2.6.11-rc4 md loops on missing drives
G'day all,
I have just finished my shiny new RAID-6 box. 15 x 250GB SATA drives.
While doing some failure testing (inadvertently due to libata SMART causing command errors) I dropped 3 drives out of the array in sequence.
md coped with the first two (as it should), but after the third one dropped out I got the below errors spinning continuously in my syslog until I managed to stop the array with mdadm --stop /dev/md0
I'm not really sure how it's supposed to cope with losing more disks than planned, but filling the syslog with nastiness is not very polite.
This box takes _ages_ (like between 6 an 10 hours) to rebuild the array, but I'm willing to run some tests if anyone has particular RAID-6 stuff they want tested before I put it into service. I do plan on a couple of days burn-in testing before I really load it up anyway.
The last disk is missing at the moment as I'm short one disk due to a Maxtor dropping its bundle after about 5000 hours.
I'm using todays BK kernel plus the libata and libata-dev trees. The drives are all on Promise SATA150TX4 controllers.
Feb 15 17:58:28 storage1 kernel: .<6>md: syncing RAID array md0 Feb 15 17:58:28 storage1 kernel: md: minimum _guaranteed_ reconstruction speed: 1000 KB/sec/disc. Feb 15 17:58:28 storage1 kernel: md: using maximum available idle IO bandwith (but not more than 200000 KB/sec) for reconstruction. Feb 15 17:58:28 storage1 kernel: md: using 128k window, over a total of 245117312 blocks. Feb 15 17:58:28 storage1 kernel: md: md0: sync done. Feb 15 17:58:28 storage1 kernel: .<6>md: syncing RAID array md0 Feb 15 17:58:28 storage1 kernel: md: minimum _guaranteed_ reconstruction speed: 1000 KB/sec/disc. Feb 15 17:58:28 storage1 kernel: md: using maximum available idle IO bandwith (but not more than 200000 KB/sec) for reconstruction. Feb 15 17:58:28 storage1 kernel: md: using 128k window, over a total of 245117312 blocks. Feb 15 17:58:28 storage1 kernel: md: md0: sync done. Feb 15 17:58:28 storage1 kernel: .<6>md: syncing RAID array md0 Feb 15 17:58:28 storage1 kernel: md: minimum _guaranteed_ reconstruction speed: 1000 KB/sec/disc. Feb 15 17:58:28 storage1 kernel: md: using maximum available idle IO bandwith (but not more than 200000 KB/sec) for reconstruction. Feb 15 17:58:28 storage1 kernel: md: using 128k window, over a total of 245117312 blocks. Feb 15 17:58:28 storage1 kernel: md: md0: sync done. Feb 15 17:58:28 storage1 kernel: .<6>md: syncing RAID array md0 Feb 15 17:58:28 storage1 kernel: md: minimum _guaranteed_ reconstruction speed: 1000 KB/sec/disc. Feb 15 17:58:28 storage1 kernel: md: using maximum available idle IO bandwith (but not more than 200000 KB/sec) for reconstruction. Feb 15 17:58:28 storage1 kernel: md: using 128k window, over a total of 245117312 blocks. Feb 15 17:58:28 storage1 kernel: md: md0: sync done. Feb 15 17:58:28 storage1 kernel: .<6>md: syncing RAID array md0 Feb 15 17:58:28 storage1 kernel: md: minimum _guaranteed_ reconstruction speed: 1000 KB/sec/disc. Feb 15 17:58:28 storage1 kernel: md: using maximum available idle IO bandwith (but not more than 200000 KB/sec) for reconstruction.
<to infinity and beyond>
Existing raid config below. Fail any additional 2 drives due to IO errors to cause this issue.
storage1:/home/brad# mdadm --detail /dev/md0
/dev/md0:
Version : 00.90.01
Creation Time : Tue Feb 15 22:00:16 2005
Raid Level : raid6
Array Size : 3186525056 (3038.91 GiB 3263.00 GB)
Device Size : 245117312 (233.76 GiB 251.00 GB)
Raid Devices : 15
Total Devices : 15
Preferred Minor : 0
Persistence : Superblock is persistent Update Time : Tue Feb 15 17:17:36 2005
State : clean, degraded, resyncing
Active Devices : 14
Working Devices : 14
Failed Devices : 1
Spare Devices : 0
Chunk Size : 128K
Rebuild Status : 0% complete
UUID : 11217f79:ac676966:279f2816:f5678084
Events : 0.40101
Number Major Minor RaidDevice State
0 8 0 0 active sync /dev/devfs/scsi/host0/bus0/target0/lun0/disc
1 8 16 1 active sync /dev/devfs/scsi/host1/bus0/target0/lun0/disc
2 8 32 2 active sync /dev/devfs/scsi/host2/bus0/target0/lun0/disc
3 8 48 3 active sync /dev/devfs/scsi/host3/bus0/target0/lun0/disc
4 8 64 4 active sync /dev/devfs/scsi/host4/bus0/target0/lun0/disc
5 8 80 5 active sync /dev/devfs/scsi/host5/bus0/target0/lun0/disc
6 8 96 6 active sync /dev/devfs/scsi/host6/bus0/target0/lun0/disc
7 8 112 7 active sync /dev/devfs/scsi/host7/bus0/target0/lun0/disc
8 8 128 8 active sync /dev/devfs/scsi/host8/bus0/target0/lun0/disc
9 8 144 9 active sync /dev/devfs/scsi/host9/bus0/target0/lun0/disc
10 8 160 10 active sync /dev/devfs/scsi/host10/bus0/target0/lun0/disc
11 8 176 11 active sync /dev/devfs/scsi/host11/bus0/target0/lun0/disc
12 8 192 12 active sync /dev/devfs/scsi/host12/bus0/target0/lun0/disc
13 8 208 13 active sync /dev/devfs/scsi/host13/bus0/target0/lun0/disc
14 0 0 - removed
15 8 224 - faulty /dev/devfs/scsi/host14/bus0/target0/lun0/disc
Regards,
Brad
Signature · 3 lines
"Human beings, who are almost unique in having the ability to learn from the experience of others, are also remarkable for their apparent disinclination to do so." -- Douglas Adams
Quoted 4 lines · On Tuesday February 15, [email protected] wrote:
G'day all,
I'm not really sure how it's supposed to cope with losing more disks than planned, but filling the syslog with nastiness is not very polite.
