net/mlx5: fix suffix groups without default FDB rule
PATCH 1/1 net/mlx5: fix suffix groups without default FDB rule
With fdb_def_rule_en=0, mlx5 SWS still decrements meter and sampler suffix groups, causing continuation rules to be installed in the wrong tables.
Decrement these groups only when the default FDB rule is active, keeping suffix placement consistent with group-to-table translation.
Fixes 1939eb6f660c ("net/mlx5: support flow port action with HWS")
Cc Dariusz Sosnowski <[email protected]>
Signed-off-by Rongwei Liu <[email protected]>
--- drivers/net/mlx5/mlx5_flow.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
drivers/net/mlx5/mlx5_flow.c +2 -2
@@ -7048,7 +7048,7 @@ flow_create_split_meter(struct rte_eth_dev *dev, goto exit; }/* Setting the sfx group atrr. */ - sfx_attr.group = sfx_attr.transfer ? + sfx_attr.group = (sfx_attr.transfer && priv->fdb_def_rule) ? (MLX5_FLOW_TABLE_LEVEL_METER -1 ) :MLX5_FLOW_TABLE_LEVEL_METER ; flow_split_info->prefix_layers =
@@ -7229,7 +7229,7 @@ flow_create_split_sample(struct rte_eth_dev *dev, sfx_tbl_data =container_of (sfx_tbl, struct mlx5_flow_tbl_data_entry, tbl); - sfx_attr.group = sfx_attr.transfer ? + sfx_attr.group = (sfx_attr.transfer && priv->fdb_def_rule) ? (sfx_tbl_data->level -1 ) : sfx_tbl_data->level; }else {MLX5_ASSERT (attr->transfer);
Signature · 1 line
2.53.0
Patch applied to next-net-mlx.