Skip to contentSkip to conversation

arm64: dts: mediatek: mt8186: fix clock names for power domains

PATCH Applied Eugen Hristev 4 participants 5 messages Oct 5, 2023 – Nov 29, 2023

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 arm64: dts: mediatek: mt8186: fix clock names for power domains

Clocks for each power domain are split into big categories: pd clocks and subsys clocks.
According to the binding, all clocks which have a dash '-' in their name are treated as subsys clocks, and must be placed at the end of the list. The other clocks which are pd clocks must come first.
Fixed the naming and the placing of all clocks in the power domains. For the avoidance of doubt, prefixed all subsys clocks with the 'subsys' prefix. The binding does not enforce strict clock names, the driver uses them in bulk, only making a difference for pd clocks vs subsys clocks.

The above problem appears to be trivial, however, it leads to incorrect power up and power down sequence of the power domains, because some clocks will be mistakenly taken for subsys clocks and viceversa. One consequence is the fact that if the DIS power domain goes power down and power back up during the boot process, when it comes back up, there are still transactions left on the bus which makes the display inoperable.

Some of the clocks for the DIS power domain were wrongly using '_' instead of '-', which again made these clocks being treated as pd clocks instead of subsys clocks.

Fixes d9e43c1e7a38 ("arm64: dts: mt8186: Add power domains controller")
---
 arch/arm64/boot/dts/mediatek/mt8186.dtsi | 42 +++++++++++++++---------
 1 file changed, 27 insertions(+), 15 deletions(-)
arch/arm64/boot/dts/mediatek/mt8186.dtsi +27 -15
index af6f6687de35..7121d4312bee 100644
@@ -924,7 +924,8 @@ power-domain@MT8186_POWER_DOMAIN_CSIRX_TOP {
 					reg = <MT8186_POWER_DOMAIN_CSIRX_TOP>;
 					clocks = <&topckgen CLK_TOP_SENINF>,
 						 <&topckgen CLK_TOP_SENINF1>;
-					clock-names = "csirx_top0", "csirx_top1";
+					clock-names = "subsys-csirx-top0",
+						      "subsys-csirx-top1";
 					#power-domain-cells = <0>;
 				};
 
@@ -942,7 +943,8 @@ power-domain@MT8186_POWER_DOMAIN_ADSP_AO {
 					reg = <MT8186_POWER_DOMAIN_ADSP_AO>;
 					clocks = <&topckgen CLK_TOP_AUDIODSP>,
 						 <&topckgen CLK_TOP_ADSP_BUS>;
-					clock-names = "audioadsp", "adsp_bus";
+					clock-names = "audioadsp",
+						      "subsys-adsp-bus";
 					#address-cells = <1>;
 					#size-cells = <0>;
 					#power-domain-cells = <1>;
@@ -975,8 +977,11 @@ power-domain@MT8186_POWER_DOMAIN_DIS {
 						 <&mmsys CLK_MM_SMI_COMMON>,
 						 <&mmsys CLK_MM_SMI_GALS>,
 						 <&mmsys CLK_MM_SMI_IOMMU>;
-					clock-names = "disp", "mdp", "smi_infra", "smi_common",
-						     "smi_gals", "smi_iommu";
+					clock-names = "disp", "mdp",
+						      "subsys-smi-infra",
+						      "subsys-smi-common",
+						      "subsys-smi-gals",
+						      "subsys-smi-iommu";
 					mediatek,infracfg = <&infracfg_ao>;
 					#address-cells = <1>;
 					#size-cells = <0>;
@@ -993,15 +998,17 @@ power-domain@MT8186_POWER_DOMAIN_VDEC {
 
 					power-domain@MT8186_POWER_DOMAIN_CAM {
 						reg = <MT8186_POWER_DOMAIN_CAM>;
-						clocks = <&topckgen CLK_TOP_CAM>,
-							 <&topckgen CLK_TOP_SENINF>,
+						clocks = <&topckgen CLK_TOP_SENINF>,
 							 <&topckgen CLK_TOP_SENINF1>,
 							 <&topckgen CLK_TOP_SENINF2>,
 							 <&topckgen CLK_TOP_SENINF3>,
+							 <&camsys CLK_CAM2MM_GALS>,
 							 <&topckgen CLK_TOP_CAMTM>,
-							 <&camsys CLK_CAM2MM_GALS>;
-						clock-names = "cam-top", "cam0", "cam1", "cam2",
-							     "cam3", "cam-tm", "gals";
+							 <&topckgen CLK_TOP_CAM>;
+						clock-names = "cam0", "cam1", "cam2",
+							      "cam3", "gals",
+							      "subsys-cam-tm",
+							      "subsys-cam-top";
 						mediatek,infracfg = <&infracfg_ao>;
 						#address-cells = <1>;
 						#size-cells = <0>;
@@ -1020,9 +1027,9 @@ power-domain@MT8186_POWER_DOMAIN_CAM_RAWA {
 
