Hi,

I would be explaining a rough idea of how we plan to go about, This is related to https://github.com/openbmc/openbmc/issues/2979

Please share your thoughts and feedback on this proposal.

=>we were planning to add the property in the chassis interface
which tells that since how many hours chassis was powered on.

=>This property gets updated by internal timer which wakes up after
an hour and updates this property if chassis is powered on.

1) Should we set the uptime to 0 if chassis state has been
transitioned from
PowerOn-->PowerOff

or

2) Don't update this property for the chassis power off duration and
update
this property when the chassis state changes to PowerOn.

What is community view on this?

Our opinion is that we should go with option 2 as other
implementation(AMI)
does the same.

=> In factory reset case this property will reset to 0.

=>If BMC has been rebooted due to any reason,This property will not
get updated for that duration and when BMC comes back,This timer kicks off and updates this property and it would be cumulative on what was the earlier value before BMC reboot.

=> Chassis object would be saved in nonvolatile storage to keep the last POH counter value.

=> Get functionality would be allowed,set would not be allowed from IPMI interface.

Regards
Ratan Gupta

#1 lore raw
Quoted 17 lines · Ratan Gupta

Hi,

I would be explaining a rough idea of how we plan to go about, This is related to https://github.com/openbmc/openbmc/issues/2979

Please share your thoughts and feedback on this proposal.

=>we were planning to add the property in the chassis interface
which tells that since how many hours chassis was powered on.

=>This property gets updated by internal timer which wakes up after
an hour and updates this property if chassis is powered on.

1) Should we set the uptime to 0 if chassis state has been
transitioned from
PowerOn-->PowerOff

Quoted 8 lines

or

2) Don't update this property for the chassis power off duration and
update
this property when the chassis state changes to PowerOn.

What is community view on this?

IMO, it depends on whether clients might be using this uptime to determine whether the host is on now; or maybe whether they might need to capture the latest uptime during some crash log that begins after the host goes down. My gut feeling is that it's correct to set it to zero when it powers off, and start incrementing it again starting when it powers on. But I also suppose it's not feasible to use uptime to determine current host state, if the value is stored in hours, since it would be almost one full hour before the value could report the host as "on"....

Is there a use case where someone might want to read the previous uptime, while the host is still down?

Quoted 7 lines

Our opinion is that we should go with option 2 as other
implementation(AMI)
does the same.

=> In factory reset case this property will reset to 0.

Quoted 8 lines

=>If BMC has been rebooted due to any reason,This property will not
get updated for that duration and when BMC comes back,This timer kicks off and updates this property and it would be cumulative on what was the earlier value before BMC reboot.

=> Chassis object would be saved in nonvolatile storage to keep the last POH counter value.

Would it make sense to store also the real time when it was last updated, so in case of BMC reboot like above, we could update the value to our best guess (assuming the host did not also restart while BMC was offline)?

Quoted 12 lines

=> Get functionality would be allowed,set would not be allowed from IPMI interface.

Regards
Ratan Gupta

#2 lore raw
Quoted 42 lines · Emily Shaffer

On Mon, Mar 26, 2018 at 5:00 AM Ratan Gupta <[email protected] <mailto:[email protected]>> wrote:

Hi,

I would be explaining a rough idea of how we plan to go about, This is related to https://github.com/openbmc/openbmc/issues/2979

Please share your thoughts and feedback on this proposal.

=>we were planning to add the property in the chassis interface which tells that since how many hours chassis was powered on.

=>This property gets updated by internal timer which wakes up after an hour and updates this property if chassis is powered on.

    1) Should we set the uptime to 0 if chassis state has been transitioned from
    PowerOn-->PowerOff

                              or

    2) Don't update this property for the chassis power off duration and
update
    this property when the chassis state changes to PowerOn.

    What is community view on this?

IMO, it depends on whether clients might be using this uptime to determine whether the host is on now; or maybe whether they might need to capture the latest uptime during some crash log that begins after the host goes down.  My gut feeling is that it's correct to set it to zero when it powers off, and start incrementing it again starting when it powers on.  But I also suppose it's not feasible to use uptime to determine current host state, if the value is stored in hours, since it would be almost one full hour before the value could report the host as "on"....

Quoted 2 lines

Is there a use case where someone might want to read the previous uptime, while the host is still down?

I believe, we must follow the IPMI specification, which clearly states in section 1.7.28 that the POH counter is:

"to return a counter value proportional to the system operating (S0) power-on hours"

It looks quite clear to me that this is similar to a car mileage meter. That is, a means to identify when it's time to do some servicing and/or track warranty.

The note in section 28.14 further backs my understanding and clarifies the matter:

======
Note that in a power-managed system, the definition of ‘powered up’ can be somewhat ambiguous. The definition
used here is that the power-on hours shall accumulate whenever the system is in the operational (S0) state. An
implementation may elect to increment power-on hours in the S1 and S2 states as well.

‘Clear’ or ‘Set’ commands are not specified for this counter. This is because the counter is most typically used for
warranty tracking or replacement purposes where changing or clearing the counter would defeat the purpose.
======

Hence, we need to elect whether or not we want to count S1 and S2 states (whatever they are called for POWER), but there shall be no doubt that the value is cumulative and must not be reset to zero.

P.S. I must say that I often see how the community is trying to reinvent IPMI without reading the specifications. I believe it is a very wrong approach, and I implore you all to first try to find the answer in the IPMI specification, and only when the answer can not be found, turn to other implementations like MegaRAC or anything.

Sincerely,
Alexander.

#3 lore raw
Quoted 12 lines · Alexander Amelkin
Quoted 5 lines · Ratan Gupta

2) Don't update this property for the chassis power off duration and
update
this property when the chassis state changes to PowerOn.

I believe, we must follow the IPMI specification, which clearly states in section 1.7.28 that the POH counter is:

"to return a counter value proportional to the system operating (S0) power-on hours"

It looks quite clear to me that this is similar to a car mileage meter. That is, a means to identify when it's time to do some servicing and/or track warranty.

Agreed. So option #2 then Alexander?

Quoted 2 lines

‘Clear’ or ‘Set’ commands are not specified for this counter. This is because the counter is most typically used for warranty tracking or replacement purposes where changing or clearing the counter would defeat the purpose.

So I take this as you don’t feel a factory reset should reset the counter, at least, certainly not by default. Agreed?

#4 lore raw
Quoted 6 lines · Brad Bishop
Quoted 6 lines · Alexander Amelkin
Quoted 5 lines · Ratan Gupta

2) Don't update this property for the chassis power off duration and
update
this property when the chassis state changes to PowerOn.

Quoted 6 lines
Quoted 5 lines

I believe, we must follow the IPMI specification, which clearly states in section 1.7.28 that the POH counter is:

"to return a counter value proportional to the system operating (S0) power-on hours"

It looks quite clear to me that this is similar to a car mileage meter. That is, a means to identify when it's time to do some servicing and/or track warranty.

Agreed. So option #2 then Alexander?

Yes.

Quoted 5 lines
Quoted 3 lines

‘Clear’ or ‘Set’ commands are not specified for this counter. This is because the counter is most typically used for warranty tracking or replacement purposes where changing or clearing the counter would defeat the purpose.

So I take this as you don’t feel a factory reset should reset the counter, at least, certainly not by default. Agreed?

Absolutely. We may want to have an OEM command to reset the POH counter, but I would prefer to only have a special tool available via shell under root account, and not let this counter be reset via IPMI or REST.