Skip to contentSkip to conversation

Improve EAS energy estimation and increase precision

PATCH Superseded Lukasz Luba 3 participants 7 messages Jul 20, 2021 – Aug 3, 2021

Subsystems (4)

v2 of 3 Superseded Latest is v3 →

lore
Share & tools
lore

Lukasz Luba

author maintainer
#0 lore raw

v2 cover Improve EAS energy estimation and increase precision

Hi all,

Here is a the v2 improving EAS estimation precision. The v1 and discussion can be found at:
https://lore.kernel.org/lkml/[email protected]/

changes:
v2:
- dropped first two patches
- implemented better resolution for 64-bit only machines according to Peter's comment and scale_load() example
- power value multiplied by 1000 not 10000
- added 'Fixes' tag, so it could be picked into stable trees easily
- extended patch descirpion with example corenr case scenario

Regards,
Lukasz

Lukasz Luba (1):
PM: EM: Increase energy calculation precision

 include/linux/energy_model.h | 16 ++++++++++++++++
 kernel/power/energy_model.c  |  3 ++-
 2 files changed, 18 insertions(+), 1 deletion(-)
Signature · 1 line
2.17.1
author maintainer
#1 lore raw

PATCH v2 1/1 PM: EM: Increase energy calculation precision

The Energy Model (EM) provides useful information about device power in each performance state to other subsystems like: Energy Aware Scheduler (EAS). The energy calculation in EAS does arithmetic operation based on the EM em_cpu_energy(). Current implementation of that function uses em_perf_state::cost as a pre-computed cost coefficient equal to:
cost = power * max_frequency / frequency.
The 'power' is expressed in milli-Watts (or in abstract scale).

There are corner cases when the EAS energy calculation for two Performance Domains (PDs) return the same value. The EAS compares these values to choose smaller one. It might happen that this values are equal due to rounding error. In such scenario, we need better resolution, e.g. 1000 times better. To provide this possibility increase the resolution in the em_perf_state::cost for 64-bit architectures. The costs for increasing resolution in 32-bit architectures are pretty high (64-bit division) and the returns do not justify the increased costs.

This patch allows to avoid the rounding to milli-Watt errors, which might occur in EAS energy estimation for each Performance Domains (PD). The rounding error is common for small tasks which have small utilization value.

There are two places in the code where it makes a difference:
1. In the find_energy_efficient_cpu() where we are searching for best_delta. We might suffer there when two PDs return the same result, like in the example below.

Scenario:
Low utilized system e.g. ~200 sum_util for PD0 and ~220 for PD1. There are quite a few small tasks ~10-15 util. These tasks would suffer for the rounding error. Such system utilization has been seen while playing some simple games. In such condition our partner reported 5..10mA less battery drain.

Some details:
We have two Perf Domains (PDs): PD0 (big) and PD1 (little) Let's compare w/o patch set ('old') and w/ patch set ('new') We are comparing energy w/ task and w/o task placed in the PDs

a) 'old' w/o patch set, PD0
task_util = 13
cost = 480
sum_util_w/o_task = 215
sum_util_w_task = 228
scale_cpu = 1024
energy_w/o_task = 480 * 215 / 1024 = 100.78 => 100 energy_w_task = 480 * 228 / 1024 = 106.87 => 106 energy_diff = 106 - 100 = 6
(this is equal to 'old' PD1's energy_diff in 'c)')

b) 'new' w/ patch set, PD0
task_util = 13
cost = 480 * 1000 = 480000
sum_util_w/o_task = 215
sum_util_w_task = 228
energy_w/o_task = 480000 * 215 / 1024 = 100781 energy_w_task = 480000 * 228 / 1024 = 106875 energy_diff = 106875 - 100781 = 6094
(this is not equal to 'new' PD1's energy_diff in 'd)')

c) 'old' w/o patch set, PD1
task_util = 13
cost = 160
sum_util_w/o_task = 283
sum_util_w_task = 293
scale_cpu = 355
energy_w/o_task = 160 * 283 / 355 = 127.55 => 127 energy_w_task = 160 * 296 / 355 = 133.41 => 133 energy_diff = 133 - 127 = 6
(this is equal to 'old' PD0's energy_diff in 'a)')

d) 'new' w/ patch set, PD1
task_util = 13
cost = 160 * 1000 = 160000
sum_util_w/o_task = 283
sum_util_w_task = 293
scale_cpu = 355
energy_w/o_task = 160000 * 283 / 355 = 127549
energy_w_task = 160000 * 296 / 355 = 133408
energy_diff = 133408 - 127549 = 5859
(this is not equal to 'new' PD0's energy_diff in 'b)')

2. Difference in the the last find_energy_efficient_cpu(): margin filter. With this patch the margin comparison also has better resolution, so it's possible to have better task placement thanks to that.

