power: supply: s2mu005-battery: add S2MU106
Subsystems (2)
v2 cover power: supply: s2mu005-battery: add S2MU106
Add the Samsung S2MU106 fuel gauge (found on the Samsung Galaxy XCover5, Exynos850) to the s2mu005-battery driver. It has the same direct voltage, current and state-of-charge registers as the S2MU005 but no MONOUT averaging, so it gets its own compatible and match data. The XCover5 does not wire the gauge's alert line, hence patch 2.
This supersedes the standalone s2mu106-fuelgauge series [1], as asked by Kaustabh and Krzysztof.
[1] https://lore.kernel.org/all/[email protected]/
An AI coding assistant (Claude Code) helped compare the register maps and draft these patches. I reviewed and tested them on the device.
Changes in v2:
- binding: add the compatible to the enum, no s2mu005 fallback
- shorter commit messages
- Link to v1: https://lore.kernel.org/all/[email protected]/
---
Adil Hüsrev Tepe (3):
dt-bindings: power: supply: samsung,s2mu005-fuel-gauge: add S2MU106
power: supply: s2mu005-battery: make the alert interrupt optional
power: supply: s2mu005-battery: add S2MU106 support
.../power/supply/samsung,s2mu005-fuel-gauge.yaml | 1 + drivers/power/supply/s2mu005-battery.c | 71 ++++++++++++++++++---- 2 files changed, 59 insertions(+), 13 deletions(-)
---
base-commit: 6628e7d4c6b25c8d18f1345e3a20d21829aae7e4
change-id: 20261125-s2mu106-fg-5e2fc4490cbe
Best regards,
Signature · 1 line
Adil Hüsrev Tepe <[email protected]>
PATCH v2 1/3 dt-bindings: power: supply: samsung,s2mu005-fuel-gauge: add S2MU106
The fuel gauge in the Samsung S2MU106 PMIC has the same direct voltage, current and state-of-charge registers as the S2MU005 one, but lacks the MONOUT averaging registers, so it is not fully compatible. Add its own compatible.
--- .../devicetree/bindings/power/supply/samsung,s2mu005-fuel-gauge.yaml | 1 + 1 file changed, 1 insertion(+)
Documentation/devicetree/bindings/power/supply/samsung,s2mu005-fuel-gauge.yaml +1 -0
@@ -16,6 +16,7 @@ properties: compatible: enum: - samsung,s2mu005-fuel-gauge + - samsung,s2mu106-fuel-gauge reg: maxItems: 1
Signature · 1 line
2.53.0
PATCH v2 2/3 power: supply: s2mu005-battery: make the alert interrupt optional
In reply to Adil Hüsrev TepeThe driver unconditionally requests the fuel-gauge alert interrupt and fails to probe if the board does not wire it. Not all boards route the alert line (for example the Samsung Galaxy XCover5), so only request the interrupt when one is present; the gauge is otherwise polled on demand.
--- drivers/power/supply/s2mu005-battery.c | 12 +++++++----- 1 file changed, 7 insertions(+), 5 deletions(-)
drivers/power/supply/s2mu005-battery.c +7 -5
@@ -273,11 +273,13 @@ static int s2mu005_fg_i2c_probe(struct i2c_client *client)return dev_err_probe (dev,PTR_ERR (priv->psy),"failed to register power supply subsystem\n" ); - ret =devm_request_threaded_irq (priv->dev, client->irq,NULL , - s2mu005_handle_irq,IRQF_ONESHOT , - psy_desc->name, priv); -if (ret) -return dev_err_probe (dev, ret,"failed to request IRQ\n" ); +if (client->irq >0 ) { + ret =devm_request_threaded_irq (priv->dev, client->irq,NULL , + s2mu005_handle_irq,IRQF_ONESHOT , + psy_desc->name, priv); +if (ret) +return dev_err_probe (dev, ret,"failed to request IRQ\n" ); + }return 0 ; }
Signature · 1 line
2.53.0
PATCH v2 3/3 power: supply: s2mu005-battery: add S2MU106 support
In reply to Adil Hüsrev TepeThe S2MU106 fuel gauge uses the same STATUS/RVBAT/RCURCC/RSOC registers and scaling as the S2MU005, but has no MONOUT averaging path; reading the averaged voltage and current through it returns bogus values. Add a per-variant descriptor so the S2MU106 exposes only the instantaneous voltage, current, capacity and status, and derive the status from the instantaneous current when no average is available.
