ocxl: fix pci device refcount leak when calling get_function_0()
Subsystems (2)
PATCH v2 1/1 ocxl: fix pci device refcount leak when calling get_function_0()
get_function_0() calls pci_get_domain_bus_and_slot(), as comment says, it returns a pci device with refcount increment, so after using it, pci_dev_put() needs be called.
Get the device reference when get_function_0() is not called, so pci_dev_put() can be called in the error path and callers unconditionally. And add comment above get_dvsec_vendor0() to tell callers to call pci_dev_put().
---
v1 -> v2:
Add comment above get_dvsec_vendor0().
Get reference where dev is function 0, and call pci_dev_put() unconditionally in callers.
--- drivers/misc/ocxl/config.c | 20 +++++++++++++++++++- 1 file changed, 19 insertions(+), 1 deletion(-)
drivers/misc/ocxl/config.c +19 -1
@@ -193,6 +193,18 @@ static int read_dvsec_vendor(struct pci_dev *dev)return 0 ; } +/** +* get_dvsec_vendor0() - Find a related PCI device (function 0) +* @dev: PCI device to match +* @dev0: The PCI device (function 0) found +* @out_pos: The position of PCI device (function 0) +* +* Returns 0 on success, negative on failure. +* +* NOTE: If it's successful, the reference of dev0 is increased, +* so after using it, the callers must call pci_dev_put() to give +* up the reference. +*/ static int get_dvsec_vendor0 (struct pci_dev *dev,struct pci_dev **dev0,int *out_pos) {
@@ -202,10 +214,14 @@ static int get_dvsec_vendor0(struct pci_dev *dev, struct pci_dev **dev0, dev =get_function_0 (dev);if (!dev)return -1 ; + }else { + dev =pci_dev_get (dev); } pos =find_dvsec (dev,OCXL_DVSEC_VENDOR_ID ); -if (!pos) +if (!pos) { +pci_dev_put (dev);return -1 ; + } *dev0 = dev; *out_pos = pos;return 0 ;
@@ -222,6 +238,7 @@ int ocxl_config_get_reset_reload(struct pci_dev *dev, int *val)pci_read_config_dword (dev0, pos +OCXL_DVSEC_VENDOR_RESET_RELOAD , &reset_reload); +pci_dev_put (dev0); *val = !!(reset_reload &BIT (0 ));return 0 ; }
@@ -243,6 +260,7 @@ int ocxl_config_set_reset_reload(struct pci_dev *dev, int val) reset_reload &= ~BIT (0 );pci_write_config_dword (dev0, pos +OCXL_DVSEC_VENDOR_RESET_RELOAD , reset_reload); +pci_dev_put (dev0);return 0 ; }
Signature · 1 line
2.25.1
Quoted 9 lines · Yang Yingliang
get_function_0()callspci_get_domain_bus_and_slot(), as comment says, it returns a pci device with refcount increment, so after using it,pci_dev_put()needs be called.Get the device reference when
get_function_0()is not called, sopci_dev_put()can be called in the error path and callers unconditionally. And add comment aboveget_dvsec_vendor0()to tell callers to callpci_dev_put().
Quoted 4 lines
Fixes 87db7579ebd5 ("ocxl: control via sysfs whether the FPGA isreloaded on a link reset")
Suggested-by Andrew Donnellan <[email protected]>Signed-off-by Yang Yingliang <[email protected]>
Looks good!
Quoted 71 lines
---
v1 -> v2:
Add comment aboveget_dvsec_vendor0().
Get reference where dev is function 0, and callpci_dev_put()unconditionally in callers.
---
drivers/misc/ocxl/config.c | 20 +++++++++++++++++++-1 file changed, 19 insertions(+), 1 deletion(-)drivers/misc/ocxl/config.c +0
-0@@ -193,6 +193,18 @@ static int read_dvsec_vendor(struct pci_dev *dev) return 0; }
+/**
+ *get_dvsec_vendor0()- Find a related PCI device (function 0)
+ * @dev: PCI device to match
+ * @dev0: The PCI device (function 0) found
+ * @out_pos: The position of PCI device (function 0)
+ *
+ * Returns 0 on success, negative on failure.
+ *
+ * NOTE: If it's successful, the reference of dev0 is increased,
+ * so after using it, the callers must callpci_dev_put()to give
+ * up the reference.