 					power-domain@MT8186_POWER_DOMAIN_IMG {
 						reg = <MT8186_POWER_DOMAIN_IMG>;
-						clocks = <&topckgen CLK_TOP_IMG1>,
-							 <&imgsys1 CLK_IMG1_GALS_IMG1>;
-						clock-names = "img-top", "gals";
+						clocks = <&imgsys1 CLK_IMG1_GALS_IMG1>,
+							 <&topckgen CLK_TOP_IMG1>;
+						clock-names = "gals", "subsys-img-top";
 						mediatek,infracfg = <&infracfg_ao>;
 						#address-cells = <1>;
 						#size-cells = <0>;
@@ -1041,8 +1048,11 @@ power-domain@MT8186_POWER_DOMAIN_IPE {
 							 <&ipesys CLK_IPE_LARB20>,
 							 <&ipesys CLK_IPE_SMI_SUBCOM>,
 							 <&ipesys CLK_IPE_GALS_IPE>;
-						clock-names = "ipe-top", "ipe-larb0", "ipe-larb1",
-							      "ipe-smi", "ipe-gals";
+						clock-names = "subsys-ipe-top",
+							      "subsys-ipe-larb0",
+							      "subsys-ipe-larb1",
+							      "subsys-ipe-smi",
+							      "subsys-ipe-gals";
 						mediatek,infracfg = <&infracfg_ao>;
 						#power-domain-cells = <0>;
 					};
@@ -1061,7 +1071,9 @@ power-domain@MT8186_POWER_DOMAIN_WPE {
 						clocks = <&topckgen CLK_TOP_WPE>,
 							 <&wpesys CLK_WPE_SMI_LARB8_CK_EN>,
 							 <&wpesys CLK_WPE_SMI_LARB8_PCLK_EN>;
-						clock-names = "wpe0", "larb-ck", "larb-pclk";
+						clock-names = "wpe0",
+							      "subsys-larb-ck",
+							      "subsys-larb-pclk";
 						mediatek,infracfg = <&infracfg_ao>;
 						#power-domain-cells = <0>;
 					};
Signature · 1 line
2.34.1
Tested-by on v1 1/1
#1 lore raw
Quoted 18 lines · Eugen Hristev

Clocks for each power domain are split into big categories: pd clocks and subsys clocks.
According to the binding, all clocks which have a dash '-' in their name are treated as subsys clocks, and must be placed at the end of the list. The other clocks which are pd clocks must come first.
Fixed the naming and the placing of all clocks in the power domains. For the avoidance of doubt, prefixed all subsys clocks with the 'subsys' prefix. The binding does not enforce strict clock names, the driver uses them in bulk, only making a difference for pd clocks vs subsys clocks.

The above problem appears to be trivial, however, it leads to incorrect power up and power down sequence of the power domains, because some clocks will be mistakenly taken for subsys clocks and viceversa. One consequence is the fact that if the DIS power domain goes power down and power back up during the boot process, when it comes back up, there are still transactions left on the bus which makes the display inoperable.

Quoted 6 lines

Some of the clocks for the DIS power domain were wrongly using '_' instead of '-', which again made these clocks being treated as pd clocks instead of subsys clocks.

Fixes d9e43c1e7a38 ("arm64: dts: mt8186: Add power domains controller")

This brings the display back to life on my MT8186 device. :D Thank you for tracking down the issue!

