iio: magnetometer: hid-sensor-magn-3d: prefer 'u32' type
Subsystems (3)
PATCH v3 1/1 iio: magnetometer: hid-sensor-magn-3d: prefer 'u32' type
Use 'u32' instead of bare 'unsigned' to resolve checkpatch.pl warnings and correct type use as defined in the struct hid_sensor_hub_callbacks.
No functional change.
Reviewed-by Andy Shevchenko <[email protected]>
Signed-off-by Joshua Crofts <[email protected]>
---
v2:
- changed 'unsigned int' to 'u32' per struct definition
v3:
- commit message edits
drivers/iio/magnetometer/hid-sensor-magn-3d.c | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-)
drivers/iio/magnetometer/hid-sensor-magn-3d.c +3 -3
@@ -280,7 +280,7 @@ static const struct iio_info magn_3d_info = {/* Callback handler to send event after all samples are received and captured */ static int magn_3d_proc_event (struct hid_sensor_hub_device *hsdev, -unsigned usage_id, +u32 usage_id,void *priv) {struct iio_dev *indio_dev =platform_get_drvdata (priv);
@@ -302,7 +302,7 @@ static int magn_3d_proc_event(struct hid_sensor_hub_device *hsdev,/* Capture samples in local storage */ static int magn_3d_capture_sample (struct hid_sensor_hub_device *hsdev, -unsigned usage_id, +u32 usage_id,size_t raw_len,char *raw_data,void *priv) {
@@ -350,7 +350,7 @@ static int magn_3d_parse_report(struct platform_device *pdev,struct hid_sensor_hub_device *hsdev, struct iio_chan_spec **channels, int *chan_count, - unsigned usage_id, + u32 usage_id, struct magn_3d_state *st) { int i;
Signature · 1 line
2.47.3
Quoted 8 lines · On Tue, 21 Apr 2026 06:58:37 +0000 Joshua Crofts <[email protected]>…
Use 'u32' instead of bare 'unsigned' to resolve checkpatch.pl warnings and correct type use as defined in the struct
hid_sensor_hub_callbacks.No functional change.
Reviewed-by Andy Shevchenko <[email protected]>Signed-off-by Joshua Crofts <[email protected]>
Applied.
Thanks,
J