When PGLUE_B_REG_PF_BAR{0,1}_SIZE reads back as 0 on older management firmware with multi-hwfn devices, qed_hw_bar_size() logs that it assumes 256 KiB for GRC (BAR_ID_0) and 512 KiB for DB (BAR_ID_1), but evaluates:
return BAR_ID_0 ? 256 * 1024 : 512 * 1024;
Because BAR_ID_0 is enum constant 0, the ternary condition is always false and qed_hw_bar_size() unconditionally returns 512 KiB even for BAR_ID_0, doubling the computed GRC BAR offset for the second hardware function.
Compare bar_id == BAR_ID_0 as intended (matching the bar_reg selection at the top of qed_hw_bar_size()).
Found by enabling Clang's -Wunreachable-code on an x86_64 allyesconfig build, with AI coding assistant help to audit the warning and prepare the fix. Build-tested with Clang; not runtime-tested on QLogic hardware.
--- drivers/net/ethernet/qlogic/qed/qed_dev.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
drivers/net/ethernet/qlogic/qed/qed_dev.c +2 -2
@@ -1264,11 +1264,11 @@ static u32 qed_hw_bar_size(struct qed_hwfn *p_hwfn,if (p_hwfn->cdev->num_hwfns >1 ) {DP_INFO (p_hwfn,"BAR size not configured. Assuming BAR size of 256kB for GRC and 512kB for DB\n" ); -return BAR_ID_0 ?256 *1024 :512 *1024 ; +return bar_id ==BAR_ID_0 ?256 *1024 :512 *1024 ; }else {DP_INFO (p_hwfn,"BAR size not configured. Assuming BAR size of 512kB for GRC and 512kB for DB\n" ); -return 512 *1024 ; +return 512 *1024 ; } }
Signature · 1 line
2.56.1.708.g77570a6a1d-goog
Quoted 14 lines
When PGLUE_B_REG_PF_BAR{0,1}_SIZE reads back as 0 on older management firmware with multi-hwfn devices,
qed_hw_bar_size()logs that it assumes 256 KiB for GRC (BAR_ID_0) and 512 KiB for DB (BAR_ID_1), but evaluates:return
BAR_ID_0? 256 * 1024 : 512 * 1024;Because
BAR_ID_0is enum constant 0, the ternary condition is always false andqed_hw_bar_size()unconditionally returns 512 KiB even forBAR_ID_0, doubling the computed GRC BAR offset for the second hardware function.Compare
bar_id==BAR_ID_0as intended (matching thebar_regselection at the top ofqed_hw_bar_size()).
Quoted 6 lines
Found by enabling Clang's -Wunreachable-code on an
x86_64allyesconfig build, with AI coding assistant help to audit the warning and prepare the fix. Build-tested with Clang; not runtime-tested on QLogic hardware.Fixes c2035eea3e9e ("qed: Correct BAR sizes for older MFW")Signed-off-by Ian Rogers <[email protected]>