Thanks for the bug report. There are actually a few problems relating to resync/recovery when an array (raid 5 or 6) has lost too many devices.
This patch should fix them.
NeilBrown
------------------------------------------------
Make raid5 and raid6 robust against failure during recovery.
Two problems are fixed here.
1/ if the array is known to require a resync (parity update),
but there are too many failed devices, the resync cannot complete but will be retried indefinitedly.
2/ if the array has two many failed drives to be usable and a spare is
available, reconstruction will be attempted, but cannot work. This also is retried indefinitely.
### Diffstat output
./drivers/md/md.c | 12 ++++++------ ./drivers/md/raid5.c | 13 +++++++++++++ ./drivers/md/raid6main.c | 12 ++++++++++++ 3 files changed, 31 insertions(+), 6 deletions(-)
drivers/md/md.c renamed from drivers/md/md.c~current~ +6 -6
@@ -3655,18 +3655,18 @@ void md_check_recovery(mddev_t *mddev)/* no recovery is running. * remove any failed drives, then -* add spares if possible +* add spares if possible. +* Spare are also removed and re-added, to allow +* the personality to fail the re-add. */ - ITERATE_RDEV(mddev,rdev,rtmp) { + ITERATE_RDEV(mddev,rdev,rtmp)if (rdev->raid_disk >=0 && - rdev->faulty && + (rdev->faulty || ! rdev->in_sync) &&atomic_read (&rdev->nr_pending)==0 ) {if (mddev->pers->hot_remove_disk (mddev, rdev->raid_disk)==0 ) rdev->raid_disk =-1 ; } -if (!rdev->faulty && rdev->raid_disk >=0 && !rdev->in_sync) - spares++; - } +if (mddev->degraded) {ITERATE_RDEV (mddev,rdev,rtmp) if (rdev->raid_disk < 0
drivers/md/raid5.c renamed from drivers/md/raid5.c~current~ +13 -0
@@ -1491,6 +1491,15 @@ static int sync_request (mddev_t *mddev,unplug_slaves (mddev);return 0 ; } +/* if there is 1 or more failed drives and we are trying +* to resync, then assert that we are finished, because there is +* nothing we can do. +*/ +if (mddev->degraded >=1 &&test_bit (MD_RECOVERY_SYNC , &mddev->recovery)) { +int rv = (mddev->size <<1 ) - sector_nr; +md_done_sync (mddev, rv,1 ); +return rv; + } x = sector_nr; chunk_offset =sector_div (x, sectors_per_chunk);
@@ -1882,6 +1891,10 @@ static int raid5_add_disk(mddev_t *mddevint disk;struct disk_info *p; +if (mddev->degraded >1 ) +/* no point adding a device */ +return 0 ; +/* * find the disk ... */
drivers/md/raid6main.c renamed from drivers/md/raid6main.c~current~ +12 -0
@@ -1650,6 +1650,15 @@ static int sync_request (mddev_t *mddev,unplug_slaves (mddev);return 0 ; } +/* if there are 2 or more failed drives and we are trying +* to resync, then assert that we are finished, because there is +* nothing we can do. +*/ +if (mddev->degraded >=2 &&test_bit (MD_RECOVERY_SYNC , &mddev->recovery)) { +int rv = (mddev->size <<1 ) - sector_nr; +md_done_sync (mddev, rv,1 ); +return rv; + } x = sector_nr; chunk_offset =sector_div (x, sectors_per_chunk);
@@ -2048,6 +2057,9 @@ static int raid6_add_disk(mddev_t *mddevint disk;struct disk_info *p; +if (mddev->degraded >2 ) +/* no point adding a device */ +return 0 ;/* * find the disk ... */
Quoted 4 lines · Neil Brown
Quoted 2 lines · On Tuesday February 15, [email protected] wrote:
G'day all,
Quoted 8 lines
Quoted 1 line
I'm not really sure how it's supposed to cope with losing more disks than planned, but filling the syslog with nastiness is not very polite.
Thanks for the bug report. There are actually a few problems relating to resync/recovery when an array (raid 5 or 6) has lost too many devices.
This patch should fix them.
I applied your latest array of 9 patches to a vanilla BK kernel and did very, very horrible things to it while it was rebuilding. I can confirm that it does indeed tidy up the resync issues.
Ta!
Brad
Signature · 3 lines
"Human beings, who are almost unique in having the ability to learn from the experience of others, are also remarkable for their apparent disinclination to do so." -- Douglas Adams