synchronous serial port communication (16550A)
A message that is not in the archive (sent off-list or not yet received): [email protected]
A message that is not in the archive (sent off-list or not yet received): [email protected]
Quoted 4 lines · Miquel van Smoorenburg
Why don't you simply turn on hardware flow control (i.e. enable CRTSCTS with
tcsetattr()or even stty) ?Mike.
RTS has a special meaning with this lcd-controller, so I don't want that it is set without my implicit will.
A message that is not in the archive (sent off-list or not yet received): [email protected]
Quoted 2 lines · Russell King
You could write a byte, wait for it to complete by calling ioctl(TCSETSW) without changing any parameters, and then read the CTS status.
I'm away for 2 days now, so I will try it when I will be back home. Thank you!
--
Regards,
Christof Krueger