watchdog: realtek-otto: various fixes
Subsystems (2)
Sander Vanheule
maintainercover watchdog: realtek-otto: various fixes
These patches fix some minor issues with the current code, as reported in [1]. The individual patches can be applied in any order.
Should I add a Reported-by for the Sashiko review, or how should this be handled?
[1] https://patch.msgid.link/[email protected]/
Sander Vanheule (2):
watchdog: realtek-otto: prevent PHASE2 underflows
watchdog: realtek-otto: enable clock before using I/O
drivers/watchdog/realtek_otto_wdt.c | 20 +++++++------------- 1 file changed, 7 insertions(+), 13 deletions(-)
Signature · 1 line
2.54.0
Sander Vanheule
maintainerPATCH 1/2 watchdog: realtek-otto: prevent PHASE2 underflows
For small pretimeout values, ((timeout - pretimeout) / tick) might be rounded up to the same value as (timeout / tick). As a result, the number of PHASE2 ticks may be zero, causing an underflow when subtracting 1 to configure the hardware. While this results in a longer-than-expected time to system reset, the duration of PHASE1 and minimum ping interval for the watchdog would still be correct.
As the watchdog core ensures pretimeout is strictly less than timeout, ceil(timeout / tick) is strictly greater than floor(pretimeout / tick) and the number of PHASE1 ticks cannot be 0. So instead of rounding up the number of PHASE1 ticks, we can round down the number of PHASE2 ticks, maintaining the current behavior while avoiding underflows.
The original helper function is now inlined, as it doesn't save any duplication anymore.
--- drivers/watchdog/realtek_otto_wdt.c | 12 +++--------- 1 file changed, 3 insertions(+), 9 deletions(-)
drivers/watchdog/realtek_otto_wdt.c +3 -9
@@ -114,12 +114,6 @@ static int otto_wdt_tick_ms(struct otto_wdt_ctrl *ctrl, int prescale)* the value stored in those fields. This means each phase will run for at least * one tick, so small values need to be clamped to correctly reflect the timeout. */ -static inline unsigned int div_round_ticks (unsigned int val,unsigned int tick_duration, -unsigned int min_ticks) -{ -return max (min_ticks,DIV_ROUND_UP (val, tick_duration)); -} -static int otto_wdt_determine_timeouts (struct watchdog_device *wdev,unsigned int timeout,unsigned int pretimeout) {
@@ -140,9 +134,9 @@ static int otto_wdt_determine_timeouts(struct watchdog_device *wdev, unsigned inreturn -EINVAL ; tick_ms =otto_wdt_tick_ms (ctrl, prescale); - total_ticks =div_round_ticks (timeout_ms, tick_ms,2 ); - phase1_ticks =div_round_ticks (timeout_ms - pretimeout_ms, tick_ms,1 ); - phase2_ticks = total_ticks - phase1_ticks; + total_ticks =max (2 ,DIV_ROUND_UP (timeout_ms, tick_ms)); + phase2_ticks =max (1 , pretimeout_ms / tick_ms); + phase1_ticks = total_ticks - phase2_ticks; prescale_next++; } while (phase1_ticks > OTTO_WDT_PHASE_TICKS_MAX
Signature · 1 line
2.54.0
Re: [PATCH 1/2] watchdog: realtek-otto: prevent PHASE2 underflows
Quoted 13 lines · Sander Vanheule
For small pretimeout values, ((timeout - pretimeout) / tick) might be rounded up to the same value as (timeout / tick). As a result, the number of PHASE2 ticks may be zero, causing an underflow when subtracting 1 to configure the hardware. While this results in a longer-than-expected time to system reset, the duration of PHASE1 and minimum ping interval for the watchdog would still be correct.
As the watchdog core ensures pretimeout is strictly less than timeout, ceil(timeout / tick) is strictly greater than floor(pretimeout / tick) and the number of PHASE1 ticks cannot be 0. So instead of rounding up the number of PHASE1 ticks, we can round down the number of PHASE2 ticks, maintaining the current behavior while avoiding underflows.