Fixes 27871f7a8a341ef ("PM: Introduce an Energy Model management framework")
---
 include/linux/energy_model.h | 16 ++++++++++++++++
 kernel/power/energy_model.c  |  3 ++-
 2 files changed, 18 insertions(+), 1 deletion(-)
include/linux/energy_model.h +16 -0
index 3f221dbf5f95..1834752c5617 100644
@@ -53,6 +53,22 @@ struct em_perf_domain {
 #ifdef CONFIG_ENERGY_MODEL
 #define EM_MAX_POWER 0xFFFF
 
+/*
+ * Increase resolution of energy estimation calculations for 64-bit
+ * architectures. The extra resolution improves decision made by EAS for the
+ * task placement when two Performance Domains might provide similar energy
+ * estimation values (w/o better resolution the values could be equal).
+ *
+ * We increase resolution only if we have enough bits to allow this increased
+ * resolution (i.e. 64-bit). The costs for increasing resolution when 32-bit
+ * are pretty high and the returns do not justify the increased costs.
+ */
+#ifdef CONFIG_64BIT
+#define em_scale_power(p) ((p) * 1000)
+#else
+#define em_scale_power(p) (p)
+#endif
+
 struct em_data_callback {
 	/**
 	 * active_power() - Provide power at the next performance state of
kernel/power/energy_model.c +2 -1
index 0f4530b3a8cd..bf312c04c514 100644
@@ -170,7 +170,8 @@ static int em_create_perf_table(struct device *dev, struct em_perf_domain *pd,
 	/* Compute the cost of each performance state. */
 	fmax = (u64) table[nr_states - 1].frequency;
 	for (i = 0; i < nr_states; i++) {
-		table[i].cost = div64_u64(fmax * table[i].power,
+		unsigned long power_res = em_scale_power(table[i].power);
+		table[i].cost = div64_u64(fmax * power_res,
 					  table[i].frequency);
 	}
 
Signature · 1 line
2.17.1
maintainer
#2 lore raw

Re: [PATCH v2 1/1] PM: EM: Increase energy calculation precision

Quoted 86 lines · Lukasz Luba

The Energy Model (EM) provides useful information about device power in each performance state to other subsystems like: Energy Aware Scheduler (EAS). The energy calculation in EAS does arithmetic operation based on the EM em_cpu_energy(). Current implementation of that function uses em_perf_state::cost as a pre-computed cost coefficient equal to:
cost = power * max_frequency / frequency.
The 'power' is expressed in milli-Watts (or in abstract scale).

There are corner cases when the EAS energy calculation for two Performance Domains (PDs) return the same value. The EAS compares these values to choose smaller one. It might happen that this values are equal due to rounding error. In such scenario, we need better resolution, e.g. 1000 times better. To provide this possibility increase the resolution in the em_perf_state::cost for 64-bit architectures. The costs for increasing resolution in 32-bit architectures are pretty high (64-bit division) and the returns do not justify the increased costs.

This patch allows to avoid the rounding to milli-Watt errors, which might occur in EAS energy estimation for each Performance Domains (PD). The rounding error is common for small tasks which have small utilization value.

There are two places in the code where it makes a difference:
1. In the find_energy_efficient_cpu() where we are searching for best_delta. We might suffer there when two PDs return the same result, like in the example below.

Scenario:
Low utilized system e.g. ~200 sum_util for PD0 and ~220 for PD1. There are quite a few small tasks ~10-15 util. These tasks would suffer for the rounding error. Such system utilization has been seen while playing some simple games. In such condition our partner reported 5..10mA less battery drain.