+ */
static int get_dvsec_vendor0(structpci_dev*dev, structpci_dev**dev0,
int*out_pos)
{drivers/misc/ocxl/config.c +5
-1@@ -202,10 +214,14 @@ static int get_dvsec_vendor0(struct pci_dev *dev, struct pci_dev **dev0, dev = get_function_0(dev); if (!dev) return -1; + } else { + dev = pci_dev_get(dev); } pos = find_dvsec(dev, OCXL_DVSEC_VENDOR_ID); - if (!pos) + if (!pos) { + pci_dev_put(dev); return -1; + } *dev0 = dev; *out_pos = pos;return 0;
drivers/misc/ocxl/config.c +0
-0@@ -222,6 +238,7 @@ int ocxl_config_get_reset_reload(struct pci_dev *dev, int *val)
pci_read_config_dword(dev0, pos +OCXL_DVSEC_VENDOR_RESET_RELOAD,
&reset_reload);
+ pci_dev_put(dev0);
*val = !!(reset_reload & BIT(0));
return 0;
}drivers/misc/ocxl/config.c +0
-0@@ -243,6 +260,7 @@ int ocxl_config_set_reset_reload(struct pci_dev *dev, int val) reset_reload &= ~BIT(0);pci_write_config_dword(dev0, pos +
OCXL_DVSEC_VENDOR_RESET_RELOAD,
reset_reload);
+ pci_dev_put(dev0);
return 0;
}
Signature · 2 lines
Andrew Donnellan OzLabs, ADL Canberra [email protected] IBM Australia Limited
Quoted 9 lines · Yang Yingliang
get_function_0()callspci_get_domain_bus_and_slot(), as comment says, it returns a pci device with refcount increment, so after using it,pci_dev_put()needs be called.Get the device reference when
get_function_0()is not called, sopci_dev_put()can be called in the error path and callers unconditionally. And add comment aboveget_dvsec_vendor0()to tell callers to callpci_dev_put().
Quoted 4 lines
Fixes 87db7579ebd5 ("ocxl: control via sysfs whether the FPGA is reloaded on a link reset")Suggested-by Andrew Donnellan <[email protected]>Signed-off-by Yang Yingliang <[email protected]>---
Thanks for fixing it!
Fred
Quoted 63 lines
v1 -> v2:
Add comment aboveget_dvsec_vendor0().
Get reference where dev is function 0, and callpci_dev_put()unconditionally in callers.--- drivers/misc/ocxl/config.c | 20 +++++++++++++++++++- 1 file changed, 19 insertions(+), 1 deletion(-)drivers/misc/ocxl/config.c +19
-1@@ -193,6 +193,18 @@ static int read_dvsec_vendor(struct pci_dev *dev)return 0 ; } +/** +* get_dvsec_vendor0() - Find a related PCI device (function 0) +* @dev: PCI device to match +* @dev0: The PCI device (function 0) found +* @out_pos: The position of PCI device (function 0) +* +* Returns 0 on success, negative on failure. +* +* NOTE: If it's successful, the reference of dev0 is increased, +* so after using it, the callers must call pci_dev_put() to give +* up the reference. +*/ static int get_dvsec_vendor0 (struct pci_dev *dev,struct pci_dev **dev0,int *out_pos) {@@ -202,10 +214,14 @@ static int get_dvsec_vendor0(struct pci_dev *dev, struct pci_dev **dev0, dev =get_function_0 (dev);if (!dev)return -1 ; + }else { + dev =pci_dev_get (dev); } pos =find_dvsec (dev,OCXL_DVSEC_VENDOR_ID ); -if (!pos) +if (!pos) { +pci_dev_put (dev);return -1 ; + } *dev0 = dev; *out_pos = pos;return 0 ;@@ -222,6 +238,7 @@ int ocxl_config_get_reset_reload(struct pci_dev *dev, int *val)pci_read_config_dword (dev0, pos +OCXL_DVSEC_VENDOR_RESET_RELOAD , &reset_reload); +pci_dev_put (dev0); *val = !!(reset_reload &BIT (0 ));return 0 ; }@@ -243,6 +260,7 @@ int ocxl_config_set_reset_reload(struct pci_dev *dev, int val) reset_reload &= ~BIT (0 );pci_write_config_dword (dev0, pos +OCXL_DVSEC_VENDOR_RESET_RELOAD , reset_reload); +pci_dev_put (dev0);return 0 ; }
Michael Ellerman
AppliedQuoted 10 lines · Yang Yingliang
get_function_0()callspci_get_domain_bus_and_slot(), as comment says, it returns a pci device with refcount increment, so after using it,pci_dev_put()needs be called.Get the device reference when
get_function_0()is not called, sopci_dev_put()can be called in the error path and callers unconditionally. And add comment aboveget_dvsec_vendor0()to tell callers to callpci_dev_put().[...]
Applied to powerpc/next.
[1/1] ocxl: fix pci device refcount leak when calling get_function_0()
https://git.kernel.org/powerpc/c/5f58cad1e4c65bebee34292696c6d2105eeb2027
cheers