libmultipath: Handle SCSI-2 style vpd page 0x83 descriptors
Benjamin Marzinski
maintainerPATCH v2 1/1 libmultipath: Handle SCSI-2 style vpd page 0x83 descriptors
Some older SCSI devices return a SCSI-2 style vpd page 0x83, instead of a SPC-2/3 format one. The SCSI-2 page 83 format returns an IEEE WWN in binary encoded hexi-decimal in the 16 bytes following the initial 4-byte page 83 reply header.
Check the 7th byte of the vpd page 83 buffer to determine whether this is a SCSI-2 or SPC-2/3 confomant one. Byte 7 is the 3rd byte of first Identification descriptor in a SPC-2/3 confromant vpd page 83. This is a reserved field, and is guaranteed to be 0. If it is not zero, then it is likely the 3rd byte of a SCSI-2 Identifier (The first 3 bytes of the ID are the Organizationally Unique Identifier). Both the sg_inq and scsi_id commands handle vpd page 83 this way. To make sure that the WWID which multipath reads directly from the device matches, it should handle this format as well.
---
Changes in v2 (suggested by Martin Wilck):
- check that the vpd page is large enough to be a valid SCSI-2 style one.
libmultipath/discovery.c | 13 +++++++++ tests/vpd.c | 58 ++++++++++++++++++++++++++++++++++++++++ 2 files changed, 71 insertions(+)
libmultipath/discovery.c +13 -0
@@ -1208,6 +1208,18 @@ parse_vpd_pg83(const unsigned char *in, size_t in_len,if (out_len <=1 )return 0 ; +/* +* Not a valid SPC-2/3 vpd page 83. Assume it's a SCSI-2 style +* descriptor. +*/ +if (in_len >=20 && in[6 ] !=0 ) { + len =0 ; + vpd_type =0x3 ; + vpd_len = in_len -4 ; + vpd = in +4 ; + goto decode; + } + d = in +4 ;while (d <= in + in_len -4 ) {bool invalid = false;
@@ -1323,6 +1335,7 @@ parse_vpd_pg83(const unsigned char *in, size_t in_len, vpd_type = vpd[1 ] &0xf ; vpd_len = vpd[3 ]; vpd +=4 ; +decode:/* untaint vpd_len for coverity */ if (vpd_len >WWID_SIZE ) { condlog(1, "%s: suspicious designator length %zu truncated to %u",
tests/vpd.c +58 -0
82 lines not on this page · raw message
Signature · 1 line
2.53.0
Quoted 24 lines · Benjamin Marzinski
Some older SCSI devices return a SCSI-2 style vpd page
0x83, instead of
a SPC-2/3 format one. The SCSI-2 page 83 format returns an IEEE WWN in
binary encoded hexi-decimal in the 16 bytes following the initial 4-byte page 83 reply header.Check the 7th byte of the vpd page 83 buffer to determine whether this
is a SCSI-2 or SPC-2/3 confomant one. Byte 7 is the 3rd byte of first Identification descriptor in a SPC-2/3 confromant vpd page 83. This is a
reserved field, and is guaranteed to be 0. If it is not zero, then it is
likely the 3rd byte of a SCSI-2 Identifier (The first 3 bytes of the ID
are the Organizationally Unique Identifier). Both thesg_inqandscsi_id
commands handle vpd page 83 this way. To make sure that the WWID which
multipath reads directly from the device matches, it should handle this
format as well.
Quoted 1 line
Signed-off-by Benjamin Marzinski <[email protected]>