Quoted 107 lines
---
 arch/arm64/boot/dts/mediatek/mt8186.dtsi | 42 +++++++++++++++---------
 1 file changed, 27 insertions(+), 15 deletions(-)
arch/arm64/boot/dts/mediatek/mt8186.dtsi +27 -16
index af6f6687de35..7121d4312bee 100644
@@ -924,7 +924,8 @@ power-domain@MT8186_POWER_DOMAIN_CSIRX_TOP {
                                        reg = <MT8186_POWER_DOMAIN_CSIRX_TOP>;
                                        clocks = <&topckgen CLK_TOP_SENINF>,
                                                 <&topckgen CLK_TOP_SENINF1>;
-                                       clock-names = "csirx_top0", "csirx_top1";
+                                       clock-names = "subsys-csirx-top0",
+                                                     "subsys-csirx-top1";
                                        #power-domain-cells = <0>;
                                };
 
@@ -942,7 +943,8 @@ power-domain@MT8186_POWER_DOMAIN_ADSP_AO {
                                        reg = <MT8186_POWER_DOMAIN_ADSP_AO>;
                                        clocks = <&topckgen CLK_TOP_AUDIODSP>,
                                                 <&topckgen CLK_TOP_ADSP_BUS>;
-                                       clock-names = "audioadsp", "adsp_bus";
+                                       clock-names = "audioadsp",
+                                                     "subsys-adsp-bus";
                                        #address-cells = <1>;
                                        #size-cells = <0>;
                                        #power-domain-cells = <1>;
@@ -975,8 +977,11 @@ power-domain@MT8186_POWER_DOMAIN_DIS {
                                                 <&mmsys CLK_MM_SMI_COMMON>,
                                                 <&mmsys CLK_MM_SMI_GALS>,
                                                 <&mmsys CLK_MM_SMI_IOMMU>;
-                                       clock-names = "disp", "mdp", "smi_infra", "smi_common",
-                                                    "smi_gals", "smi_iommu";
+                                       clock-names = "disp", "mdp",
+                                                     "subsys-smi-infra",
+                                                     "subsys-smi-common",
+                                                     "subsys-smi-gals",
+                                                     "subsys-smi-iommu";
                                        mediatek,infracfg = <&infracfg_ao>;
                                        #address-cells = <1>;
                                        #size-cells = <0>;
@@ -993,15 +998,17 @@ power-domain@MT8186_POWER_DOMAIN_VDEC {
 
                                        power-domain@MT8186_POWER_DOMAIN_CAM {
                                                reg = <MT8186_POWER_DOMAIN_CAM>;
-                                               clocks = <&topckgen CLK_TOP_CAM>,
-                                                        <&topckgen CLK_TOP_SENINF>,
+                                               clocks = <&topckgen CLK_TOP_SENINF>,
                                                         <&topckgen CLK_TOP_SENINF1>,
                                                         <&topckgen CLK_TOP_SENINF2>,
                                                         <&topckgen CLK_TOP_SENINF3>,
+                                                        <&camsys CLK_CAM2MM_GALS>,
                                                         <&topckgen CLK_TOP_CAMTM>,
-                                                        <&camsys CLK_CAM2MM_GALS>;
-                                               clock-names = "cam-top", "cam0", "cam1", "cam2",
-                                                            "cam3", "cam-tm", "gals";
+                                                        <&topckgen CLK_TOP_CAM>;
+                                               clock-names = "cam0", "cam1", "cam2",
+                                                             "cam3", "gals",
+                                                             "subsys-cam-tm",
+                                                             "subsys-cam-top";
                                                mediatek,infracfg = <&infracfg_ao>;
                                                #address-cells = <1>;
                                                #size-cells = <0>;
@@ -1020,9 +1027,9 @@ power-domain@MT8186_POWER_DOMAIN_CAM_RAWA {
 