--- drivers/power/supply/s2mu005-battery.c | 61 +++++++++++++++++++++++++++++----- 1 file changed, 52 insertions(+), 9 deletions(-)
drivers/power/supply/s2mu005-battery.c +52 -9
@@ -38,6 +38,7 @@ struct s2mu005_fg {struct regmap *regmap;struct power_supply *psy;struct mutex monout_mutex; +bool has_monout; };static const struct regmap_config s2mu005_fg_regmap_config = {
@@ -168,16 +169,18 @@ static int s2mu005_fg_get_capacity(struct s2mu005_fg *priv, int *value)static int s2mu005_fg_get_status (struct s2mu005_fg *priv,int *value) { -int current_now, current_avg, capacity; +int current_now, current_avg =-1 , capacity;int ret; ret =s2mu005_fg_get_current_now (priv, ¤t_now);if (ret <0 )return ret; - ret =s2mu005_fg_get_current_avg (priv, ¤t_avg); -if (ret <0 ) -return ret; +if (priv->has_monout) { + ret =s2mu005_fg_get_current_avg (priv, ¤t_avg); +if (ret <0 ) +return ret; + }/* * Verify both current values reported to reduce inaccuracies due to
@@ -240,12 +243,47 @@ static const struct power_supply_desc s2mu005_fg_desc = { .get_property = s2mu005_fg_get_property, }; +/* +* The S2MU106 fuel gauge shares the direct STATUS/RVBAT/RCURCC/RSOC +* registers and their scaling, but not the MONOUT average-monitoring path, +* so the averaged voltage and current are not exposed on it. +*/ +static const enum power_supply_property s2mu106_fg_properties[] = { +POWER_SUPPLY_PROP_VOLTAGE_NOW , +POWER_SUPPLY_PROP_CURRENT_NOW , +POWER_SUPPLY_PROP_CAPACITY , +POWER_SUPPLY_PROP_STATUS , +}; + +static const struct power_supply_desc s2mu106_fg_desc = { + .name ="s2mu106-fuel-gauge" , + .type =POWER_SUPPLY_TYPE_BATTERY , + .properties = s2mu106_fg_properties, + .num_properties =ARRAY_SIZE (s2mu106_fg_properties), + .get_property = s2mu005_fg_get_property, +}; + +struct s2mu005_fg_variant { +const struct power_supply_desc *desc; +bool has_monout; +}; + +static const struct s2mu005_fg_variant s2mu005_fg_variant = { + .desc = &s2mu005_fg_desc, + .has_monout = true, +}; + +static const struct s2mu005_fg_variant s2mu106_fg_variant = { + .desc = &s2mu106_fg_desc, + .has_monout = false, +}; +static int s2mu005_fg_i2c_probe (struct i2c_client *client) {struct device *dev = &client->dev;struct s2mu005_fg *priv;struct power_supply_config psy_cfg = {}; -const struct power_supply_desc *psy_desc; +const struct s2mu005_fg_variant *variant;int ret; priv =devm_kzalloc (dev,sizeof (*priv),GFP_KERNEL );
@@ -264,11 +302,12 @@ static int s2mu005_fg_i2c_probe(struct i2c_client *client)if (ret)return dev_err_probe (dev, ret,"failed to initialize MONOUT mutex\n" ); - psy_desc =device_get_match_data (dev); + variant =device_get_match_data (dev); + priv->has_monout = variant->has_monout; psy_cfg.drv_data = priv; psy_cfg.fwnode =dev_fwnode (dev); - priv->psy =devm_power_supply_register (priv->dev, psy_desc, &psy_cfg); + priv->psy =devm_power_supply_register (priv->dev, variant->desc, &psy_cfg);if (IS_ERR (priv->psy))return dev_err_probe (dev,PTR_ERR (priv->psy),"failed to register power supply subsystem\n" );
@@ -276,7 +315,7 @@ static int s2mu005_fg_i2c_probe(struct i2c_client *client)if (client->irq >0 ) { ret =devm_request_threaded_irq (priv->dev, client->irq,NULL , s2mu005_handle_irq,IRQF_ONESHOT , - psy_desc->name, priv); + variant->desc->name, priv);if (ret)return dev_err_probe (dev, ret,"failed to request IRQ\n" ); }
@@ -287,7 +326,11 @@ static int s2mu005_fg_i2c_probe(struct i2c_client *client)static const struct of_device_id s2mu005_fg_of_match_table[] = { { .compatible ="samsung,s2mu005-fuel-gauge" , - .data = &s2mu005_fg_desc, + .data = &s2mu005_fg_variant, + }, + { + .compatible ="samsung,s2mu106-fuel-gauge" , + .data = &s2mu106_fg_variant, }, { } };
Signature · 1 line
2.53.0