net/ice: use configured outer TPID for VLAN filter in DVM
PATCH 1/1 net/ice: use configured outer TPID for VLAN filter in DVM
In Double VLAN Mode (DVM), the hardware switch recipe ICE_SW_LKUP_VLAN matches on both the VLAN ID and the TPID. Previously, ice_vlan_filter_set() always initialized the VLAN filter with the hardcoded RTE_ETHER_TYPE_VLAN (0x8100), regardless of the outer TPID configured by the user via vlan_tpid_set().
This caused a mismatch when a non-standard outer TPID such as 0x88a8 (IEEE 802.1ad) was configured: the hardware filter was programmed with TPID 0x8100 while incoming packets carried TPID 0x88a8, resulting in all such packets being dropped by the VLAN pruning logic.
Fix this by replacing the hardcoded RTE_ETHER_TYPE_VLAN with pf->outer_ethertype in the ICE_VLAN() macro call. This field is already updated by ice_vlan_tpid_set() when the user configures the outer TPID, and defaults to RTE_ETHER_TYPE_VLAN at initialization, so the change is safe for standard 802.1q traffic.
In SVM, the TPID is not part of the hardware lookup key, so this change has no functional impact in that mode.
--- drivers/net/intel/ice/ice_ethdev.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-)
drivers/net/intel/ice/ice_ethdev.c +2 -1
@@ -5038,7 +5038,8 @@ static int ice_vlan_filter_set(struct rte_eth_dev *dev, uint16_t vlan_id, int on) { struct ice_pf *pf = ICE_DEV_PRIVATE_TO_PF(dev->data->dev_private); -struct ice_vlan vlan =ICE_VLAN (RTE_ETHER_TYPE_VLAN , vlan_id); +/* Use the configured outer_ethertype instead of hardcoded 0x8100 */ +struct ice_vlan vlan =ICE_VLAN (pf->outer_ethertype, vlan_id);struct ice_vsi *vsi = pf->main_vsi;int ret;
Signature · 1 line
2.43.0
Quoted 18 lines · KAVYA AV
In Double VLAN Mode (DVM), the hardware switch recipe
ICE_SW_LKUP_VLANmatches on both the VLAN ID and the TPID. Previously,ice_vlan_filter_set()always initialized the VLAN filter with the hardcodedRTE_ETHER_TYPE_VLAN(0x8100), regardless of the outer TPID configured by the user viavlan_tpid_set().This caused a mismatch when a non-standard outer TPID such as
0x88a8(IEEE 802.1ad) was configured: the hardware filter was programmed with TPID0x8100while incoming packets carried TPID0x88a8, resulting in all such packets being dropped by the VLAN pruning logic.Fix this by replacing the hardcoded
RTE_ETHER_TYPE_VLANwithpf->outer_ethertypein theICE_VLAN()macro call. This field is already updated byice_vlan_tpid_set()when the user configures the outer TPID, and defaults toRTE_ETHER_TYPE_VLANat initialization, so the change is safe for standard 802.1q traffic.
Quoted 7 lines
In SVM, the TPID is not part of the hardware lookup key, so this change has no functional impact in that mode.
Fixes 295b34f55b00 ("net/ice: fix VLAN 0 adding based on VLAN mode")Signed-off-by KAVYA AV <[email protected]>
Applied to dpdk-next-net-intel.
Thanks,
/Bruce