Quoted 4 lines
The original helper function is now inlined, as it doesn't save any duplication anymore.
Signed-off-by Sander Vanheule <[email protected]>
Applied.
Thanks,
Guenter
Quoted 34 lines
--- drivers/watchdog/realtek_otto_wdt.c | 12 +++--------- 1 file changed, 3 insertions(+), 9 deletions(-)drivers/watchdog/realtek_otto_wdt.c +3
-9@@ -114,12 +114,6 @@ static int otto_wdt_tick_ms(struct otto_wdt_ctrl *ctrl, int prescale)* the value stored in those fields. This means each phase will run for at least * one tick, so small values need to be clamped to correctly reflect the timeout. */ -static inline unsigned int div_round_ticks (unsigned int val,unsigned int tick_duration, -unsigned int min_ticks) -{ -return max (min_ticks,DIV_ROUND_UP (val, tick_duration)); -} -static int otto_wdt_determine_timeouts (struct watchdog_device *wdev,unsigned int timeout,unsigned int pretimeout) {@@ -140,9 +134,9 @@ static int otto_wdt_determine_timeouts(struct watchdog_device *wdev, unsigned inreturn -EINVAL ; tick_ms =otto_wdt_tick_ms (ctrl, prescale); - total_ticks =div_round_ticks (timeout_ms, tick_ms,2 ); - phase1_ticks =div_round_ticks (timeout_ms - pretimeout_ms, tick_ms,1 ); - phase2_ticks = total_ticks - phase1_ticks; + total_ticks =max (2 ,DIV_ROUND_UP (timeout_ms, tick_ms)); + phase2_ticks =max (1 , pretimeout_ms / tick_ms); + phase1_ticks = total_ticks - phase2_ticks; prescale_next++; } while (phase1_ticks > OTTO_WDT_PHASE_TICKS_MAX
Sander Vanheule
maintainerPATCH 2/2 watchdog: realtek-otto: enable clock before using I/O
In reply to Sander VanheuleAs the watchdog is normally on the same bus as the UART peripheral, the bootloader will have ensured the bus' clock is up and running before the watchdog driver is probed. Nevertheless, let's do things the right way and enable the watchdog's clock before performing I/O accesses.
--- drivers/watchdog/realtek_otto_wdt.c | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-)
drivers/watchdog/realtek_otto_wdt.c +4 -4
@@ -296,15 +296,15 @@ static int otto_wdt_probe(struct platform_device *pdev)if (IS_ERR (ctrl->base))return PTR_ERR (ctrl->base); + ret =otto_wdt_probe_clk (ctrl); +if (ret) +return ret; +/* Clear any old interrupts and reset initial state */ iowrite32 (OTTO_WDT_INTR_PHASE_1 |OTTO_WDT_INTR_PHASE_2 , ctrl->base +OTTO_WDT_REG_INTR );iowrite32 (OTTO_WDT_CTRL_DEFAULT , ctrl->base +OTTO_WDT_REG_CTRL ); - ret =otto_wdt_probe_clk (ctrl); -if (ret) -return ret; - ctrl->irq_phase1 =platform_get_irq_byname (pdev,"phase1" );if (ctrl->irq_phase1 <0 )return ctrl->irq_phase1;
Signature · 1 line
2.54.0
Re: [PATCH 2/2] watchdog: realtek-otto: enable clock before using I/O
Quoted 6 lines · Sander Vanheule
As the watchdog is normally on the same bus as the UART peripheral, the bootloader will have ensured the bus' clock is up and running before the watchdog driver is probed. Nevertheless, let's do things the right way and enable the watchdog's clock before performing I/O accesses.
Signed-off-by Sander Vanheule <[email protected]>
Applied.
Thanks,