Some details:
We have two Perf Domains (PDs): PD0 (big) and PD1 (little) Let's compare w/o patch set ('old') and w/ patch set ('new') We are comparing energy w/ task and w/o task placed in the PDs

a) 'old' w/o patch set, PD0
task_util = 13
cost = 480
sum_util_w/o_task = 215
sum_util_w_task = 228
scale_cpu = 1024
energy_w/o_task = 480 * 215 / 1024 = 100.78 => 100 energy_w_task = 480 * 228 / 1024 = 106.87 => 106 energy_diff = 106 - 100 = 6
(this is equal to 'old' PD1's energy_diff in 'c)')

b) 'new' w/ patch set, PD0
task_util = 13
cost = 480 * 1000 = 480000
sum_util_w/o_task = 215
sum_util_w_task = 228
energy_w/o_task = 480000 * 215 / 1024 = 100781 energy_w_task = 480000 * 228 / 1024 = 106875 energy_diff = 106875 - 100781 = 6094
(this is not equal to 'new' PD1's energy_diff in 'd)')

c) 'old' w/o patch set, PD1
task_util = 13
cost = 160
sum_util_w/o_task = 283
sum_util_w_task = 293
scale_cpu = 355
energy_w/o_task = 160 * 283 / 355 = 127.55 => 127 energy_w_task = 160 * 296 / 355 = 133.41 => 133 energy_diff = 133 - 127 = 6
(this is equal to 'old' PD0's energy_diff in 'a)')

d) 'new' w/ patch set, PD1
task_util = 13
cost = 160 * 1000 = 160000
sum_util_w/o_task = 283
sum_util_w_task = 293
scale_cpu = 355
energy_w/o_task = 160000 * 283 / 355 = 127549
energy_w_task = 160000 * 296 / 355 = 133408
energy_diff = 133408 - 127549 = 5859
(this is not equal to 'new' PD0's energy_diff in 'b)')

2. Difference in the the last find_energy_efficient_cpu(): margin filter. With this patch the margin comparison also has better resolution, so it's possible to have better task placement thanks to that.

Quoted 8 lines
Fixes 27871f7a8a341ef ("PM: Introduce an Energy Model management framework")
---
 include/linux/energy_model.h | 16 ++++++++++++++++
 kernel/power/energy_model.c  |  3 ++-
 2 files changed, 18 insertions(+), 1 deletion(-)

<formletter>

This is not the correct way to submit patches for inclusion in the stable kernel tree. Please read:
https://www.kernel.org/doc/html/latest/process/stable-kernel-rules.html
for how to do this properly.

</formletter>

author maintainer
#3 lore raw

Re: [PATCH v2 1/1] PM: EM: Increase energy calculation precision

Hi Greg,

Quoted 1 line · Greg KH

On Tue, Jul 20, 2021 at 10:41:53AM +0100, Lukasz Luba wrote:

[snip]

Quoted 10 lines
Quoted 9 lines
Fixes 27871f7a8a341ef ("PM: Introduce an Energy Model management framework")
---
  include/linux/energy_model.h | 16 ++++++++++++++++
  kernel/power/energy_model.c  |  3 ++-
  2 files changed, 18 insertions(+), 1 deletion(-)
Quoted 9 lines

<formletter>

This is not the correct way to submit patches for inclusion in the stable kernel tree. Please read:
https://www.kernel.org/doc/html/latest/process/stable-kernel-rules.html
for how to do this properly.

</formletter>

I shouldn't have sent to CC -stable for now.
I will create and send a dedicated patch for stable with proper commit ID after it's merged (like I did last time). We are heading to stable 5.4+ (so the Android could get it).

Regards,
Lukasz

author maintainer
#4 lore raw

Re: [PATCH v2 1/1] PM: EM: Increase energy calculation precision

In reply to Lukasz Luba

Hi Peter, Vincent,

Gentle ping.

Quoted 127 lines · Lukasz Luba

The Energy Model (EM) provides useful information about device power in each performance state to other subsystems like: Energy Aware Scheduler (EAS). The energy calculation in EAS does arithmetic operation based on the EM em_cpu_energy(). Current implementation of that function uses em_perf_state::cost as a pre-computed cost coefficient equal to:
cost = power * max_frequency / frequency.
The 'power' is expressed in milli-Watts (or in abstract scale).

