PATCH 1/1 Fix cleanup when VAS is not configured

From: Sukadev Bhattiprolu <[email protected]>
Date: Fri, 9 Feb 2018 11:49:06 -0600
Subject: [PATCH 1/1] powerpc/vas: Fix cleanup when VAS is not configured

When VAS is not configured, unregister the platform driver. Also simplify cleanup by delaying vas debugfs init until we know VAS is configured.

---
Changelog[v2]
- [Michael Ellerman] Move vas_init_dbgdir() into a lower level function to keep vas_init() cleaner.

---
 arch/powerpc/platforms/powernv/vas-debug.c | 11 +++++++++++
 arch/powerpc/platforms/powernv/vas.c       |  6 +++---
 2 files changed, 14 insertions(+), 3 deletions(-)
arch/powerpc/platforms/powernv/vas-debug.c +11 -0
index b4de4c6..4f7276e 100644
@@ -179,6 +179,7 @@ void vas_instance_init_dbgdir(struct vas_instance *vinst)
 {
 	struct dentry *d;
 
+	vas_init_dbgdir();
 	if (!vas_debugfs)
 		return;
 
@@ -201,8 +202,18 @@ void vas_instance_init_dbgdir(struct vas_instance *vinst)
 	vinst->dbgdir = NULL;
 }
 
+/*
+ * Set up the "root" VAS debugfs dir. Return if we already set it up
+ * (or failed to) in an earlier instance of VAS.
+ */
 void vas_init_dbgdir(void)
 {
+	static bool first_time = true;
+
+	if (!first_time)
+		return;
+
+	first_time = false;
 	vas_debugfs = debugfs_create_dir("vas", NULL);
 	if (IS_ERR(vas_debugfs))
 		vas_debugfs = NULL;
arch/powerpc/platforms/powernv/vas.c +3 -3
index aebbe95..5a2b24c 100644
@@ -160,8 +160,6 @@ static int __init vas_init(void)
 	int found = 0;
 	struct device_node *dn;
 
-	vas_init_dbgdir();
-
 	platform_driver_register(&vas_driver);
 
 	for_each_compatible_node(dn, NULL, "ibm,vas") {
@@ -169,8 +167,10 @@ static int __init vas_init(void)
 		found++;
 	}
 
-	if (!found)
+	if (!found) {
+		platform_driver_unregister(&vas_driver);
 		return -ENODEV;
+	}
 
 	pr_devel("Found %d instances\n", found);
 
Signature · 1 line
2.7.4
#1 lore raw
Quoted 8 lines · Sukadev Bhattiprolu

From: Sukadev Bhattiprolu <[email protected]>
Date: Fri, 9 Feb 2018 11:49:06 -0600
Subject: [PATCH 1/1] powerpc/vas: Fix cleanup when VAS is not configured

When VAS is not configured, unregister the platform driver. Also simplify cleanup by delaying vas debugfs init until we know VAS is configured.

Applied to powerpc next, thanks.

https://git.kernel.org/powerpc/c/45ddea8a73a25461387eb8e87f3e0e