Question of pid-contorl on stepwise configuration
Quoted 75 lines
-----Original Message-----
From: James Feist <[email protected]>
Sent: Wednesday, September 4, 2019 8:43 AM
To: Derek Lin23 <[email protected]>; OpenBMC Maillist <[email protected]>
Subject: [External] Re: Question of pid-contorl on stepwise configurationQuoted 43 lines · On 8/21/2019 4:36 AM, Derek Lin23 wrote:
Hi team:
I have a question regarding stepwise configuration on
pid-control.I have mine setup like below.
{
"name": "
Ambient_Temp","type": "stepwise",
"setpoint": 0.0,
"inputs": ["
Ambient_Temp"],"pid": {
"samplePeriod": 1.0,
"positiveHysteresis": 0.0,
"negativeHysteresis": 0.0,
"isCeiling": false,
"reading": {
"0": 25,
"1": 30,
"2": 35
},
"output": {
"0": 15,
"1": 15,
Quoted 8 lines
"2": 15
}
}
}
I don't use the json configuration, so you'll have to do a bit of a comparison of apples and oranges, but here is an example of a stepwise configuration:
https://github.com/openbmc/entity-manager/blob/08a5b175eec81c53506709
fda8a7c168748cc22d/configurations/R1000%20Chassis.json#L577Reading is the reading of the sensor, and output is the setpoint given to the fan pid. Depending on how you configure your system this can either be a percent, or it can be a tach reading. When a sensor reaches a reading, the corresponding output is given to the fan controller as a setpoint. So it my example, when we reach a temp of 30 degrees, the setpoint of 60 is given to the fancontroller. This 60 is unitless and depends on how the fan controller configuration is implemented how it affects the fans.
Quoted 1 line
-James
Hi James:
I'll give it a try.
Thanks.
Quoted 41 lines
Quoted 41 lines
And, I would like to know the meaning of each field, as far
as I understand from phosphor-pid-control, "setpoint" seems not used if PID type is stepwise. Is that true? The "reading" field indicates the temperature reading from the sensor "Ambient". The "output" field should indicate the duty % corresponding to the fans, or should output be RPMs? That gives me when a reading of 25 degree(whatever the unit is), the output duty of fans should set to 15%, or set to corresponding RPMs.Do I understand the fields correctly?
Thank you,
------------------------------------------------------------------------
*Derek Lin*
Sr. BMC Engineer
8F,66, San Chong Rd., Nankang Software Park, Taipei. Lenovo TaiwanPhone+886281707411
[email protected] <mailto:[email protected]>Lenovo.com <http://www.lenovo.com/>
Twitter <http://twitter.com/lenovo> | Instagram
<https://instagram.com/lenovo> | Facebook
<http://www.facebook.com/lenovo> | Linkedin
<http://www.linkedin.com/company/lenovo> | YouTube
<http://www.youtube.com/lenovovision> | Privacy
<https://www.lenovo.com/gb/en/privacy-selector/>ImageLogo-DCG-Honeycomb