There are corner cases when the EAS energy calculation for two Performance Domains (PDs) return the same value. The EAS compares these values to choose smaller one. It might happen that this values are equal due to rounding error. In such scenario, we need better resolution, e.g. 1000 times better. To provide this possibility increase the resolution in the em_perf_state::cost for 64-bit architectures. The costs for increasing resolution in 32-bit architectures are pretty high (64-bit division) and the returns do not justify the increased costs.

This patch allows to avoid the rounding to milli-Watt errors, which might occur in EAS energy estimation for each Performance Domains (PD). The rounding error is common for small tasks which have small utilization value.

There are two places in the code where it makes a difference:
1. In the find_energy_efficient_cpu() where we are searching for best_delta. We might suffer there when two PDs return the same result, like in the example below.

Scenario:
Low utilized system e.g. ~200 sum_util for PD0 and ~220 for PD1. There are quite a few small tasks ~10-15 util. These tasks would suffer for the rounding error. Such system utilization has been seen while playing some simple games. In such condition our partner reported 5..10mA less battery drain.

Some details:
We have two Perf Domains (PDs): PD0 (big) and PD1 (little) Let's compare w/o patch set ('old') and w/ patch set ('new') We are comparing energy w/ task and w/o task placed in the PDs

a) 'old' w/o patch set, PD0
task_util = 13
cost = 480
sum_util_w/o_task = 215
sum_util_w_task = 228
scale_cpu = 1024
energy_w/o_task = 480 * 215 / 1024 = 100.78 => 100 energy_w_task = 480 * 228 / 1024 = 106.87 => 106 energy_diff = 106 - 100 = 6
(this is equal to 'old' PD1's energy_diff in 'c)')

b) 'new' w/ patch set, PD0
task_util = 13
cost = 480 * 1000 = 480000
sum_util_w/o_task = 215
sum_util_w_task = 228
energy_w/o_task = 480000 * 215 / 1024 = 100781 energy_w_task = 480000 * 228 / 1024 = 106875 energy_diff = 106875 - 100781 = 6094
(this is not equal to 'new' PD1's energy_diff in 'd)')

c) 'old' w/o patch set, PD1
task_util = 13
cost = 160
sum_util_w/o_task = 283
sum_util_w_task = 293
scale_cpu = 355
energy_w/o_task = 160 * 283 / 355 = 127.55 => 127 energy_w_task = 160 * 296 / 355 = 133.41 => 133 energy_diff = 133 - 127 = 6
(this is equal to 'old' PD0's energy_diff in 'a)')

d) 'new' w/ patch set, PD1
task_util = 13
cost = 160 * 1000 = 160000
sum_util_w/o_task = 283
sum_util_w_task = 293
scale_cpu = 355
energy_w/o_task = 160000 * 283 / 355 = 127549
energy_w_task = 160000 * 296 / 355 = 133408
energy_diff = 133408 - 127549 = 5859
(this is not equal to 'new' PD0's energy_diff in 'b)')

2. Difference in the the last find_energy_efficient_cpu(): margin filter. With this patch the margin comparison also has better resolution, so it's possible to have better task placement thanks to that.

Fixes 27871f7a8a341ef ("PM: Introduce an Energy Model management framework")
---
  include/linux/energy_model.h | 16 ++++++++++++++++
  kernel/power/energy_model.c  |  3 ++-
  2 files changed, 18 insertions(+), 1 deletion(-)
include/linux/energy_model.h +16 -0
index 3f221dbf5f95..1834752c5617 100644
@@ -53,6 +53,22 @@ struct em_perf_domain {
  #ifdef CONFIG_ENERGY_MODEL
  #define EM_MAX_POWER 0xFFFF
 
+/*
+ * Increase resolution of energy estimation calculations for 64-bit
+ * architectures. The extra resolution improves decision made by EAS for the
+ * task placement when two Performance Domains might provide similar energy
+ * estimation values (w/o better resolution the values could be equal).
+ *
+ * We increase resolution only if we have enough bits to allow this increased
+ * resolution (i.e. 64-bit). The costs for increasing resolution when 32-bit
+ * are pretty high and the returns do not justify the increased costs.
+ */
+#ifdef CONFIG_64BIT
+#define em_scale_power(p) ((p) * 1000)
+#else
+#define em_scale_power(p) (p)
+#endif
+
  struct em_data_callback {
  	/**
  	 * active_power() - Provide power at the next performance state of
kernel/power/energy_model.c +0 -0
index 0f4530b3a8cd..bf312c04c514 100644

kernel/power/energy_model.c static int em_create_perf_table(struct device *dev, struct em_perf_domain *pd, · line 177