                                        power-domain@MT8186_POWER_DOMAIN_IMG {
                                                reg = <MT8186_POWER_DOMAIN_IMG>;
-                                               clocks = <&topckgen CLK_TOP_IMG1>,
-                                                        <&imgsys1 CLK_IMG1_GALS_IMG1>;
-                                               clock-names = "img-top", "gals";
+                                               clocks = <&imgsys1 CLK_IMG1_GALS_IMG1>,
+                                                        <&topckgen CLK_TOP_IMG1>;
+                                               clock-names = "gals", "subsys-img-top";
                                                mediatek,infracfg = <&infracfg_ao>;
                                                #address-cells = <1>;
                                                #size-cells = <0>;
@@ -1041,8 +1048,11 @@ power-domain@MT8186_POWER_DOMAIN_IPE {
                                                         <&ipesys CLK_IPE_LARB20>,
                                                         <&ipesys CLK_IPE_SMI_SUBCOM>,
                                                         <&ipesys CLK_IPE_GALS_IPE>;
-                                               clock-names = "ipe-top", "ipe-larb0", "ipe-larb1",
-                                                             "ipe-smi", "ipe-gals";
+                                               clock-names = "subsys-ipe-top",
+                                                             "subsys-ipe-larb0",
+                                                             "subsys-ipe-larb1",
+                                                             "subsys-ipe-smi",
+                                                             "subsys-ipe-gals";
                                                mediatek,infracfg = <&infracfg_ao>;
                                                #power-domain-cells = <0>;
                                        };
@@ -1061,7 +1071,9 @@ power-domain@MT8186_POWER_DOMAIN_WPE {
                                                clocks = <&topckgen CLK_TOP_WPE>,
                                                         <&wpesys CLK_WPE_SMI_LARB8_CK_EN>,
                                                         <&wpesys CLK_WPE_SMI_LARB8_PCLK_EN>;
-                                               clock-names = "wpe0", "larb-ck", "larb-pclk";
+                                               clock-names = "wpe0",
+                                                             "subsys-larb-ck",
+                                                             "subsys-larb-pclk";
                                                mediatek,infracfg = <&infracfg_ao>;
                                                #power-domain-cells = <0>;
                                        };
--

2.34.1

maintainer Reviewed-by Tested-by on v1 1/1
#2 lore raw
In reply to Eugen Hristev

Il 05/10/23 12:30, Eugen Hristev ha scritto:

Quoted 17 lines

Clocks for each power domain are split into big categories: pd clocks and subsys clocks.
According to the binding, all clocks which have a dash '-' in their name are treated as subsys clocks, and must be placed at the end of the list. The other clocks which are pd clocks must come first.
Fixed the naming and the placing of all clocks in the power domains. For the avoidance of doubt, prefixed all subsys clocks with the 'subsys' prefix. The binding does not enforce strict clock names, the driver uses them in bulk, only making a difference for pd clocks vs subsys clocks.

The above problem appears to be trivial, however, it leads to incorrect power up and power down sequence of the power domains, because some clocks will be mistakenly taken for subsys clocks and viceversa. One consequence is the fact that if the DIS power domain goes power down and power back up during the boot process, when it comes back up, there are still transactions left on the bus which makes the display inoperable.

Quoted 6 lines

Some of the clocks for the DIS power domain were wrongly using '_' instead of '-', which again made these clocks being treated as pd clocks instead of subsys clocks.

Fixes d9e43c1e7a38 ("arm64: dts: mt8186: Add power domains controller")
Reviewed-by on v1 1/1
#3 lore raw
In reply to Eugen Hristev
Quoted 1 line · Eugen Hristev

Clocks for each power domain are split into big categories: pd clocks and subsys clocks. According to the binding, all clocks which have a dash '-' in their name are treated as subsys clocks, and must be placed at the end of the list. The other clocks which are pd clocks must come first. Fixed the naming and the placing of all clocks in the power domains. For the avoidance of doubt, prefixed all subsys clocks with the 'subsys' prefix. The binding does not enforce strict clock names, the driver uses them in bulk, only making a difference for pd clocks vs subsys clocks. The above problem appears to be trivial, however, it leads to incorrect power up and power down sequence of the power domains, because some clocks will be mistakenly taken for subsys clocks and viceversa. One consequence is the fact that if the DIS power domain goes power down and power back up during the boot process, when it comes back up, there are still transactions left on the bus which makes the display inoperable. Some of the clocks for the DIS power domain were wrongly using '_' instead of '-', which again made these clocks being treated as pd clocks instead of subsys clocks.

Signature · 2 lines
Regards,
Alexandre
maintainer Applied
#4 lore raw
In reply to Eugen Hristev
Quoted 11 lines · Eugen Hristev

Clocks for each power domain are split into big categories: pd clocks and subsys clocks.
According to the binding, all clocks which have a dash '-' in their name are treated as subsys clocks, and must be placed at the end of the list. The other clocks which are pd clocks must come first.
Fixed the naming and the placing of all clocks in the power domains. For the avoidance of doubt, prefixed all subsys clocks with the 'subsys' prefix. The binding does not enforce strict clock names, the driver uses them in bulk, only making a difference for pd clocks vs subsys clocks.

[...]

Applied, thanks!

[1/1] arm64: dts: mediatek: mt8186: fix clock names for power domains
(no commit info)

Best regards,

Signature · 1 line
AngeloGioacchino Del Regno <[email protected]>