I setup a similar system on a HDS-9570 but with only one card in each machine - 'assuming' that the failover in the driver would cope if a controller on the HDS failed (as opposed to a QLogic failure)

This worked fine if I disconncected a path in the fabric but when we took a controller of line the failover failed.

Since then I have used md multipath which has tested fine

I have a similar issue, two storage processors, two HBAs, and redundant paths between them.

On the host, I see 4 SCSI devices, two valid, two invalid - I'm guessing this is caused because only one storage processor exports a particular LUN, so half the paths are invalid until a storage processor fails over.

sdd - SP A Path 1
sde - SP B Path 1
sdf - SP A Path 2
sdg - SP B Path 2

I have a LUN currently on SP B, so I can use md multipath configured with /dev/sde and /dev/sdg, and that seems to work.

However, two things:

1) How do I set this up to handle a failover to SP A?
2) Multipath only seems to work in failover mode, is there a way to load balance across the two paths?

Anyone have any hints? :)

#1 lore raw
Quoted 13 lines · Cott Lang

On the host, I see 4 SCSI devices, two valid, two invalid - I'm guessing this is caused because only one storage processor exports a particular LUN, so half the paths are invalid until a storage processor fails over.

sdd - SP A Path 1
sde - SP B Path 1
sdf - SP A Path 2
sdg - SP B Path 2

I have a LUN currently on SP B, so I can use md multipath configured with /dev/sde and /dev/sdg, and that seems to work.

Quoted 7 lines

However, two things:

1) How do I set this up to handle a failover to SP A?
2) Multipath only seems to work in failover mode, is there a way to load balance across the two paths?

Anyone have any hints? :)

Hello Cott,

your questions and the phenomena you see are likely to be specific to your hardware. I tried Emulex and QLogic HBA and found very different behaviour.

Multipathing is handled by the storage systems differently from dumb disks. Load balancing over several physical paths is therefore a complicated task. Most vendors do not really support it. Some systems suffer from a Host switching paths. Unless you do not use a supported (read: expensive) Software you should keep your hands off.

Even failover has a 'mechanical' quality: you can hear the door's angles squiek when it happens.
I found my clusters diving after teardown of a storage's HBA.

Failover while switching the physical path, i.e. switching the HBA takes at least 45 second on a (tuned) qlogic. Meanwhile the whole computer freezes. The driver seems to switch off interrupts or something.

Have fun finding your solution.