Quoted 9 lines
kernel/power/energy_model.c +2 -1
@@ -170,7 +170,8 @@ static int em_create_perf_table(struct device *dev, struct em_perf_domain *pd,
  	/* Compute the cost of each performance state. */
  	fmax = (u64) table[nr_states - 1].frequency;
  	for (i = 0; i < nr_states; i++) {
-		table[i].cost = div64_u64(fmax * table[i].power,
+		unsigned long power_res = em_scale_power(table[i].power);
+		table[i].cost = div64_u64(fmax * power_res,
  					  table[i].frequency);
  	}
 

Do you have any comments to this patch?
It's EM-only change now, no other files touched.
If it's OK, I will ask Rafael to take it.

Regards,
Lukasz

Reviewed-by
#5 lore raw

Re: [PATCH v2 1/1] PM: EM: Increase energy calculation precision

Quoted 6 lines · Lukasz Luba

Hi Peter, Vincent,

Gentle ping.

On 7/20/21 10:41 AM, Lukasz Luba wrote:

[...]

Quoted 9 lines
Quoted 9 lines

There are corner cases when the EAS energy calculation for two Performance
Domains (PDs) return the same value. The EAS compares these values to choose smaller one. It might happen that this values are equal due to rounding error. In such scenario, we need better resolution, e.g. 1000 times better. To provide this possibility increase the resolution in the em_perf_state::cost for 64-bit architectures. The costs for increasing resolution in 32-bit architectures are pretty high (64-bit division) and the returns do not justify the increased costs.

s/The costs ... increased costs./The cost of increasing resolution on 32-bit is pretty high (64-bit division) and is not justified since there are no new 32bit big.LITTLE EAS systems expected which would benefit from this higher resolution./ ?

Quoted 2 lines
Quoted 2 lines

This patch allows to avoid the rounding to milli-Watt errors, which might occur in EAS energy estimation for each Performance Domains (PD). The

s/Performance Domains (PD)/PD.

[...]

Quoted 6 lines
Quoted 6 lines

Scenario:
Low utilized system e.g. ~200 sum_util for PD0 and ~220 for PD1. There are quite a few small tasks ~10-15 util. These tasks would suffer for the rounding error. Such system utilization has been seen while playing some simple games. In such condition our partner reported 5..10mA less battery drain.

Hard to digest: Maybe s/Such system ... battery drain./These utilization values are typical when running games on Android. One of our partners has reported 5..10mA less battery drain when running with increased resolution./ ?

Quoted 3 lines
Quoted 3 lines

Some details:
We have two Perf Domains (PDs): PD0 (big) and PD1 (little)

s/Perf Domains (PDs)/PDs

[...]

Quoted 1 line
Quoted 1 line

2. Difference in the the last find_energy_efficient_cpu(): margin filter.

s/in the the last find_energy_efficient_cpu(): margin filter/in the 6% energy margin filter at the end of find_energy_efficient_cpu()/ ?

Quoted 48 lines
Quoted 48 lines

With this patch the margin comparison also has better resolution, so it's possible to have better task placement thanks to that.

Fixes 27871f7a8a341ef ("PM: Introduce an Energy Model management

framework")

---
  include/linux/energy_model.h | 16 ++++++++++++++++ kernel/power/energy_model.c  |  3 ++-

  2 files changed, 18 insertions(+), 1 deletion(-)
include/linux/energy_model.h +0 -0
index 3f221dbf5f95..1834752c5617 100644
@@ -53,6 +53,22 @@ struct em_perf_domain {
   #ifdef CONFIG_ENERGY_MODEL
   #define EM_MAX_POWER 0xFFFF

