iio: proximity: vl53l0x-i2c: claim direct mode for raw reads
Subsystems (2)
PATCH 1/1 iio: proximity: vl53l0x-i2c: claim direct mode for raw reads
vl53l0x_read_raw() starts a single-shot ranging measurement and reads back the result. Once the triggered buffer is enabled the sensor runs in continuous mode and its data-ready interrupt is routed to the trigger, so a concurrent in_distance_raw read disturbs the streaming setup and never gets its completion, returning -ETIMEDOUT.
The original submission claimed direct mode here, but it was dropped during review because the driver had no buffer support at the time [1]. Continuous (buffered) mode was later added without restoring the claim [2], reintroducing the conflict.
Reject direct reads while buffered capture is active by claiming direct mode around the measurement, as the vl53l1x sibling already does.
---
Only compile-tested; I don't have VL53L0X hardware to exercise the race yet. The change mirrors the existing vl53l1x sibling.
drivers/iio/proximity/vl53l0x-i2c.c | 3 +++ 1 file changed, 3 insertions(+)
drivers/iio/proximity/vl53l0x-i2c.c +3 -0
@@ -219,7 +219,10 @@ static int vl53l0x_read_raw(struct iio_dev *indio_dev,switch (mask) {case IIO_CHAN_INFO_RAW : +if (!iio_device_claim_direct (indio_dev)) +return -EBUSY ; ret =vl53l0x_read_proximity (data, chan, val); +iio_device_release_direct (indio_dev);if (ret <0 )return ret;
Signature · 1 line
2.53.0
Quoted 11 lines · On Wed, 2 Sep 2026 00:21:26 +0900 Donggeun Yoo <[email protected]>…
vl53l0x_read_raw()starts a single-shot ranging measurement and reads back the result. Once the triggered buffer is enabled the sensor runs in continuous mode and its data-ready interrupt is routed to the trigger, so a concurrentin_distance_rawread disturbs the streaming setup and never gets its completion, returning-ETIMEDOUT.The original submission claimed direct mode here, but it was dropped during review because the driver had no buffer support at the time [1]. Continuous (buffered) mode was later added without restoring the claim [2], reintroducing the conflict.
Quoted 7 lines
Reject direct reads while buffered capture is active by claiming direct mode around the measurement, as the vl53l1x sibling already does.
Fixes 762186c6e7b1 ("iio: proximity: vl53l0x-i2c: Added continuous mode support")Signed-off-by Donggeun Yoo <[email protected]>
Applied to the fixes-togreg branch of iio.git.
Thanks,
Jonathan
Quoted 22 lines
---
Only compile-tested; I don't have VL53L0X hardware to exercise the race yet. The change mirrors the existing vl53l1x sibling.drivers/iio/proximity/vl53l0x-i2c.c | 3 +++ 1 file changed, 3 insertions(+)drivers/iio/proximity/vl53l0x-i2c.c +3
-0@@ -219,7 +219,10 @@ static int vl53l0x_read_raw(struct iio_dev *indio_dev,switch (mask) {case IIO_CHAN_INFO_RAW : +if (!iio_device_claim_direct (indio_dev)) +return -EBUSY ; ret =vl53l0x_read_proximity (data, chan, val); +iio_device_release_direct (indio_dev);if (ret <0 )return ret;