app/testpmd: dump TCI when asking for VLAN insertion
PATCH 1/1 app/testpmd: dump TCI when asking for VLAN insertion
I got some report for users that VLAN insertion was not working as the only thing they could see in verbose mode was a 0x0800 ethertype even though the RTE_MBUF_F_TX_VLAN flag was shown.
Dump the VLAN TCI from mbuf metadata when VLAN insertion is requested. This should enhance the situation.
Before:
src=76:4E:EA:3F:78:1D - dst=50:7C:6F:3C:10:5B - pool=mb_pool_1 -
type=0x0800 - length=64 - nb_segs=1 - sw ptype: L2_ETHER L3_IPV4 L4_UDP - l2_len=14 - l3_len=20 - l4_len=8 - Send queue=0x0
ol_flags: RTE_MBUF_F_TX_VLAN RTE_MBUF_F_TX_L4_NO_CKSUM
After:
src=76:4E:EA:3F:78:1D - dst=50:7C:6F:3C:10:5B - pool=mb_pool_1 -
type=0x0800 - length=64 - nb_segs=1 - VLAN tci=0x2a - sw ptype: L2_ETHER L3_IPV4 L4_UDP - l2_len=14 - l3_len=20 - l4_len=8 - Send queue=0x0
ol_flags: RTE_MBUF_F_TX_VLAN RTE_MBUF_F_TX_L4_NO_CKSUM
--- app/test-pmd/util.c | 6 ++++-- 1 file changed, 4 insertions(+), 2 deletions(-)
app/test-pmd/util.c +4 -2
@@ -180,11 +180,13 @@ dump_pkt_burst(uint16_t port_id, uint16_t queue, struct rte_mbuf *pkts[],if (is_timestamp_enabled (mb))MKDUMPSTR (print_buf, buf_size, cur_len," - timestamp %" PRIu64" " ,get_timestamp (mb)); -if (ol_flags &RTE_MBUF_F_RX_QINQ ) +if ((is_rx && (ol_flags &RTE_MBUF_F_RX_QINQ ) !=0 ) || + (!is_rx && (ol_flags &RTE_MBUF_F_TX_QINQ ) !=0 ))MKDUMPSTR (print_buf, buf_size, cur_len," - QinQ VLAN tci=0x%x, VLAN tci outer=0x%x" , mb->vlan_tci, mb->vlan_tci_outer); -else if (ol_flags &RTE_MBUF_F_RX_VLAN ) +else if ((is_rx && (ol_flags &RTE_MBUF_F_RX_VLAN ) !=0 ) || + (!is_rx && (ol_flags &RTE_MBUF_F_TX_VLAN ) !=0 ))MKDUMPSTR (print_buf, buf_size, cur_len," - VLAN tci=0x%x" , mb->vlan_tci);if (!is_rx && (ol_flags &RTE_MBUF_DYNFLAG_TX_METADATA ))
Signature · 1 line
2.44.0
Quoted 14 lines · David Marchand
I got some report for users that VLAN insertion was not working as the only thing they could see in verbose mode was a
0x0800ethertype even though theRTE_MBUF_F_TX_VLANflag was shown.Dump the VLAN TCI from mbuf metadata when VLAN insertion is requested. This should enhance the situation.
Before:
src=76:4E:EA:3F:78:1D - dst=50:7C:6F:3C:10:5B - pool=mb_pool_1 -type=0x0800 - length=64 - nb_segs=1 - sw ptype: L2_ETHER L3_IPV4 L4_UDP - l2_len=14 - l3_len=20 - l4_len=8 - Send queue=0x0
ol_flags:RTE_MBUF_F_TX_VLANRTE_MBUF_F_TX_L4_NO_CKSUM
Quoted 9 lines
After:
src=76:4E:EA:3F:78:1D - dst=50:7C:6F:3C:10:5B - pool=mb_pool_1 -type=0x0800 - length=64 - nb_segs=1 - VLAN tci=0x2a - sw ptype: L2_ETHER L3_IPV4 L4_UDP - l2_len=14 - l3_len=20 - l4_len=8 - Send queue=0x0
ol_flags:RTE_MBUF_F_TX_VLANRTE_MBUF_F_TX_L4_NO_CKSUMSigned-off-by David Marchand <[email protected]>
Applied to dpdk-next-net/main, thanks.