  +/*
+ * Increase resolution of energy estimation calculations for 64-bit
+ * architectures. The extra resolution improves decision made by EAS for the
+ * task placement when two Performance Domains might provide similar energy
+ * estimation values (w/o better resolution the values could be equal).
+ *
+ * We increase resolution only if we have enough bits to allow this increased
+ * resolution (i.e. 64-bit). The costs for increasing resolution when 32-bit
+ * are pretty high and the returns do not justify the increased costs.
+ */

include/linux/energy_model.h +6 -0
+#ifdef CONFIG_64BIT
+#define em_scale_power(p) ((p) * 1000)
+#else
+#define em_scale_power(p) (p)
+#endif
+

  struct em_data_callback {
      /**
       * active_power() - Provide power at the next performance state of

kernel/power/energy_model.c +0 -0
index 0f4530b3a8cd..bf312c04c514 100644
@@ -170,7 +170,8 @@ static int em_create_perf_table(struct device
 *dev, struct em_perf_domain *pd,
Quoted 8 lines

kernel/power/energy_model.c static int em_create_perf_table(struct device *dev, struct em_perf_domain *pd, · line 176

Quoted 8 lines
kernel/power/energy_model.c +2 -1
       /* Compute the cost of each performance state. */
       fmax = (u64) table[nr_states - 1].frequency;
       for (i = 0; i < nr_states; i++) {
-        table[i].cost = div64_u64(fmax * table[i].power,
+        unsigned long power_res = em_scale_power(table[i].power);
+        table[i].cost = div64_u64(fmax * power_res,
                         table[i].frequency);
       }

Otherwise, LGTM.

This is now an EM only patch (Task scheduler (i.e. CFS/EAS) is only effected via compute_energy() -> em_cpu_energy().

author maintainer
#6 lore raw

Re: [PATCH v2 1/1] PM: EM: Increase energy calculation precision

Quoted 20 lines · Dietmar Eggemann
Quoted 6 lines · Lukasz Luba

Hi Peter, Vincent,

Gentle ping.

On 7/20/21 10:41 AM, Lukasz Luba wrote:

[...]

Quoted 9 lines
Quoted 9 lines

There are corner cases when the EAS energy calculation for two Performance
Domains (PDs) return the same value. The EAS compares these values to choose smaller one. It might happen that this values are equal due to rounding error. In such scenario, we need better resolution, e.g. 1000 times better. To provide this possibility increase the resolution in the em_perf_state::cost for 64-bit architectures. The costs for increasing resolution in 32-bit architectures are pretty high (64-bit division) and the returns do not justify the increased costs.

Quoted 4 lines

s/The costs ... increased costs./The cost of increasing resolution on 32-bit is pretty high (64-bit division) and is not justified since there are no new 32bit big.LITTLE EAS systems expected which would benefit from this higher resolution./ ?

Sounds better indeed.

Quoted 5 lines
Quoted 3 lines
Quoted 3 lines

This patch allows to avoid the rounding to milli-Watt errors, which might occur in EAS energy estimation for each Performance Domains (PD). The

s/Performance Domains (PD)/PD.

OK

Quoted 10 lines

[...]

Quoted 6 lines
Quoted 6 lines

Scenario:
Low utilized system e.g. ~200 sum_util for PD0 and ~220 for PD1. There are quite a few small tasks ~10-15 util. These tasks would suffer for the rounding error. Such system utilization has been seen while playing some simple games. In such condition our partner reported 5..10mA less battery drain.

Quoted 4 lines

Hard to digest: Maybe s/Such system ... battery drain./These utilization values are typical when running games on Android. One of our partners has reported 5..10mA less battery drain when running with increased resolution./ ?

Sounds good.

Quoted 6 lines
Quoted 4 lines
Quoted 4 lines

Some details:
We have two Perf Domains (PDs): PD0 (big) and PD1 (little)

s/Perf Domains (PDs)/PDs

OK

Quoted 7 lines

[...]

Quoted 1 line
Quoted 1 line

2. Difference in the the last find_energy_efficient_cpu(): margin filter.

s/in the the last find_energy_efficient_cpu(): margin filter/in the 6% energy margin filter at the end of find_energy_efficient_cpu()/ ?

OK

[snip]

Quoted 4 lines

Otherwise, LGTM.

Thank you Dietmar for the review. I'm going to send the v3.

Quoted 4 lines

This is now an EM only patch (Task scheduler (i.e. CFS/EAS) is only effected via compute_energy() -> em_cpu_energy().

True it's EM only now, so I will ask Rafael to pick it.