (uart,UART_LCR , lcr);
Signature · 1 line
2.51.0